• 제목/요약/키워드: Dual layer phoswich detector

검색결과 4건 처리시간 0.024초

Development of Analytical Model for Optimization of Dual Layer Phoswich Detector Length for PET

  • Chung Yong Hyun;Choi Yong;Choe Yearn Seong;Lee Kyung-Han;Kim Byung-Tae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.17-22
    • /
    • 2005
  • Small animal PET using a dual layer phoswich detector has been developed to obtain high and uniform spatial resolution. In this study, a simple analytic model to optimize the lengths of a dual layer phoswich detector was derived and validated by Monte Carlo simulation. For a small animal PET scanner with a 10㎝ ring diameter, the optimal length of the phoswich detector consisting of various crystal materials, such as LSO and LuYAP, were calculated analytically and validated using GATE. The detector module consisted of 8×8 arrays of crystals, with each phoswich detector element having a 2㎜×2㎜ sensitive area. The total crystal length was fixed to 20㎜. The optimal lengths of the phoswich detector layers, as functions of the crystal materials and order, conveniently derived by the analytic equation, showed good agreement with those estimated by the time consuming simulation. The simple analytical model can be used for the fast and accurate design of an optimal phoswich detector for small animal PET to achieve high spatial resolution and uniformity.

Optimization of Dual Layer Phoswich Detector for Small Animal PET using Monte Carlo Simulation

  • Y.H. Chung;Park, Y.;G. Cho;Y.S. Choe;Lee, K.H.;Kim, S.E.;Kim, B.T.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.44-44
    • /
    • 2003
  • As a basic measurement tool in the areas of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly. An ideal small animal PET should have high sensitivity and high and uniform resolution across the field of view to achieve high image quality. However, the combination of long narrow pixellated crystal array and small ring diameter of small animal PET leads to the degradation of spatial resolution for the source located at off center. This degradation of resolution can be improved by determining the depth of interaction (DOI) in the crystal and by taking into account the information in sorting the coincident events. Among a number of 001 identification schemes, dual layer phsowich detector has been widely investigated by many research groups due to its practicability and effectiveness on extracting DOI information. However, the effects of each crystal length composing dual layer phoswich detector on DOI measurements and image qualities were not fully characterized. In order to minimize the DOI effect, the length of each layer of phoswich detector should be optimized. The aim of this study was to perform simulations using a simulation tool, GATE to design the optimum lengths of crystals composing a dual layer phoswich detector. The simulated small PET system employed LSO front layer LuYAP back layer phoswich detector modules and the module consisted of 8${\times}$8 arrays of dual layer crystals with 2 mm ${\times}$ 2 mm sensitive area coupled to a Hamamatsu R7600 00 M64 PSPMT. Sensitivities and variation of radial resolutions were simulated by varying the length of LSO front layer from 0 to 10 mm while the total length (LSO + LuYAP) was fixed to 20 mm for 10 cm diameter ring scanner. The radial resolution uniformity was markedly improved by using DOI information. There existed the optimal lengths of crystal layers to minimize the variation of radial resolutions. In 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm over 8 cm FOV while the sensitivity was higher than 7.4% for LSO 5 mm : LuYAP 15 mm phoswich detector. In this study, the optimal length of dual layer phoswich detector was derived to achieve high and uniform radial resolution.

  • PDF

두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과 (Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results)

  • 정명환;최용;정용현;송태용;정진호;홍기조;민병준;최연성;이경한;김병태
    • 대한핵의학회지
    • /
    • 제38권5호
    • /
    • pp.338-343
    • /
    • 2004
  • 목적: 이 연구의 목적은 두층 섬광결정을 사용하여 PET 기기 시야 외곽에서 발생하는 영상 왜곡현상을 최소화하는 고 민감도, 고 분해능의 소동물 PET 시스템을 개발하는 것이다. 대상 및 방법: GATE (Geant4 Application for Tomographic Emission) 시뮬레이션 프로그램을 사용하여 시스템을 모사하였고 시스템 성능을 예측하였으며 시뮬레이션에서 도출한 파라미터를 기준으로 시스템을 설계 제작 하였다. 두층 섬광결정은 Lutetium Oxyorthosilicate (LSO)와 Lutetium-Yttrium Aluminate-Perovskite (LuYAP)으로 구성하였다. 섬광결정의 각 픽셀크기는 $2mm{\times}2mm{\times}8mm$이며 $8{\times}8$로 배열하여 두층 섬광결정으로 구성하였다. 두층 섬광결정 배열을 위치민감형 광전자증배관(Position Sensitive Photomultiplier Tube: PSPMT)과 결합하여 한 개의 검출기를 구성하였으며, 총 16개 검출기를 지름 10 cm, 유효시야 8 cm인 원형으로 배열하였다. 검출기로부터 출력된 데이터는 소켓, 디코더, ADC, FPGA회로를 거쳐 전 처리 컴퓨터에 입력되고 마스터 컴퓨터에 저장 되도록 하였다. 결과: 시스템 개발의 초기 연구로 한쌍 검출기만 사용하여 단층영상을 획득하고 민감도와 공간분해능을 측정하였다. 점선원을 시야 중앙에 위치했을 때 공간분해능은 2.3 mm FWHM이고, 민감도는 10.9 $cps/{\mu}Ci$이었다. 결론: 구축한 시스템을 사용하여 선원의 위치와 모양변화를 정확하게 측정한 사이노그램과 PET 영상을 획득할 수 있었다. 이 연구는 고 분해능 고 민감도 PET 시스템 개발의 초기연구로, 소형 원형 PET 시스템 개발 가능성을 보여준다.lamate을 이용하여 측정한 사구체 여과율과 통계적으로 유의한 상관 관계를 보이지 않았다. 결론: Gates 방법을 이용한 사구체 여과율 측정에서 배후 방사능 관심 영역은 신장의 상방과 양측 신장사이, 즉 혈액 풀 방사능이 많이 분포하는 부위에 설정하는 것이 I-125-iothalamate을 이용한 사구체 여과율과 가장 높은 상관 관계를 보였고, 신장 깊이가 깊지 않은 2군에서 두 사구체 여과율은 더 높은 상관 관계를 보였다.7%$, 25분일 때 $95{\pm}12%$, 40분일 때 $98{\pm}3%$로 통계학적으로 유의한 차이는 없었다(p>0.05). 항응고제 종류에 따른 결합효율은 헤파린을 사용한 경우 $89{\pm}20%$, CPDA를 사용한 경우 $97{\pm}6%$, ACD를 사용한 경우 $98{\pm}4%$로 CPDA와ACD를 사용한 경우에 유의하게 높은 결합효율을 보였다(p<0.001). 결론: 변형 체내 표지법으로 적혈구를 표지시 우수한 결합효율을 유지하기 위해서는 채취하는 혈액의 양은 3 mL 이상, 배양시간은 10분 이상(10분-40분), 항응고제는 ACD나 CPDA tinning 시간은 20분 이상(20-35분)을 유지하고, 가능한 rotating invertor를 사용하는 것이 좋을 것으로 생각된다.KC $\varepsilon$이 K562(Adr)세포에서 많이 발현되었으나, K562와 K562(Adr)세포에서는 verapamil처리에 따른 PKC 아형의 변화는 없었다. 결론: Verapamil은 암세포의 종류에 따라 MIBI와 TF의 섭취를 감소시켰고, 고용량에는 MDR세포의 섭취도 감소시켰으며 이러한 현상은 세포독성 이나 PKC효소 아형과는 관련이 없었다. 그러므로 MDR의 진단시 verapamil을

알파 및 베타선 동시측정용 ZnS(Ag)/플라스틱 이중섬광체 검출센서 개발 (Development of ZnS(Ag)/plastic dual scintillator sheet for simultaneous alpha- and beta-ray counting)

  • 서범경;우주희;김계홍;이근우;이동규;정종현
    • 분석과학
    • /
    • 제21권2호
    • /
    • pp.117-122
    • /
    • 2008
  • 표면오염도 측정용 검출소재로 주로 이용되고 있는 알파와 베타선의 동시 측정용 이중섬광체 검출소재를 개발하였다. 본 연구에서는 기존의 열용융 공정이 아닌, 고분자 소재를 용매로 녹여서 검출소재를 제조하는 용매법을 이용함으로써 제조공정을 단순화하였다. 베타선 측정용 플라스틱 섬광체는 유기섬광체, 고분자, 그리고 용매가 혼합된 용액을 도말한 후에 고형화하여 제조하였다. ZnS(Ag) 섬광체는 플라스틱 섬광체 위에 ZnS(Ag), 접착소재, 그리고 용매가 혼합된 용액을 스크린 프린팅 방법으로 도포하여 제조하였다. 제조한 이중섬광체의 알파선과 베타선에 대한 방사능 검출 성능을 평가한 결과 우수한 검출 성능을 확인하였으며, 표염오염도 측정용 소재로 적용이 가능함을 확인하였다.