• Title/Summary/Keyword: Dual Laser

Search Result 170, Processing Time 0.03 seconds

Spreader Pose Control Using Dual-electric Compasses (Dual compasses를 이용한 스프레더의 자세 제어)

  • Han, Sun-Sin;Jeong, Hee-Seok;Lee, Jang-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.366-368
    • /
    • 2007
  • A spreader pose control system using dual-electric compasses has been implemented by measuring the skew angle of the spreader with dual-electric compasses. In the conventional spreader pose measurement, CCD cameras, laser sensors or tilt sensors are mostly used. However those sensors are not only sensitive to the weather and disturbances but also expensive to build the system. To overcome the shortcomings, an inexpensive and efficient system to control the spreader pose has been implemented using the dual-magnetic compasses. Since the spreader iron-structures are noise sources to the magnetic compass, it is not considered to use the magnetic compass to measure the orientation of the spreader. An algorithm to eliminate the interferences of metal structures to the dual compasses has been developed in this paper. The 10:1 reduction model of a spreader control system is implemented and the control performance is demonstrated to show the effectiveness of the dual-magnetic compasses proposed in this research.

  • PDF

Non-Contacted Strain Analysis by Dual-beam Shearography (변형 해석을 위한 Dual-beam Shearography)

  • 김경석;정성욱;장호섭;최태호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.400-403
    • /
    • 2002
  • This paper presents a shearographic technique for measuring in-plane strains. During the measurement, the test object is illuminated alternately with two laser beams, symmetrically with respect to the viewing direction. Employing a phase shift technique, the phase distributions due to object deformation for each beam are obtained separately. The difference of the two phase distributions depicts the derivative of in-plane surface displacements. The technique is equivalent to a system of many strain gages.

  • PDF

Sequential Delivery of Neodymium:Yttrium-Aluminum-Garnet and Alexandrite Laser Pulses for Treating Light Brown Seborrheic Keratoses

  • Cho, Sung Bin;Oh, Doojin;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.24-27
    • /
    • 2019
  • Seborrheic keratoses (SKs) have been treated with non-ablative longpulsed (LP) lasers, including LP 532-nm neodymium (Nd): yttrium aluminum garnet (YAG), LP 695-nm ruby, LP 755-nm alexandrite (Alex), and LP 1,064-nm Nd:YAG lasers, with a pulse durations of 1-300 msec. Dual-wavelength LP 755-nm Alex/1,064-nm Nd:YAG laser systems have been used to remove hair follicles and treat various vascular and pigmented disorders by sequentially delivering two pulses of different wavelengths with interpulse intervals in the millisecond range. This paper reports the case of a female patient with multiple, discrete, light brown SKs on the dorsum of both hands that were treated effectively with one session of dual-wavelength LP 1,064-nm Nd:YAG/755-nm Alex laser treatment. The treatment settings for the LP Nd:YAG laser were comprised of a wavelength of 1,064 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. The settings for the LP Alex laser were comprised of a wavelength of 755 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. A hybrid mode was used to automatically deliver LP Nd:YAG and LP Alex laser pulses in succession at interpulse intervals of 20 msec. Six weeks after treatment, the patient exhibited remarkable improvement of the light brown seborrheic keratoses and was satisfied with the results.

SOA-Integrated Dual-Mode Laser and PIN-Photodiode for Compact CW Terahertz System

  • Lee, Eui Su;Kim, Namje;Han, Sang-Pil;Lee, Donghun;Lee, Won-Hui;Moon, Kiwon;Lee, Il-Min;Shin, Jun-Hwan;Park, Kyung Hyun
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.665-674
    • /
    • 2016
  • We designed and fabricated a semiconductor optical amplifier-integrated dual-mode laser (SOA-DML) as a compact and widely tunable continuous-wave terahertz (CW THz) beat source, and a pin-photodiode (pin-PD) integrated with a log-periodic planar antenna as a CW THz emitter. The SOA-DML chip consists of two distributed feedback lasers, a phase section for a tunable beat source, an amplifier, and a tapered spot-size converter for high output power and fiber-coupling efficiency. The SOA-DML module exhibits an output power of more than 15 dBm and clear four-wave mixing throughout the entire tuning range. Using integrated micro-heaters, we were able to tune the optical beat frequency from 380 GHz to 1,120 GHz. In addition, the effect of benzocyclobutene polymer in the antenna design of a pin-PD was considered. Furthermore, a dual active photodiode (PD) for high output power was designed, resulting in a 1.7-fold increase in efficiency compared with a single active PD at 220 GHz. Finally, herein we successfully show the feasibility of the CW THz system by demonstrating THz frequency-domain spectroscopy of an ${\alpha}$-lactose pellet using the modularized SOA-DML and a PD emitter.

The Pattern Analysis of Dual & Switch Pulse Signal in Multiple Pulse Train Using the Second Deviation of TOA (TOA 2차 차분을 이용한 다중 펄스열의 Dual & Switch 펄스신호 패턴 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.804-807
    • /
    • 2012
  • 본 논문에서는 펄스 레이저(LASER) 송신기에서 방사되는 펄스신호를 레이저 감시 시스템에서 실시간으로 수신하여 수신된 레이저 펄스들의 변화 패턴, 특히 Dual & Switch 신호의 패턴을 분석하는 방법에 대하여 기술하였다. Dual & Switch 신호는 펄스반복시간이 주기적으로 변경되어 펄스 패턴을 예측하기가 매우 어렵다. 본 논문에서는 펄스반복간격(PRI)의 차분을 이용하여 고정, 지터, Dual & Switch 신호의 패턴을 확인하는 방법을 제안하였다. 제안된 방법은 Dual & Switch 신호에 대한 신호 식별능력이 가능하여 레이저 감시시스템 등에 사용할 수 있을 것으로 판단된다.

  • PDF

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Development of Surgical Two-wavelegth Nd:YAG Laser (수술용 2파장 펄스형 Nd:YAG 레이저 개발)

  • 윤길원;김홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY (아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합)

  • Park, Sung-Ho;Lee, Chang-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF