• 제목/요약/키워드: Dual-Energy

검색결과 1,051건 처리시간 0.026초

Numerical Feasibility Study for a Spaceborne Cooler Dual-function Energy Harvesting System

  • Kwon, Seong-Cheol;Oh, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.579-587
    • /
    • 2017
  • Spaceborne cryocoolers produce undesirable micro-vibration disturbances during their on-orbit operation, which are a primary source of image-quality degradation for high-resolution observation satellites. Therefore, to comply with the strict mission requirement of high-quality image acquisition, micro-vibration disturbances induced by cooler operation have always been subjected to an isolation objective. However, in this study, we focused on the applicability of energy harvesting technology to generate electrical energy from micro-vibration energy of the cooler and investigated the feasibility of utilizing harvested energy as a power source to operate low-power-consumption devices such as micro-electromechanical system (MEMS) devices. A tuned mass damper (TMD)-type electromagnetic energy harvester combined with a conventional passive vibration isolator was proposed to achieve this objective. The system performs the dual functions of electrical energy generation and micro-vibration isolation. The effectiveness of the strategy was evaluated through numerical simulations.

수정체 차페로 기인한 화질저하 개선을 위한 듀얼 에너지 CT의 유용성 (Usefulness of Dual Energy CT to Improve Image Quality Degradation due to Lens Shielding)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.969-977
    • /
    • 2019
  • 방사선 피폭감소를 위해 사용하는 비스무스 차폐체를 적용하여 CT스캔 시 차폐체에 의한 선속경화현상으로 화질이 감소되는 경우가 있다. 이에 G사의 듀얼 에너지 CT의 GSI모드 적용을 통해 화질저하 현상을 줄일 수 있는 에너지 영역대를 찾아보고, 가능성을 실험을 통해 알아보고자 하였다. 그 결과 비스무스 차폐 후 듀얼 에너지 CT 스캔 시 50 keV에서 118±10.6 HU, 50.1±14.6 HU로 화질저하 전 CT value와 가장 유사하였고(p>0.05), Image J의 Multi-point기능을 적용한 Pixel value에서도 50 keV에서 176.6±7.1, 138.3±1.1로 측정 되었다(p>0.05). CT검사 시 차폐체의 사용은 불가항력적으로 화질저하를 유발하지만 듀얼 에너지 CT의 GSI기능 적용으로 차폐체를 사용하고도 화질을 유지할 수 있다는 것을 실험을 통해 알 수 있었다. 향후 다양한 차폐체를 듀얼 에너지 CT를 이용, 평가 후 보안 한다면 CT검사의 최대 단점인 피폭 감소를 위한 방사선 차폐체 사용으로 발생한 화질저하라 단점을 극복할 수 있을 것으로 기대된다.

몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리 (Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation)

  • 엄지수;강순철;이승완
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.443-451
    • /
    • 2017
  • 유방촬영술은 유방암의 조기검진을 위해 시행되는 대표적인 검사이다. 하지만 유방 구성물질의 물리적 특성에 의존하는 유방촬영상은 병변의 악성 또는 양성 여부에 대한 정보 제공이 불가능하다. 이중에너지 영상 감산법을 시행하는 경우 유방촬영상에서 특정 물질에 대한 정보를 추출할 수 있지만 피폭선량을 증가시킬 뿐만 아니라 물질분리의 정확도를 감소시키는 단점이 있다. 본 연구에서는 물질의 선감약계수를 적용한 유방팬텀을 모사하여 광자계수검출기 기반 이중에너지 유방촬영에서 특정 물질에 대한 가중함수를 적용하여 분리의 정확도를 향상시킬 수 있는 기술을 제안하였다. 그리고 유방팬텀영상으로부터 물질분리의 정확도를 평가하기 위해 대조도 및 잡음 특성을 분석하였다. 분석 결과 이중에너지 가중 영상 감산법의 악성종양에 대한 대조도는 일반적인 유방촬영과 이중에너지 영상 감산법에 비해 각각 0.98, 1.06배로 큰 차이가 없다. 그렇지만 이중에너지 가중 영상 감산법 적용 시 양성종양에 대한 대조도가 0에 근사하기 때문에 양성종양에 대한 악성종양의 상대적인 대조도가 13.54배로 크게 향상된 것으로 확인되었다. 따라서 본 연구에서 제안하는 이중에너지 가중 영상 감산법은 유방촬영 진단의 정확도 향상에 기여할 수 있을 것이다.

진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구 (An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod)

  • 오상훈;최광용;유홍식;김영주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.91-100
    • /
    • 2018
  • 본 연구에서 제안하는 내진보강기법은 듀얼시스템으로 비내진상세로 설계된 저층구조물을 대상으로 적용하기 위한 기법이다. 듀얼시스템은 기존의 구조체, 외부보강체, 강재이력댐퍼로 구성되고 구조체와 외부보강체 사이에 강재이력댐퍼를 설치한다. 구조체와 외부보강체는 강성과 적재하중에 의해 서로 다른 주기에 의해 상대변위가 발생되고 강재이력댐퍼를 통해 지진에너지를 흡수한다. 본 연구에서 제안된 듀얼시스템의 내진성능을 검증하기 위해 동적실험을 수행한다. 동적 실험결과, 듀얼시스템 보강 시 에너지가 1.84배 더 많이 입력됨에도 불구하고 56%의 변형 저감과, 93%의 손상 저감이 됨에 따라 듀얼시스템 적용 시 내진성능을 향상시킬 것으로 판단된다. 그리고 연구결과는 듀얼시스템의 설계범위를 설정하기 위한 추후 연구의 기초자료로 제시하고자 한다.

에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가 (Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device)

  • 주은빈;안소현;조삼주;금기창;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구에서는 이중에너지 영상을 획득하는 방법으로, 구리판을 이용한 에너지 변조 필터를 사용하였을 때의 선량을 계산 및 측정하였고, 기존의 다른 방법들과 선량을 비교하였다. 몬테칼로 전산모사를 이용하여 에너지 변조 필터에 의한 선량 변화를 평가하기 위하여 MCNPX를 사용하였다. 두경부, 흉부, 복부 촬영에 주로 사용되는 관전압인 80, 120 kVp에 대한 스펙트럼을 SPEC78 프로그램으로 생성하여 선원을 모사하였고, 구리 물질로 이루어진 에너지 변조 필터(밀도: $8.96g/cm^3$)는 두께를 0.5 mm부터 2.0 mm까지 0.5 mm 간격으로 변화시켜가면서 선원으로부터 20.0 cm 거리에 X-선 창을 절반만 가리도록 모델링 하였다. 몬테칼로 전산모사 값과 실제 선량 값을 비교하기 위해서는 교정 상수가 필요하므로, Gafchromic EBT3 필름에 알고 있는 선량을 조사한 후 판독하여 선량 교정 곡선을 획득하였다. 실험과 동일한 조건으로 MCNPX의 f6 tally로 획득한 결과값과 측정값 간의 선량 환산 인자는 $7.2*10^4cGy/output$으로 구해졌으며, 관전압 80 kVp과 관전류 6 mA의 조건으로 콘빔 CT 촬영 시, 평균 10.1 cGy (표준편차 2.7 cGy) 조사됨을 알 수 있었다. 에너지 변조 필터에 기반한 이중 에너지 영상 획득 기술을 적용한 본 연구에서는 이중 에너지 콘빔 CT 시스템의 선량이 단일 에너지 CT 시스템의 선량보다 33~40% 감소함을 알 수 있다. 또한, 에너지 변조 필터에서 발생한 산란선에 의한 선량 증가 효과는 거의 없었다. 따라서, 인체 내 물질 분별력이 우수하여 임상에 널리 응용되었던 기존 이중 에너지 CT 시스템의 상대적으로 피폭선량이 높다는 단점을 효과적으로 개선할 수 있다.

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

Split-Capacitor Dual-Active-Bridge 컨버터 (Split-Capacitor Dual-Active-Bridge Converter)

  • 김기수;박시호;차헌녕;최병조
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.352-358
    • /
    • 2018
  • A split-capacitor (SC) dual-active-bridge (DAB) converter is proposed in this study. The DC-link capacitors of input and output are split in the proposed converter. The primary and secondary windings of transformer are connected to the midpoints of the DC-links. Hence, the SC DAB converter can inherently prevent transformer from saturation. Although the switch current stress of the proposed converter is twice that of the conventional DAB converter, the switch voltage stress is reduced by half. Therefore, the proposed converter can reduce switching loss and achieve high efficiency in a high switching frequency. Given the SC structure, the proposed converter can readily be connected to neutral-point-clamped- or half-bridge-type converters. The topology of the proposed converter is presented and the operating principle is analyzed in detail. A 3-kW hardware prototype was built and tested to verify the performance of the proposed converter.

비대칭 환경에서 듀얼홉 통신시스템의 자원할당 성능분석 (Performance Analysis of Resource Allocation in Asymmetric dual-hop Communication System)

  • 조웅
    • 한국전자통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.655-660
    • /
    • 2024
  • 통신시스템에서 중계기는 전체 시스템의 성능을 향상시키는 장점으로 인해 다양한 통신환경에서 적용되어져 왔다. 본 논문에서는 하나의 중계기를 이용하는 듀얼홉 통신시스템에서 비대칭 통신 시나리오를 고려한 시스템의 성능을 분석한다. 성능분석은 비트오류율을 사용한다. 먼저 대칭 환경과 비대칭 환경에서의 전체 성능을 비교하고 자원할당에 따른 성능을 분석한다. 자원할당은 에너지 할당과 중계기 위치 할당을 고려한다. 에너지 할당과 중계기 위치에 따른 성능을 각각 분석하고 두 가지 자원을 동시에 고려했을 경우에 대한 성능 또한 분석한다. 성능분석을 기반으로 하여 대칭 환경과 비대칭 환경에서의 자원할당 효과에 대해 논의한다.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.