• Title/Summary/Keyword: Dual Loop

Search Result 234, Processing Time 0.025 seconds

Improvement of Phase Noise in Frequency Synthesizer with Dual PLL (이중 PLL 구조 주파수 합성기의 위상 잡음 개선)

  • Kim, Jung-Hoon;Park, Beom-Jun;Kim, Jee-Heung;Lee, Kyu-Song
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.903-911
    • /
    • 2014
  • This paper proposes a high speed frequency synthesizer with dual phase-locked loop(PLL) structure to improve phase noise level and shape in a wideband receiver. To reduce phase noise and fractional spur, a output frequency of $1^{st}$ PLL used as reference frequency of $2^{nd}$ PLL is changed. The frequency synthesizer has been designed with 1 Hz frequency resolution using digital NCO in 6.5~8.5 GHz wide spectrum. The measured results of the fabricated frequency synthesizer show that the output power is about -3 dBm, the maximum lock-in time and phase noise are within 60 us and -95 dBc/Hz at 10 kHz offset, respectively.

Adaptive Feedforward Rejection of Microactuator Resonance in Hard Disk Drive Dual-stage Actuator Servo (하드디스크 드라이브 마이크로 구동기의 공진 영향 제거를 위한 적응 피드포워드 제어)

  • Oh, Dong-Ho;Lee, Seung-Hi;Baek, Sang-Eun;Na, Hee-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1596-1600
    • /
    • 2000
  • We propose a novel adaptive feed forward controller (AFC) design method for rejecting the effect of micro actuator resonance in the design of dual-stage actuator servo systems for disk drives. Microactuator's resonance is one of important issues in dual-stage actuator servo, which varies up to ${\pm}10%$ per product and even during operation. We derive an adaptive algorithm for the proposed AFC design, which turns out to be identical to the delayed-x LMS algorithm which is a special form of the filtered-x LMS algorithm. In the algorithm, coefficients of the AFC are adapted by the residuals of constrained structure defined in such a way that the coefficients become time invariant. Contrary to the conventional AFC, it considers the phase delay of closed-loop transfer function at resonance frequency for system stability. We also apply an adaptive algorithm with frequency tracking capability. The frequency tracking algorithm is induced by the orthogonality of AFC coefficients. Computer simulations are carried out to demonstrate effect of the proposed AFCs.

  • PDF

A Dual Buck Three-Level PV Grid-Connected Inverter

  • Ji, Baojian;Hong, Feng;Wang, Jianhua;Huang, Shengming
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.910-919
    • /
    • 2015
  • The use of a PV grid-connected inverter with non-isolated topology and without a transformer is good for improving conversion efficiency; however, this inverter has become increasingly complicated for eliminating leakage current. To simplify the complicated architecture of traditional three-level dual buck inverters, a new dual Buck three-level PV grid-connected inverter topology is proposed. In the proposed topology, the voltage on the grounding stray capacitor is clamped by large input capacitors and is equal to half of the bus voltage; thus, leakage current can be eliminated. Unlike in the traditional topology, the current in the proposed topology passes through few elements and does not flow through the body diodes of MOSFET switches, resulting in increased efficiency. Additionally, a multi-loop control method that includes voltage-balancing control is proposed and analyzed. Both simulation and experimental results are demonstrated to verify the proposed structure and control method.

Dual-Mode Reference-less Clock Data Recovery Algorithm (이중 모드의 기준 클록을 사용하지 않는 클록 데이터 복원 회로 알고리즘)

  • Kwon, Ki-Won;Jin, Ja-Hoon;Chun, Jung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.77-86
    • /
    • 2016
  • This paper describes a dual-mode reference-less CDR(Clock Data Recovery) operating at full / half-rate and its operation algorithm. Proposed reference-less CDR consists of a frequency detector, a phase detector, a charge pump, a loop filter, a voltage controlled oscillator, and a digital block. The frequency and phase detectors operate at both full / half-rate for dual-mode operation and especially the frequency detector is capable of detecting the difference between data rate and clock frequency in the dead zone of general frequency detectors. Dual-mode reference-less CDR with the proposed algorithm can recover the data and clock within 1.2-1.3 us and operates reliably at both full-rate (2.7 Gb/s) and half-rate (5.4 Gb/s) with 0.5-UI input jitter.

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

Development of the Control Algorithm for the Small PEM Fuel Cell Stack (소형 PEM 연료전지 스택의 제어 알고리즘 개발)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.134-141
    • /
    • 2010
  • Small PEM (Proton Exchange Membrane) fuel cell systems do not require humidification and have great commercialization possibilities. However, methods for controlling small PEM fuel cell stacks have not been clearly established. In this paper, a control method for small PEM fuel cell systems using a dual closed loop with a static feedforward structure is defined and realized using a DSP (Digital Signal Processor). The fundamental elements that need to be controlled in fuel cell systems include the supply of air and hydrogen, water management inside the stack, and heat management of the stack. For small PEM fuel cell stacks operated without a separate humidifier, fans are essential for air supply, heat management, and water management of the stack. A purge valve discharges surplus water from the stack. The proposed method controls the fan using double control loops to quicken transient response of the fan thereby improving the supply rate of air. Feedback control to compensate for the voltage change in fuel cell stack improves the response characteristics in fuel cell to load variations. The feasibility of proposed method was proved by the experiments with a 60W small PEM fuel cell system and operation of a notebook computer using this system.

A Microstrip Dual-Band Band-Pass Filter Using Feed Lines and Resonators with SIR Structures (SIR 구조의 피드 라인과 공진기를 이용한 마이크로스트립 이중대역 대역통과 여파기)

  • Lim, Ji-Eun;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.463-470
    • /
    • 2015
  • In this paper, a new dual-band bandpass filter(BPF) that has resonators and feed lines with Stepped-Impedance Resonator(SIR) structures is proposed. Feed lines with SIR structure provide maximum magnetic field points which occur at the same locations of the input and output feed lines, so the insertion loss of BPF was reduced. Applying the SIR structure to the BPF for the first passband improves rejection characteristics between the first passband and the second passband. It reduces the coupling between the BPF for the first passband and the BPF for the second passband, so it makes the dual-band BPF more compact. The proposed design method provides independent changes of both the center frequency and the bandwidth for each resonator, and also improves filtering characteristics. The validity of the proposed design method is confirmed by comparisons between the designed parameters and the measured results satisfying WLAN specifications.

Research on the Development of the Supercritical CO2 Dual Brayton Cycle (초임계 이산화탄소 이중 브레이튼 사이클 개발 연구)

  • Baik, Young-Jin;Na, Sun Ik;Cho, Junhyun;Shin, Hyung-Ki;Lee, Gilbong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.673-679
    • /
    • 2016
  • Because of the growing interest in supercritical carbon dioxide power cycle technology owing to its potential enhancement in compactness and efficiency, supercritical carbon dioxide cycles have been studied in the fields of nuclear power, concentrated solar power (CSP), and fossil fuel power generation. This study introduces the current status of the research project on the supercritical carbon dioxide power cycle by Korea Institute of Energy Research (KIER). During the first phase of the project, the un-recuperated supercritical Brayton cycle test loop was built and tested. In phase two, researchers are designing and building a supercritical carbon dioxide dual Brayton cycle, which utilizes two turbines and two recuperators. Under the simulation condition considered in this study, it was confirmed that the design parameter has an optimal value for maximizing the net power in the supercritical carbon dioxide dual cycle.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF