• Title/Summary/Keyword: Dual wavelength

Search Result 127, Processing Time 0.028 seconds

Energy-band model on photoresponse transitions in biased asymmetric dot-in-double-quantum-well infrared detector

  • Sin, Hyeon-Uk;Choe, Jeong-U;Kim, Jun-O;Lee, Sang-Jun;No, Sam-Gyu;Lee, Gyu-Seok;Krishna, S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.234-234
    • /
    • 2010
  • The PR transitions in asymmetric dot-in-double-quantum-well (DdWELL) photodetector is identified by bias-dependent spectral behaviors. Discrete n-i-n infrared photodetectors were fabricated on a 30-period asymmetric InAs-QD/[InGaAs/GaAs]/AlGaAs DdWELL wafer that was prepared by MBE technique. A 2.0-monolayer (ML) InAs QD ensemble was embedded in upper combined well of InGaAs/GaAs and each stack is separated by a 50-nm AlGaAs barrier. Each pixel has circular aperture of 300 um in diameter, and the mesa cell ($410{\times}410\;{\mu}m^2$) was defined by shallow etching. PR measurements were performed in the spectral range of $3{\sim}13\;{\mu}m$ (~ 100-400 meV) by using a Fourier-transform infrared (FTIR) spectrometer and a low-noise preamplifier. The asymmetric photodetector exhibits unique transition behaviors that near-/far-infrared (NIR/FIR) photoresponse (PR) bands are blue/red shifted by the electric field, contrasted to mid-infrared (MIR) with no dependence. In addition, the MIR-FIR dual-band spectra change into single-band feature by the polarity. A four-level energy band model is proposed for the transition scheme, and the field dependence of FIR bands numerically calculated by a simplified DdWELL structure is in good agreement with that of the PR spectra. The wavelength shift by the field strength and the spectral change by the polarity are discussed on the basis of four-level transition.

  • PDF

Studies on the Analysis of Constituents of Deer Horn(I) -Assay of Trace Elements and TLC Pattern Analysis of Gangliosides- (산지별 녹용(鹿茸)류의 성분분석 연구(I) -미량금속의 정량 및 Gangliosides의 TLC Pattern 분석-)

  • Hong, Nam-Doo;Won, Do-Hee;Kim, Nam-Jae;Chang, Seung-Youb;Youn, Whang-Geum;Kim, Hae-Soo
    • Korean Journal of Pharmacognosy
    • /
    • v.22 no.3
    • /
    • pp.171-182
    • /
    • 1991
  • Several experiments were carried for the purpose of establishing the basis for the quality evaluation of deer horn. Deer horn originated from China, New Zealand, Soviet and Alaska were used as objectives and some constituents involved in deer horn were assayed and compared with one another. Five kinds of trace elements including Ca and Fe were determined by atomic absorbance spectroscopy. The more the region came down from the top of the deer horn, the more the ratio of Ca to Fe content (Ca/Fe) was increased. The same increasing tendancy was observed in the case of ash content. Gangliosides were isolated from deer horn by alumina column chromatography and identified by TLC using gangliosides Type II obtained from bovine brain as the standard material. The TLC chromatograms were scanned by dual wavelength TLC scanner, then those TLC profiles were compared. Deer horn from China and New Zealand were analogous but those from Soviet and Alaska were each distinguished in their TLC profiles.

  • PDF

Analysis of Polarization and Beam Tilt Characteristics of Single Arm Spiral Antenna by Varying Length and Feed (한팔 나선 안테나의 길이 및 급전 변화에 따른 편파 및 빔 틸트 특성에 대한 분석)

  • Yang, Chan-Woo;Park, Se-Hyun;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3137-3143
    • /
    • 2009
  • In this paper, a single arm spiral antenna has been investigated about the characteristics of polarization and tilt beam. If a circumference length of spiral is bigger than a wavelength, it have a characteristic of varying maximum radiation beam direction. In addition, circular polarizations (RHCP, LHCP) can be variable by the feeding points (inner, outer). Also maximum beam directions tilt in different direction according to the circular polarizations, LHCP and RHCP. These characteristics of single arm spiral antenna are able to apply in the beam forming, diversity, MIMO application which has dual polarization using an antenna element.

Study of LST Surface Modification effect on friction and wear at lubricating condition

  • Tripathi, Khagendra;Joshi, Bhupendra;Gyawali, Gobinda;Kim, Seung-Ho;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.182-183
    • /
    • 2014
  • Hemispherical dimples with diameter, ø=$60{\mu}m$ and depth, d= $30{\mu}m$ were created on the metal and ceramics surfaces using INYA 10 watt Laser of 1064 nm wavelength. This study reports the influence of dimple pitch on friction and wear behavior rather than dimple size, depth and density. LST was performed on the specimens with dimple pitch and density in the range of 80 to-$200{\mu}m$ and 44 to 7 %, respectively. Surface topography was analyzed by using roughness measurement, scanning electron microscopy (SEM), and optical microscopy. Friction and wear characteristics were analyzed on textured surfaces at lubricating environment to observe the effect of surface texturing on reduction of friction and wear. Reduction on coefficient of friction was achieved by more than 70% due to the dual behavior of dimples as wear (debris) traps and lubricant reservoirs. Wear reduced significantly for the textured surface as compared to the polished surface. Moreover, the friction coefficient of the textured specimens reduced with increasing load and speed which may be attributed to the transition of lubrication regime.

  • PDF

Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

  • Lima, Adriano Fonseca;Formaggio, Stephanie Ellen Ferreira;Zambelli, Ligia Franca Aires;Palialol, Alan Rodrigo Muniz;Marchi, Giselle Maria;Saraceni, Cintia Helena Coury;de Oliveira, Marcelo Tavares
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.271-277
    • /
    • 2016
  • Objectives: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. Materials and Methods: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and $20J/cm^2$) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length ${\times}$ 2 mm in width ${\times}$ 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. Results: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

FUV observation of the comet C/2001 Q4 (NEAT) with FIMS

  • Lim, Yeo-Myeong;Min, Kyoung Wook;Feldman, Paul D.;Han, Wonyong;Edelstein, Jerry
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.107.1-107.1
    • /
    • 2012
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual-channel imaging spectrograph (S channel 900-1150 ${\AA}$, L channel 1350-1750 ${\AA}$, ${\lambda}/{\Delta}{\lambda}$ ~ 550) with large image fields of view (S: $4^{\circ}.0{\times}4^{\prime}.6$, L: $7^{\circ}.5{\times}4^{\prime}.3$, angular resolution 5'-10') optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) was observed with a scanning survey mode when it was located around the perihelion between 8 and 15 May 2004. Several important emission lines were detected including S I (1425, 1474 ${\AA}$), C I (1561, 1657 ${\AA}$) and several emission lines of CO $A^1{\Pi}-X^1{\Sigma}^+$ system in the L channel. Production rates of the notable molecules, such as C I, S I and CO, were estimated from the photon fluxes of these spectral lines and compared with previous observations. We compare the flux and the production rates in the radius of $3{\times}10^5$ km with $20{\times}10^5$ km from the central coma. We obtained L-channel image which have map size $5^{\circ}{\times}5^{\circ}$ The image was constructed for the wavelength band of L-channel (1350 - 1710 ${\AA}$. We also present the radial profiles of S I, C I, CO obtained from the spectral images of the central coma. The radial profiles of $2{\times}10^6$ km region are compared with the Haser model.

  • PDF

Electrical, optical, and structural properties of IZTO films grown by co-sputtering method using ITO and IZO target (ITO와 IZO 타겟의 Co-sputtering 방법으로 성장시킨 IZTO 박막의 전기적 광학적 구조적 특성연구)

  • Jeong, Jin-A;Choi, Kwang-Hyuk;Moon, Jong-Min;Bae, Jung-Hyeok;Kim, Han-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.379-380
    • /
    • 2007
  • The characteristics of a co-sputtered indium zinc tin oxide (IZTO) films prepared by dual target dc magnetron sputtering from IZO and ITO targets at a room temperature are investigated. Film properties, such as sheet resistance, optical transmittance, surface work function and surface roughness were examined as a function of ITO dc power at constant IZO dc power of 100 W. It was shown that the increase of the ITO dc power during co-sputtering of ITO and IZO target resulted in an increase of sheet resistance of the IZTO films. This can be attributed to high resistivity of ITO film prepared at room temperature. Surface smoothness and roughness were investigated by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The synchrotron x-ray scattering results obtained from IZTO film with different ITO contents showed that introduction of ITO atoms into amorphous IZO film resulted in a crystallization of IZTO film with (222) preferred orientation due to low alc transition temperature of ITO film. However, the transmittance of the IZTO films with thickness of 150 nm is between 80 and 85 % at wavelength of 550 nm regardless of ITO content. Possible mechanism to explain the ITO and IZO co-sputtering effect on properties of IZTO is suggested.

  • PDF

Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device (휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발)

  • Gyoung-Hahn Kim;Seong-Woo Woo;Sung Hun Ha;Jinlong Piao;MD Sahin Sarker;Baejeong Park;Chang-Sei Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.

The Far-ultraviolet Spectrum Study of Comet C/2001 Q4 (NEAT)

  • Lim, Yeo-Myeong;Min, Kyoung-Wook;Feldman, Paul D.;Han, Wanyong;Edelstein, Jerry
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.68.1-68.1
    • /
    • 2014
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual channel imaging spectrograph (S-channel 900-1150 ${\AA}$, L-channel 1350-1710 ${\AA}$, and ${\lambda}/{\Delta}{\lambda}$ ~ 550 for both channels) with large image fields of view (S-channel $4.0^{\circ}{\times}4.6^{\prime}$, L-channel $7.5^{\circ}{\times}4.3^{\prime}$, and angular resolution ~ $5-10^{\prime}$) optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) were made in two campaigns during its perihelion approach between May 8 and 15, 2004. Based on the scanning mode observations in the wavelength band of 1400-1700 ${\AA}$, we have constructed an image of the comet with an angular size of $5^{\circ}{\times}5^{\circ}$, which corresponds to the central coma region. Several important fluorescence emission lines were detected including S I multiplets at 1429 and 1479 ${\AA}$, C I multiplets at 1561 and 1657 ${\AA}$, and the CO $A^1{\Pi}-X^1{\Sigma}^+$ Fourth Positive system; we have estimated the production rates of the corresponding species from the fluxes of these emission lines. The estimated production rate of CO was $Q_{CO}=(2.65{\pm}0.63){\times}10^{28}s^{-1}$, which is 6.2-7.4% of the water production rate and is consistent with earlier predictions. The average carbon production rate was estimated to be $Q_C={\sim}1.59{\times}10^{28}s^{-1}$, which is ~60% of the CO production rate. However, the observed carbon profile was steeper than that predicted using the two-component Haser model in the inner coma region, while it was consistent with the model in the outer region. The average sulfur production rate was $Q_S=(4.03{\pm}1.03){\times}10^{27}s^{-1}$, which corresponds to ~1% of the water production rate.

  • PDF