적외선 우주배경복사 관측 실험 2(CIBER2) 국제 공동 연구 (KOREAN PARTICIPATION ON THE COSMIC INFRARED BACKGROUND EXPERIMENT 2 (CIBER2))

  • 이대희;박원기;문봉곤;박성준;김민규;김건희;남욱원;표정현;정웅섭;박영식;김일중;한원용
    • 천문학논총
    • /
    • 제30권1호
    • /
    • pp.11-16
    • /
    • 2015
  • First light galaxies have predictable linear clustering, and are expected to produce fluctuations with a characteristic spatial power spectrum, which peaks at an angular scale of ~ 10 arcminutes and in the $1-2{\mu}m$ spectral regions. The Cosmic Infrared Background ExpeRiment 2 (CIBER2) is a dedicated sounding rocket mission for measuring the fluctuations in the extragalactic infrared background light, following up the previous successful measurements of CIBER1. With a 28.5 cm telescope accompanied with three arms of camera barrels and a dual broadband filter on each H2RG (${\lambda}_c=2.5{\mu}m$) array, CIBER2 can measure 6 bands of wide field ($1.1{\times}2.2$ degrees) up to 3 AB magnitudes deeper than CIBER1. This project is leaded by California Institute of Technology/Jet Propulsion Laboratory, collaborating internationally with Institute of Space and Astronautical Science in Japan, Korea Astronomy and Space Science Institute, Korea Basic Science Institute, and Seoul National University. The Korean team is in charge of 1) one H2RG scientific array, 2) ground station hardware and software, 3) telescope lenses, and 4) flight and test bed electronics fabrication. In this paper, we describe the detailed activities of the Korean participation as well as the current status of the CIBER2 project.

치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정 (The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 치료방사선 선형가속기에서 출력되는 광자선의 선속 (flux)에는 gantry head로부터 발생되는 오염전자를 포함하고 있으며, 오염전자의 발생은 주로 gantry head의 부속장비 또는 방사선 치료를 위해 gantry head 밑에 설치되는 부속장치 등에서 광자선과 매질의 전자쌍생성, 또는 컴프톤 산란전자 등의 물리적 현상으로 발생된다. 오염전자는 표면영역의 수cm 깊이의 선량 분포에 영향을 주고 있으며, 이것은 방사선 치료 시 skin-sparing 효과를 감소시키는 등 임상적인 측면에 영향을 주고 있다. 그러므로 선형가속기에서 발생되는 오염전자의 특성을 이해 할 필요가 있다. 본 연구는 선형가속기 (Clinac 1800, Varian )에서 출력되는 15MV 광자 선속에서 조사야의 크기가 0.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$에서 30.0$\times$30.0 $\textrm{cm}^2$ 대해 구리판(Cu)의 부분적 오염전자 제거 능력과, 조사야의 부분 차폐 방법을 이용하여 물팬톰 내의 선량분포의 변화를 측정하므로써 오염전자의 특성을 분석하였다. 그 결과 오염전자는 조사야의 중심축으로부터 넓게 퍼진 cone 모양의 분포를 하고 있었으며, 또한 오염전자가 갖는 평균 에너지는 약 3.0MeV로 나타났다. 그러므로 오염전자는 표면으로부터 2.5cm 깊이까지 분포하였다. 이러한 결과로써 광자선속에 포함된 오염전자를 제거하고 순수한 광자선을 이용한다면 buildup 영역 및 표면선량이 감소되고, 최대선량지점이 좀더 깊어진다.

  • PDF

GPS 반송파 위상을 사용한 편대비행위성 상대위치결정 연구 (Precise Relative Positioning for Formation Flying Satellite using GPS Carrier-phase Measurements)

  • 박재익;이은성;허문범
    • 한국항공우주학회지
    • /
    • 제40권12호
    • /
    • pp.1032-1039
    • /
    • 2012
  • 이 논문에서는 GPS L1/L2 이중 주파수 반송파 위상 관측값을 사용하여 100km 이상의 장기선을 가지는 저궤도 편대비행위성의 상대위치결정 기법을 연구하였다. 더욱 다양한 응용분야로의 유연한 확장을 위해 위성의 동역학 모델을 고려하지 않았고 이중 주파수 GPS 관측값과 오차 모델링을 기반으로 확장칼만필터를 통해 구하고자 하는 미지의 변수를 추정하였다. 편대비행위성 간 기선의 증가로 인해 공통오차로 소거되지 않고 남아있는 전리층 지연 오차는 전리층 매핑 모델을 사용하여 계산하였다. 정수형 미지정수 검색은 정수 최소 자승 조건을 만족하는 미지정수를 보다 빠르고 효율적으로 검색할 수 있는 MLAMBDA 기법을 적용하였다. 결정된 정수형 미지정수의 검정은 비율 테스트를 통해 판정하였다. 제안된 기법의 검증을 위해 편대비행위성 간 상대 기선 거리가 100 km 이상 떨어져 있는 가상의 편대비행위성 시나리오를 구성하여 상대위치결정 정확도를 분석하였다. 분석된 결과를 통해 제안된 기법은 장기선에서의 반송파 위상 미지정수 결정과 mm 수준의 정밀한 상대위치결정이 가능함을 확인하였다.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구 (Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws)

  • 김정기;최영민;이형힉;허원주
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.237-244
    • /
    • 1996
  • 목적 : 의료용 선형가속기의 Independent Collimator는 현재 광범위하게 사용되고 있다. 그러나 방사선량의 계산과 MU(Monitor Unit)의 계산에 사용되는 모든 기본 자료는 대칭 조사면를 기준으로 작성되었기 때문에 independent collimator를 사용한 비대칭적인 조사면의 경우 현재 사용하고 있는 계산 방식을 그대로 적용함에 무리가 있을 것으로 생각된다. 따라서 이러한 의문에 대한 체계적이고 과학적인 검토가 필요할 것으로 사료되어 본 연구를 진행하였다. 대상 및 방법 :본 연구는 Dual Photon Beam(6MV와 15MV)을 산출(産出)하는 선형가속기(Linac 1800, Varian Co)에서 collimator 사용시 산란 방사선의 총채로 표현되어지는 field size factor, beam qualify에 영향을 미치는 HVL와 PDD를 조사하였다. 먼저 field size factor는 water phantom(WP 600C Wellhofer, Germany)내의 Dmax에서 field size $3{\times}3cm$에서 $35{\times}35cm$까지의 방사선량의 변화를 square field로 $1cm^2$씩 증가시켜 가며 0.6cc ion chamber(NE 2571)로 측정하였다. Beam quality는 100cm SSD(source-surface distance)에서 $5{\times}5$, $10{\times}10$, $15{\times}15$$20{\times}20cm$ field size로 0, 3 및 10cm off-axis distance와 dmax 4, 10, 15 및 20cm의 깊이에서 측정하였다. Dose distribution을 분석하기 위하여 film densitometer와 water phantom(IC 10 ion chamber)을 사용, $10{\times}10cm$ field size에서 5, 10 및 15cm의 off-axis distance까지의 방사선량의 분포를 관찰하고 대칭 방사선 조사면와 비교 분석하여 실제 isodose 분포에 미치는 영향을 관찰하였다. 결과: 1) Relative field size factor는 중심 축에서 off-axis lateral distance에 따라 다양하게 변화하였는데 6MV X-선의 경우 최대 $3.1\%$, 15MV X-선의 경우 최대 $5\%$까지의 변화를 보였다. 이때 off-axis factor를 구하여 교정을 하였을 경우 중심 축의 field size factor와 거의 유사한 값에 도달할 수 있었다. 2) Beam qualify의 변화를 관찰하기 위한 실험에서 HVL는 off-axis distance가 멀어질수록 감소하였고 PDD도 off-axis distance가 멀어지고 측정 깊이가 깊어질수록 감소되는 현상을 보였다. 통상적인 방사선 치료시에 이용되는 $5{\times}5cm$ 이상의 field size와 15cm 이내의 깊이에서는 3cm 와 l0cm의 off-axis에서 6MV X-선은 평균 $0.5\%$$2\%$, 15MV X선은 $0.4\%$$1.4\%$의 감소 현상을 보여 큰 편차를 관찰할 수 없었다. 3) Isodose distribution은 off-axis distance가 멀어질수록 depth dose의 증가치가 감소되었으며 특히 central axis의 가장자리 부위에서는 isodose curve의 위축이 확연하였다. 결론 : Independent collimator를 사용하여 비대칭 방사선 치료를 할 경우 MU의 계산은 off-axis factor와 PDD 보정이 필수적이며 임상적으로는 중심 축에서의 과소조사에 대한 정밀한 주의가 필요할 것으로 사료된다.

  • PDF

원형단일결정을 이용한 SPECT의 정량화 연구 (Quantitative Study of Annular Single-Crystal Brain SPECT)

  • 김희중;김한명;소수길;봉정균;이종두
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.163-173
    • /
    • 1998
  • 핵의학 단층촬영기를 이용하여 몸 안에서 일어나는 신진대사, 혈류량 공급, 생화학적 변화, 또는 뇌에서의 도파민 운반체, 수용체 등의 영상을 획득한 후 정량화할 수 있다면 환자의 조기진단뿐만 아니라 치료계획을 세우고 치료경과 등을 객관적으로 측정하는데 매우 유용할 것이다. 그러나 물리적 요소들인 감쇠, 산란, 부분용적 효과, 노이즈, 그리고 재구성 알고리즘 등은 SPECT 의 디자인에 관계없이 영상의 정성적 또는 정량적 결과에 영향을 미친다. 본 논문에서는 뇌 촬영용 단일 결정 SPECT와 뇌 모형 팬텀을 이용하여 물리적 요소들 중 특히 감쇠와 산란의 영향을 정량화하고 보정 방법에 따른 결과를 정량 분석하였다. 산란 보정은 주 에너지 창 140keV$\pm$10% (126~154 keV)와 산란에너지 창 119keV$\pm$6% (112~126keV)를 이용하여 데이터를 획득한 후 산란 에너지 창의 100%를 빼주는 방법을 적용하였다. 영상 재구성은 차단주파수 0.95cycles/cm와 차수 10을 적용한 저역통과 Butterworth 여과기로 여과하여 여과후 역투사 방법으로 재구성하였다. 감쇠 상수는 산란 보정을 하지 않은 경우와 한 경우에 따라 각각 0.12cycles/cm 와 0.15cycles/cm 를 적용하여 뇌 내에서의 균일한 감쇠계수로 가정하고 Chang 방법에 의하여 감쇠에 대한 보정을 하였다. 정량분석을 위해 기저핵이 뚜렷이 보이는 3개의 단층면을 선택하여 기저핵과 그 외 뇌 영역에 관심영역을 구하였다. 산란보정을 하지 않았을 때 감쇠보정을 한 후의 ROI 값은 감쇠 보정전 ROI 값에 비해 기저핵 2.20배 배후 방사능 2.10배였다. 반면에 감쇠보정 후와 감쇠보정 전의 기저핵과 배후방사능의 비율은 매우 비슷했다. 산란보정을 한 후 감쇠보정을 한 ROI 값은 감쇠보정 전 ROI 값과 비교할 때 기저핵 2.69 배 배후 방사능 2.64 배로 뇌 영상의 절대적 정량적 분석을 위해서는 반드시 감쇠 보정이 필요한 것을 보여준다. 기저핵과 배후 방사능의 참값 비율이 6.58, 4.68, 1.86 일 때 산란 보정과 감쇠보정을 한 경우는 참값의 76%, 80%, 82%로 측정하였고 감쇠보정을 하지 않은 경우는 75%, 81%, 81%로 측정하였다. 참값의 비율이 낮을수록 참값에 가깝게 측정하였으나 산란과 감쇠보정을 한 경우에도 참값에 비해 약 20% 의 과소평가를 볼 수 있었다. 이는 본 논문에서 자세히 다루지 않은 부분용적 효과와 재구성 알고리즘 그리고 위에서 적용한 대략적인 감쇠와 산란보정 방법의 원인으로 사료되며 앞으로 더욱 연구되어야 할 분야이다.

  • PDF