• Title/Summary/Keyword: Dual imaging

Search Result 215, Processing Time 0.022 seconds

Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test (PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석)

  • Kim, Myungsoo;Kim, Giyoon;Lee, Minju;Kang, Dong-uk;Lee, Daehee;Park, Kyeongjin;Kim, Yewon;Kim, Chankyu;Kim, Hyoungtaek;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

Design and Fabrication of Dual Tip Si3N4 Probe for Dip-pen Nanolithograpy (Dip-pen nanolithography를 위한 이중 팁을 가진 질화규소 프로브의 설계 및 제조)

  • Kim, Kyung Ho;Han, Yoonsoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.6
    • /
    • pp.362-367
    • /
    • 2014
  • We report the design, fabrication of a $Si_3N_4$ probe and calculation of its mechanical properties for DPN(dip pen nanolithography), which consists of dual tips. Concept of dual tip probe is to employ individual tips on probe as either an AFM tip for imaging or a writing tip for nano patterning. For this, the dual tip probe is fabricated using low residual stress $Si_3N_4$ material with LPCVD deposition and MEMS fabrication process. On the basis of FEM analysis we show that the functionality of dual tip probe for imaging is dependent on the dimensions of dual tip probe, and high ratio of widths of beam areas is preferred to minimize curvature variation on probe.

Spectral Computed Tomography: Fundamental Principles and Recent Developments

  • Aaron So;Savvas Nicolaou
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.86-96
    • /
    • 2021
  • CT is a diagnostic tool with many clinical applications. The CT voxel intensity is related to the magnitude of X-ray attenuation, which is not unique to a given material. Substances with different chemical compositions can be represented by similar voxel intensities, making the classification of different tissue types challenging. Compared to the conventional single-energy CT, spectral CT is an emerging technology offering superior material differentiation, which is achieved using the energy dependence of X-ray attenuation in any material. A specific form of spectral CT is dual-energy imaging, in which an additional X-ray attenuation measurement is obtained at a second X-ray energy. Dual-energy CT has been implemented in clinical settings with great success. This paper reviews the theoretical basis and practical implementation of spectral/dual-energy CT.

Polymeric nanoparticles as dual-imaging probes for cancer management

  • Menon, Jyothi U.;Jadeja, Parth;Tambe, Pranjali;Thakore, Dheeraj;Zhang, Shanrong;Takahashi, Masaya;Xie, Zhiwei;Yang, Jian;Nguyen, Kytai T.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.3
    • /
    • pp.129-140
    • /
    • 2016
  • This article reports the development of biodegradable photoluminescent polymer (BPLP)-based nanoparticles (NPs) incorporating either magnetic nanoparticles (BPLP-MNPs) or gadopentate dimeglumine (BPLP-Gd NPs), for cancer diagnosis and treatment. The aim of the study is to compare these nanoparticles in terms of their surface properties, fluorescence intensities, MR imaging capabilities, and in vitro characteristics to choose the most promising dual-imaging nanoprobe. Results indicate that BPLP-MNPs and BPLP-Gd NPs had a size of $195{\pm}43nm$ and $161{\pm}55nm$, respectively and showed good stability in DI water and 10% serum for 5 days. BPLP-Gd NPs showed similar fluorescence as the original BPLP materials under UV light, whereas BPLP-MNPs showed comparatively less fluorescence. VSM and MRI confirmed that the NPs retained their magnetic properties following encapsulation within BPLP. Further, in vitro studies using HPV-7 immortalized prostate epithelial cells and human dermal fibroblasts (HDFs) showed > 70% cell viability up to $100{\mu}g/ml$ NP concentration. Dose-dependent uptake of both types of NPs by PC3 and LNCaP prostate cancer cells was also observed. Thus, our results indicate that BPLP-Gd NPs would be more appropriate for use as a dual-imaging probe as the contrast agent does not mask the fluorescence of the polymer. Future studies would involve in vivo imaging following administration of BPLP-Gd NPs for biomedical applications including cancer detection.

Design of an Infrared Camera using a Dual-band Infrared Detector (이중대역 적외선 검출기를 이용한 적외선 카메라 설계)

  • Park, Jin-Ho;Kim, Hong-Rak;Kim, Kyoung-Il;Lee, Da-Been
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.93-97
    • /
    • 2022
  • Infrared scenes usually contain also spectral information which cannot be resolved using normal single-band infrared cameras. Multispectral infrared imaging cameras give access to the comprehensive information contained within infrared scenes. A Dual-band infrared Camera, a type of multispectral infrared imaging cameras, has the advantage of simple system. A Dual-band Infrared Camera gives access to the spectral information as wells as the temperature information within infrared scenes. Multispectral imaging generally increases the detection and identification performance of a Dual-band Infrared Camera. This paper describes a design of an infrared Camera using a Dual-band Infrared Detector to simultaneously receive infrared radiation from the medium-wave infrared/long-wave infrared(MWIR/LWIR) bands.

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

An Optimum Selection of Dual Coding Subfield Pattern for Plasma Displays

  • Kwak, Dong-Chan;Kim, Choon-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.730-733
    • /
    • 2003
  • Dual coding technique is one of the popular techniques to reduce the dynamic false contours on PDP. Subfield pattern is a key factor affecting the performance of dual coding technique. In this paper, an optimum subfield selection method based on genetic algorithm is proposed. Two types of string structures are defined to account for all the possible configurations of the dual coding subfield patterns. Genetic operators are proposed for optimization of dual coding subfield pattern. Quantitative measures to describe degrees of dynamic false contours and checkerboard patterns are defined. Experimental results indicate that dual coding subfield pattern that is determined by proposed method reduces dynamic false contours and checkerboard patterns.

  • PDF

Development of Infrared Target for Dual-Sensor Imaging Seeker's Test and Evaluation in HILS System (이종센서 영상탐색기 시험평가를 위한 적외선 표적원 개발)

  • Park, Changhan;Song, Sungchan;Jung, Sangwoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.898-905
    • /
    • 2018
  • In this work, infrared targets for a developed hardware-in-the-loop simulation(HILS) system are proposed for a performance test of a dual-sensor imaging seeker equipped with an infrared and a visible sensor that can lock and track for ground and air targets. This integrated system is composed of 100 modules of heat and light sources to simulate various kinds of target and the trajectory of moving targets based on scenarios. It is possible to simulate not only the position, velocity, and direction for these targets but also background clutter and jamming environments. The design and measurement results of an infrared target, such as the HILS system configuration, developed for testing and evaluation of a dual-sensor imaging seeker are described. In the future, it is planned to test the lock-on and tracking performance of an imaging seeker equipped with single or dual sensors dynamically in real time based on a simulation flight scenario in the developed HILS system.

Recent Progress in MRI Contrast Agent with Ceramic LDH Nanohybrids (세라믹 LDH 나노하이브리드를 이용한 MRI 조영제의 최신 연구동향)

  • Ha, Seongjin;Jin, Wenji;Park, Dae-Hwan
    • Ceramist
    • /
    • v.22 no.3
    • /
    • pp.269-280
    • /
    • 2019
  • Ceramic layered double hydroxide (LDH) nanohybrids have attracted considerable interest in biomedical science due to their unique structural feature and characteristics in biological condition. Many studies on LDH nanoparticles have been reported in diagnosis applications including magnetic resonance imaging (MRI) contrast agents in order to not only provide better imaging performance through multimodal imaging strategy, but realize therapeutic function which treat cancers in one platform. This review highlights the recent progress in MRI T1 contrast agent, dual modal imaging system, and MRI-guided drug delivery systems ranging from synthetic method and characterization to evaluation in vitro and in vivo based on the ceramic LDH nanohybrids. Future research directions are also suggested for next-generation bio-imaging contrast agent.

Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection (인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구)

  • Kim, Seung Ho;Kim, Dong Woon;Kim, Daecheon;Kim, Junwoo;Park, Ji Woong;Park, Eunpyeong;Kim, Jinwoo;Kim, Ho Kyung
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.