• Title/Summary/Keyword: Dual scan

Search Result 101, Processing Time 0.022 seconds

The study of Addressing Speed in AC-PDP (AC-PDP에서의 Addressing 속도에 관한 연구)

  • Kim, Young-Dae;Son, Jae-Bong;Park, Chung-Hoo;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1827-1829
    • /
    • 2000
  • To replace the dual scan system by single scan in large ac plasma display(PDP), the addressing time should be reduced by modifying cell structure and driving circuits. Moreover. the luminance of the PDP can be also increased with the decrease in the addressing time. In this paper, various shapes of bus and address electrode have been investigated to reduce the addressing time in ADS driving method. The experimental results show that the addressing time can be reduced more than 30% compared to the conventional type by modifying the electrodes without reducing the luminance of the PDP.

  • PDF

New Shaped Electrodes to Reduce Addressing Time in a Large AC Plasma Display Panel

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Park, Chung-Hoo;Jang, Yun-Seok;Ryu, Jae-Hwa
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.10-13
    • /
    • 2001
  • The addressing time can be reduced by modifying cell structure and/or driving circuits in order to replace the dual scan system by single scan in large ac plasma display panel(PDP). Moreover, the luminance of the PDP can also be increased by decreasing the addressing time. In this paper, various shapes of bus and address electrodes have been investigated with the aim of reducing the addressing time in ADS driving method. The experimental results show that the addressing time can be reduced by more than 30% compared with the conventional type by modifying the electrodes without reducing the luminance of the PDP.

  • PDF

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

Dual Sensing with Voltage Shifting Scheme for High Sensitivity Touch Screen Detection (고감도 터치스크린 감지를 위한 양방향 센싱과 전압쉬프팅을 이용한 센싱 기법)

  • Seo, Incheol;Kim, HyungWon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.71-79
    • /
    • 2015
  • This paper proposes a new touch screen sensing method that improves the drawback of conventional single-line sensing methods for mutual capacitance touch screen panels (TSPs). It introduces a dual sensing and voltage shifting method, which reduces the ambient noise effectively and enhances the touch signal strength. The dual sensing scheme reduces the detection time by doubling the integration speed using both edges of excitation pulse signals. The voltage shifting method enhances the signal-to-noise ratio (SNR) by increasing the voltage range of integrations, and maximizing the ADC's input dynamic range. Simulation and experimental results using a commercial 23" large touch screen show an SNR performance of 43dB and a scan rate 2 times faster than conventional schemes - key properties suited for a large touch screen panels. We implemented the proposed method into a TSP controller chip using Magnachip's CMOS 0.18um process.

Dual - Drive & - Emission Panel

  • Miyashita, Takuya;Naka, Shigeki;Okada, Hiroyuki;Onnagawa, Hiroyoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.707-710
    • /
    • 2004
  • We have proposed on dual-drive & -emission (DDE) panel based on organic light-emitting diodes (OLEDs). The device is composed on independent operation of two OLED structures with two transparent electrodes for data signals and an intermediate reflective electrode for common scan signal. Typical device structure is ITO / organic electroluminescent layer (1) /intermediate reflective electrode / organic electroluminescent layer (2) /transparent electrode. Symmetric bright emission could be obtained by applying AlNd as the intermediate reflective electrode and $MoO_3$ as a hole injection layer for upper device structure. The proposed panel is useful for emissive face-to-face panel exhibited for different images.

  • PDF

Using a high-resolution LED display Dual Scanning Image Control System Design (듀얼 스캐닝을 이용한 고해상 LED 전광판 영상제어장치설계)

  • Ha, Young-Jea;Kim, In-Jea;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1415-1422
    • /
    • 2011
  • In this paper, full color billboards for the efficient expression of the resolution to offer dual-scanning control method, using the LED display it on a fixed pixel video signal to the pixel dot pattern was changed. And DICT(Dynamic Image Correction Technology) using the main controller in accordance with video information, histogram equalization of image gray scale values to be uniformly distributed, and dynamically improves image quality by converting the area, and a dual auto-scan input video switching controller board as the pixels in the LED Module by controlling the physical manifestation of the existing board LED pixel dots than 4 times the resolution proposes a technique that can be expressed and made it through testing verified the performance.

A Multi-purpose Fingerprint Readout Circuit Embedding Physiological Signal Detection

  • Eom, Won-Jin;Kim, Sung-Woo;Park, Kyeonghwan;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.793-799
    • /
    • 2016
  • A multi-purpose sensor interface that provides dual-mode operation of fingerprint sensing and physiological signal detection is presented. The dual-mode sensing capability is achieved by utilizing inter-pixel shielding patterns as capacitive amplifier's input electrodes. A prototype readout circuit including a fingerprint panel for feasibility verification was fabricated in a $0.18{\mu}m$ CMOS process. A single-channel readout circuit was implemented and multiplexed to scan two-dimensional fingerprint pixels, where adaptive calibration capability against pixel-capacitance variations was also implemented. Feasibility of the proposed multi-purpose interface was experimentally verified keeping low-power consumption less than 1.9 mW under a 3.3 V supply.

Moving Target Position Detecting System using Dual Line CCD and Photometric Interpolation

  • Ryu, Kwang-Ryol;Kim, Young-Bin
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.366-371
    • /
    • 2009
  • A realization for an accurate position detecting system of a moving target in two dimensional plane using dual line CCDs and photometric interpolation is presented. The system is realized that the infrared LEDs are utilized for lighting source, a target size is recognized by the scanned data from CCD owing to blocking the radiated light path by placing the target between CCD and lighting source, a coordinate on the plane is found by plane trigonometry formed by the moving target and two CCD sensors, and the former scan data is used for the coordinate iteratively and the photometric interpolation is applied to sub-pixel of scanned image. The experimental results show that the experiment results in a success rate about 3 different size targets, 3, 5 and 7mmm on the test plane $210{\times}373mm$. The moving target positioning detected success rate is 93% in 3mm target, 5mm is 95.3%, and 7mm is 95.8% respectively. The photometric interpolation is enhanced to 1.5% in comparison to be unused.

Reduction of the Useless Radiation Exposure to Patients and Improvement of the Skill to Manage the Test according to Minimizing Changes of Posture in Bone Mineral Density (골밀도 검사에서 환자 자세 변경 최소화에 따른 수검자의 불필요한 피폭선량 감소 및 생산성 향상)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.228-235
    • /
    • 2009
  • As we recognize the health care, test of BMD is increased. There are various methods in BMD, Dual Energy X-ray absorptiometry (DEXA) which has high precision and accuracy, and low medical exposure dose has been widely used. To measure the changes of BMD, the test must be done as same posture at first and follow up study performed a year. we analyze the difference in the hour taken before and after the examination by radiologic technologist, frequency of scout scan, and the amount of the radiation exposure. The hour of the examination and frequency of the scout scan were shorten and the dose of the radiation exposure is reduced. As the numerical value of total subjects is converted into that of one person, the duration for the test was 52 seconds, the frequency for the scout scan 0.79 time, and the dose for the radiation exposure $13{\mu}Sv$. When the health care provider perform the precise and easy methods to minimize changes of posture and the skillful ability to manage the test, useless radiation is decreased.