• Title/Summary/Keyword: Dual process

Search Result 997, Processing Time 0.032 seconds

A Study on the Cold Formability of Drawn Dual-Phase Steels (신선 가공된 이상 조직강의 냉간 성형성에 대한 연구)

  • 박경수;최상우;이덕락;이종수
    • Transactions of Materials Processing
    • /
    • v.13 no.1
    • /
    • pp.84-89
    • /
    • 2004
  • There is a growing interest to replace the commercial steels with non-heat treated steels, which does not involve the spheroidization and quenching-tempering treatment. However, Non-heat treated steels should satisfy high strength and good formability without performing heat treatment. Therefore, it is important to investigate optimum materials showing a good combination of strength and formability after the drawing process. In this study, Dual-Phase Steels were studied as candidate materials for non-heat treated steels, which have different martensite morphologies and volume fractions obtained through heat-treatment of intercritical quenching (IcQ), intermediate quenching (ImQ) and step quenching (SQ). The mechanical properties of DP steels were measured by tension and compression tests. Also, the cold formability of three DP steels which have similar tensile strength value was investigated by estimating the deformation resistance and the forming limit. The deformation resistance which is important factor in determining die life was estimated by calculating the deformation energy. And the forming limit was estimated by measuring the critical strain revealing crack initiation at the notch tip of the specimens.

A Fast Locking Dual-Loop PLL with Adaptive Bandwidth Scheme (루프 대역폭 조절기를 이용한 빠른 위상 고정 시간을 갖는 이중 루프 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.65-70
    • /
    • 2008
  • A novel fast locking dual-loop integer-N phase locked loop(PLL) with adaptive bandwidth scheme is presented. When the PLL is out-of-lock, bandwidth becomes much wider than 1/10 of channel spacing with the wide bandwidth loop. When the PLL is near in-lock, bandwidth becomes narrower than 1/10 of channel spacing with the narrow bandwidth loop. The proposed PLL is designed based on a $0.35{\mu}m$ CMOS process with a 3.3V supply voltage. Simulation results show the fast look time of $50{\mu}s$ for an 80MHz frequency jump in a 200KHz channel spacing PLL with almost 14 times wider bandwidth than the channel spacing.

A Multi-purpose Fingerprint Readout Circuit Embedding Physiological Signal Detection

  • Eom, Won-Jin;Kim, Sung-Woo;Park, Kyeonghwan;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.793-799
    • /
    • 2016
  • A multi-purpose sensor interface that provides dual-mode operation of fingerprint sensing and physiological signal detection is presented. The dual-mode sensing capability is achieved by utilizing inter-pixel shielding patterns as capacitive amplifier's input electrodes. A prototype readout circuit including a fingerprint panel for feasibility verification was fabricated in a $0.18{\mu}m$ CMOS process. A single-channel readout circuit was implemented and multiplexed to scan two-dimensional fingerprint pixels, where adaptive calibration capability against pixel-capacitance variations was also implemented. Feasibility of the proposed multi-purpose interface was experimentally verified keeping low-power consumption less than 1.9 mW under a 3.3 V supply.

Noise Analysis of Common Source CMOS Pair for Dual-Band LNA (이중밴드 저잡음 증폭기 설계를 위한 공통 소스 접지형 CMOS쌍의 잡음해석)

  • Cho, Min-Soo;Kim, Tae-Sung;Kim, Byung-Sung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.168-172
    • /
    • 2003
  • This paper analyzes the output noise and the noise figure of common source MOSFET pair each input of which is separately driven in the different frequencies. This analysis is performed for concurrent dual band cascode CMOS LNA with double inputs and single output fabricated in $0.18{\mu}m$ CMOS process. Since both inputs and output are matched to near $50{\Omega}$ using on-chip inductors, the measured noise figures are much higher than those of usual CMOS LNA. But, the main concern of this paper is focused on the added noise features due to the other channel common source stage. The dual-band LNA results in noise figure of 4.54dB at 2.14GHz and 6.03dB at 5.25GHz for selectable operation and 7.44dB and 6.58dB for concurrent operation. The noise analysis explains why the added noise at each band shows so large difference.

  • PDF

A Visualization of the Spray from Small Liquid-rocket Engine Injector by Dual-mode Phase Doppler Anemometry (이중모드 위상도플러 속도계측기법에 의한 소형 액체로켓엔진 인젝터 분무의 가시화)

  • Jung, Hun;Kim, Jeong-Soo;Bae, Dae-Seok;Kwon, Oh-Boong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.60-65
    • /
    • 2010
  • A focus is given to the breakup behavior of spray droplets issuing from a nonimpinging-type injector. The analysis has been carried out experimentally by means of the dual-mode phase Doppler anemometry (DPDA). Spray characteristic parameters in terms of axial velocity, mean diameter, velocity fluctuation, and span (width of the size distribution) of droplets are measured down the geometric axis of a nozzle orifice and on the plane normal to the spray stream with the injection pressure variations. As the injection pressure increases, the velocity and its fluctuation become higher, whereas the droplet sizes get smaller. It is also shown that the magnitudes of those parameters are smoothed out by dispersion when the droplets move downstream as well as outwardly. The atomization process is significantly influenced by the injection pressure rather than the traveling distance in the experimental condition presented.

A Study on Shape Measurement by Using Electronic Speckle Pattern Interferometry (전자 스페클 패턴 간섭법을 이용한 형상 측정에 관한 연구)

  • 강영준;김계성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.156-164
    • /
    • 1998
  • Electronic Speckle Pattern Interferometry(ESPI) has been used to measure surface deformations of engineering components and materials in industrial areas. ESPI, a non-contact and non-destructive technique, is capable of providing full-field results with high spatial resolution and high speed. One of the important application using electronic speckle pattern interferometry is electronic speckle contouring of a diffused object for 3-D shape analysis and topography measurement. Generally the electronic speckle contouring is suitable for providing measurement range from millimeters to several centimeters. In this study, we introduce the contouring method by modified dual-beam speckle pattern interferometer and the shift of the two illumination beams through optical fiber in order to obtain the contour fringe patterns. We also describe formation process of depth contour fringes and grid contour fringes by shifting direction of the two illumination beams. Before the experiments, we performed the geometric analysis for dual-beam-shifted ESPI contouring, and then, the electronic speckle contouring experiment with various specimens. For quantitative analysis of the contour fringes, we used 4-frame phase shifting method with PZT Finally, good agreement between the geometric analysis and experimetal results is obtained.

  • PDF

Biphasic Activity of Chloroquine in Human Colorectal Cancer Cells

  • Park, Deokbae;Lee, Youngki
    • Development and Reproduction
    • /
    • v.18 no.4
    • /
    • pp.225-231
    • /
    • 2014
  • Autophagy is a homeostatic degradation process that is involved in tumor development and normal development. Autophagy is induced in cancer cells in response to chemotherapeutic agents, and inhibition of autophagy results in enhanced cancer cell death or survival. Chloroquine (CQ), an anti-malarial drug, is a lysosomotropic agent and is currently used as a potential anticancer agent as well as an autophagy inhibitor. Here, we evaluate the characteristics of these dual activities of CQ using human colorectal cancer cell line HCT15. The results show that CQ inhibited cell viability in dose- and time-dependent manner in the range between 20 to 80 uM, while CQ did not show any antiproliferative activity at 5 and 10 uM. Cotreatment of CQ with antitumor agent NVP-BEZ235, a dual inhibitor of PI3K/mTOR, rescued the cell viability at low concentrations meaning that CQ acted as an autophagy inhibitor, but CQ induced the lethal effect at high concentrations. Acridine orange staining revealed that CQ at high doses induced lysosomal membrane permeabilization (LMP). High doses of CQ produced cellular reactive oxygen species (ROS) and cotreatment of antioxidants, such as NAC and trolox, with high doses of CQ rescued the cell viability. These results suggest that CQ may exert its dual activities, as autophagy inhibitor or LMP inducer, in concentration-dependent manner.

Effect of Diesel Injection Characteristics on Biogas-Diesel Dual Fuel Engine Performance (디젤 분사 특성이 Biogas-디젤 혼소엔진 성능에 미치는 영향)

  • Lee, Sun-Youp;Kim, Young-Min;Lee, Jang-Hee
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.195-201
    • /
    • 2010
  • Due to its carbon-neutral nature, biogas generated from anaerobic digestion or fermentation of biodegradable wastes is one of the important renewable energy sources to reduce global warming. It is mainly composed of methane and various inert gases such as $CO_2$ and $N_2$, and the actual composition of biogas significantly varies depending on the origin of anaerobic digestion process. Therefore, in order to effectively utilize this fuel as an energy source for electricity, it is important to develop power generation engines which can successfully apply biogas with significant composition variations. In this study, efforts have been made to develop a diesel-biogas duel fuel engine as a way to achieve such a stable power generation. The effects of diesel fuel injection quantity and pressure on stable combustion and engine performance were investigated, and an impact of diesel fuel atomization was discussed. The engine test results show that there exists a 2 stage combustion which consists of diesel pilot fuel burning and premixed biogas/air mixture burning in dual fuel engine operation and optimum diesel injection parameters were suggested for biogases with various compositions and heating values.

Performance Simulation of BOG Reliquefaction System for Dual Fuel Engine of LNG Carrier (LNG 선박 Dual Fuel 엔진용 BOG 재액화 시스템의 성능 시뮬레이션)

  • Lee, Sang-Hoon;Shin, You-Hwan;Lee, Yoon-Pyo;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.148-153
    • /
    • 2008
  • As the oil price is dramatically jumping up, the consumption of LNG is rapidly expanding and the size of LNG carriers becomes bigger. For LNG ships, the application of DF (Dual-Fuel) engines gradually increases because of high efficiency, which alternatively use diesel or BOG (Boil-Off Gas) from cargo tank as a fuel. The surplus BOG from LNG cargo tank should be exhausted by GCU or liquefied through the BOG reliquefaction system and returned back. This study focused into its operational characteristics through the process simulation using HYSYS and discussed details on the influence of the variations of some operational parameters such as a distribution ratio by the change of fuel mass flow into the DF engine.

  • PDF

Pediatric dual-energy X-ray absorptiometry: interpretation and clinical and research application

  • Lim, Jung Sub
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.286-293
    • /
    • 2010
  • Peak bone mass is established predominately during childhood and adolescence. It is an important determinant of future resistance to osteoporosis and fractures to gain bone mass during growth. The issue of low bone density in children and adolescents has recently attracted much attention and the use of pediatric dual-energy X-ray absorptiometry (DXA) is increasing. The process of interpretation of pediatric DXA results is different from that of adults because normal bone mineral density (BMD) of children varies by age, body size, pubertal stage, skeletal maturation, sex, and ethnicity. Thus, an appropriate normal BMD Z-score reference value with Z-score should be used to detect and manage low BMD. Z-scores below -2.0 are generally considered a low BMD to pediatrician even though diagnoses of osteoporosis in children and adolescents are usually only made in the presence of at least one fragility fracture. This article will review the basic knowledge and practical guidelines on pediatric DXA based on the International Society for Clinical Densitometry (ISCD) Pediatric Official Positions. Also discussed are the characteristics of normal Korean children and adolescents with respect to BMD development. The objective of this review is to help pediatricians to understand when DXA will be useful and how to interpret pediatric DXA reports in the clinical practice for management of children with the potential to develop osteoporosis in adulthood.