• Title/Summary/Keyword: Dual Fan

Search Result 34, Processing Time 0.022 seconds

Optimal Design for a Conic Winglet of a Dual Type Combined Fan (이중구조팬의 Conic Winglet 최적설계)

  • Kim, Jin-Wook;Kim, Woo-Teak;Ryu, Min-Hyoung;Cho, Lee-Sang;Cho, Jin-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.6
    • /
    • pp.468-476
    • /
    • 2016
  • In this study, the conic winglet which is made by rotating wing tip airfoil by each 3 axis is applied to the dual type combined fan to reduce the wing tip leakage loss. Computational Fluid Dynamics is used to calculate the loss and optimum technique is used to get minimum loss. Optimization results shows that total pressure loss coefficient was reduced by 3.4 %, and optimization model was a bended shape at the end of wing forward to pressure side.

The Resonance Characteristic Analysis for Speed Control of Parallel Connected Dual SPMSMs fed by a Single Inverter (단일 인버터로 두 대의 영구자석 동기전동기 병렬운전에 대한 공진특성해석)

  • Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.643-650
    • /
    • 2017
  • This pap4er analyzes resonance characteristics of a slave motor that is not controlled by load and parameter differences between Dual motors during parallel operation in middle-low speed. Dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motor) connected in parallel to a single inverter controlled by the master and slave control in this paper. Based on the stability analysis of the SPMSM for a variation of torque angle, the 6th nonlinear state equation of the torque angle variation in the SIMM(Single Inverter Multi Motor) structure is derived according to a mathematical model for the dual motors. In general, an analysis of the 6th order nonlinear state equation is complex. Therefore, a resonance frequency generated from the slave motor is found from the characteristic equation of the 2nd order system obtained by linearization and model reduction near steady state operation point. Through simulations and experiments, it is confirmed that the stability analysis of the SPMSMs and state equation models are useful for the variation of the torque angle analyzed in this paper.

3D Mesh Encoding Technique Based on Triangle Fan Structure (삼각형 팬 구조에 기반한 3차원 메쉬 부호화 기법)

  • 심재영;이상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10B
    • /
    • pp.1399-1408
    • /
    • 2001
  • 본 논문에서는 삼각형 메쉬(triangular mesh)로 이루어진 3차원 모델의 연결 정보(connectivity data)와 형상 정보(geometry data)를 삼각형 팬(triangle fan) 구조에 기반하여 효율적으로 압축하는 부호화 기법을 제안한다. 첫째로, 연결 정보의 무손실 부호화로 꼭지점 차수 왜곡(vertex degree warping) 기법을 제안한다. 기존의 알고리듬이 연결 정보와 형상 정보를 분리하여 부호화하는데 반해 제안하는 알고리듬은 연결 정보를 부호화하는데 형상 정보를 이용하여 압축 효율을 높인다. 둘째로, 형상 정보를 압축하기 위해 이중 평행사변형 예측(dual parallelogram prediction) 기법을 제안한다. 삼각형 팬 구조를 이용함으로써 기존의 삼각형 스트립(triangle strip) 기반의 알고리듬보다 정확한 형상 예측이 가능하고, 예측 오차가 작아지게 된다. 다양한 3차원 메쉬 모델에 대한 모의 실험을 통하여 제안하는 알고리듬이 기존의 알고리듬보다 우수한 압축 성능을 나타냄을 확인하다.

  • PDF

Comparison of Bone Mineral Density with Pencil Beam and Fan Beam DXA Machine

  • Park, Jeong-Hoon;Lee, Jae-Mun;Youn, Je-Woong;Suh, Tae-Suk;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.425-426
    • /
    • 2002
  • The bone densitometer is to investigate the bone mineral content and density for the osteoporosis assessment by using dual energy X-ray photons. For the clinical verification of the ISOL's OSTEO plus, the clinical study was performed with healthy and non-menopausal 30 female volunteers. The fan-beam DXA machine (Lunar, Expert) was chosen as a reference. After correlation analysis of their bone mineral densities, a strong correlation was obtained. From the results, it is claimed that the new forearm bone densitometer is clinically useful in osteoporosis diagnosis.

  • PDF

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

Upward Influence to Overcome Hierarchical Authority Expectations: A New Approach for Stakeholder Management

  • Fan, Yang;Anantatmula, Vittal
    • Journal of Construction Engineering and Project Management
    • /
    • v.2 no.2
    • /
    • pp.28-35
    • /
    • 2012
  • Critical to project success is effective stakeholder management. This paper presents a challenge for the project manager who uses traditional approaches to manage mid-level stakeholders in an organization. Dual roles of a mid-level stakeholder (as a stakeholder of a project and as an agent of the corporate) may cause problems that would result in difficulties for project managers in identifying the stakeholder's attributes and overcoming hierarchical authority expectation. However, the dual roles of the stakeholder result in its weakness in the project-stakeholder relationship. Can a project leverage its strategic role for effective upward influence by linking project objectives to corporate strategic objectives? To address this research question, case study method was used to gain a deeper understanding of mid-level stakeholder's salience. This research proposes an upward influence strategy to embed a project-stakeholder relationship in a hierarchical stakeholder network.

Induction Motor with Permanent Magnet Rotor (영구자석회전자를 가진 유도전동기)

  • Han, S.D.;Shin, H.J.;Ahn, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.120-122
    • /
    • 2004
  • In this Paper, high efficiency dual air-gap induction motor with permanent magnet rotor is described. The finite element method is used to design the rotor and magnet. And we presented the analysis, construction, experimental results of prototype single phase induction motor with permanent magnet rotor for air-conditioner fan motor.

  • PDF

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Tri-band Microstrip Bandpass Filter Using Dual-Mode Stepped-Impedance Resonator

  • Liu, Haiwen;Lei, Jiuhuai;Zhao, Yulong;Xu, Wenyuan;Fan, Yichao;Wu, Tiantian
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.344-347
    • /
    • 2013
  • This letter presents a compact dual-mode tri-band bandpass filter by using a short-circuited stub-loaded stepped-impedance resonator (SIR) and a short-circuited stub-loaded uniform impedance resonator. Also, a hairpin SIR geometry is introduced to miniature the size of this filter while maintaining excellent performance. The use of a short-circuited stub at the central point of the hairpin SIR can generate two resonant modes in two passbands. Its equivalent circuit structure is analyzed by using the even-odd mode theory. For demonstration purposes, a tri-band filter for the applications of the Global Positioning System at 1.57 GHz, Worldwide Interoperability for Microwave Access at 3.5 GHz, and wireless local area networks at 5.2 GHz is designed, fabricated, and measured.

Development of the Control Algorithm for the Small PEM Fuel Cell Stack (소형 PEM 연료전지 스택의 제어 알고리즘 개발)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.134-141
    • /
    • 2010
  • Small PEM (Proton Exchange Membrane) fuel cell systems do not require humidification and have great commercialization possibilities. However, methods for controlling small PEM fuel cell stacks have not been clearly established. In this paper, a control method for small PEM fuel cell systems using a dual closed loop with a static feedforward structure is defined and realized using a DSP (Digital Signal Processor). The fundamental elements that need to be controlled in fuel cell systems include the supply of air and hydrogen, water management inside the stack, and heat management of the stack. For small PEM fuel cell stacks operated without a separate humidifier, fans are essential for air supply, heat management, and water management of the stack. A purge valve discharges surplus water from the stack. The proposed method controls the fan using double control loops to quicken transient response of the fan thereby improving the supply rate of air. Feedback control to compensate for the voltage change in fuel cell stack improves the response characteristics in fuel cell to load variations. The feasibility of proposed method was proved by the experiments with a 60W small PEM fuel cell system and operation of a notebook computer using this system.