• 제목/요약/키워드: Drying shrinkage crack

검색결과 132건 처리시간 0.02초

복합열화촉진실험 및 장기현장폭로실험에 의한 RC구조물 보수공법의 보수성능평가 (Performance Evaluation of Repair Methods for RC structures by Accelerating Test in Combined Deterioration Chamber and Long-Term Field Exposure Test)

  • 권영진;김재환;한병찬;장승엽
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.349-356
    • /
    • 2006
  • At present, the selecting system and analytic estimation criterion on repair materials and methods of the deteriorated RC structures have not yet been set up in domestic. Under these circumstances, deterioration such as shrinkage crack, corrosion of rebar has been often occurred after repair, and this finally results in too frequent repairs. In this study, three types of repair methods were experimentally investigated by the accelerating test in a combined deterioration chamber and long-term field exposure test. Three types of repair methods applied in this study belong to a group of polymer cement mortar, which is commonly used in repair works. According to the results of this study, durability of repair mortar layers and corrosion properties of recovered rebar could be investigated in short period by the accelerating test in a combined deterioration chamber, which can simulate the condition of repeated high-and-low temperature and repeated dry-and-wet environment, spraying chloride solution and emitting $CO_2$ gas. After 36 month long-term filed exposure test in the coastal area, harmful macro-cracks are observed in the polymer cement mortar layer of some repair methods. These crack are considered to result from drying shrinkage of polymer cement mortar. Also, after 36 month exposure, amount of corrosion area and weight loss of rebar are found to be different according to the types of repair methods.

콘크리트 표면차수벽형 석괴댐(CFRD)의 누수특성에 관한 사례연구 (A Case Study on the Leakage in Concrete Face Rockfill Dam)

  • 방돈석;신창건;이강용;안상로
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.197-202
    • /
    • 2003
  • The leakage quantity through concrete facing of Concrete Face Rockfill Dam(CFRD) is very small due to its low permeability of intact concrete. Even though the concrete facing is well designed and constructed, fine cracks can be generated due to effects of thermal and drying shrinkage. Therefore, it can be said that the leakage from the CFRD is subjected to not permeability of intact concrete but poor joints, cracks and foundation rocks. The Safety of a dam on leakage was evaluated based on the comparison between apparent permeability estimated and leakage quantity measured. The above method can be concluded to give a good direction for the evaluation of safety on CFRD in maintenance aspects as design and construction technology is improved with the accumulation of leakage data.

  • PDF

조강형 Latex Modified Concrete를 이용한 교량상판면 보수용 Overlay Concrete 제조 및 적용에 관한 연구 (Manufacture and Applicasion of High-Early Strength Latex-Modified Concrete to Resurface and Repair Bridge Decks)

  • 엄태선;임채용;백상현;이승재;조윤호;엄주용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.485-490
    • /
    • 2000
  • Because of occuring easily the crack, debond, lutting on asphalts pavement of bredge decks under traffic's heavy weigt load. We investigated the application of latex modified concrete to resurface and repaire bridge decks for preventing the above problems. Here, Using the ordinary portland cement and high early cement, We rested mix design, workability, compressive strength, adhesive power, drying shrinkage, carbonation, and economic estimation etc. We selected the condition of application to resurface and repaire bridge decks and detected high early cement is superior to ordinary portland cement in results of analyzing the application of the repairing bridge decks and economic estimations.

  • PDF

무가압분말충전성형법에 의한 다공성 세라믹스의 제조 및 특성 : I. 알루미나 (The Fabrication and Characteristics of Porous Alumina Ceramics by Pressureless Powder Packing Forming Method : I . Alumina)

  • 박정현;황명익;김동희;최환욱;김용남
    • 한국세라믹학회지
    • /
    • 제36권6호
    • /
    • pp.662-670
    • /
    • 1999
  • Porous alumina was fabricated from pressureless powder packing forming method using powders granulated by spray drying. It was investigated the pore size distribution of fabricated porous alumina. The results of microstructural observation showed that intraganular pore size and intragranular pore size. At 1700$^{\circ}C$ there were no intragranular pores but it showed homogeneous distribution of intergranular pore size. The bending strength and shrinkage increased as porosity decreased. In case of thermal shock resistance sudden decrease of bending strength to $\Delta$T was not shown because intergranular large pore prevented sudden crack propagation.

  • PDF

무가압분말 충전성형법에 의한 다공성 세라믹스의 제조 및 특성 : II. 뮬라이트 & 코디어라이트 (The Fabrication and Characteristics of Porous Ceramics by Pressureless Powder Packing Forming Method ; II, Mullite & Cordierite)

  • 박정현;황명익;김동희;최환욱;김용남
    • 한국세라믹학회지
    • /
    • 제36권6호
    • /
    • pp.671-678
    • /
    • 1999
  • Porous ceramics were fabricated from pressureless powder packing forming method using mullite and cordierite powders granulate by spray drying. The bending strength and shrinkage of porous ceramics were increased and their porosity were decreased with increasing temperature. It showed homogeneous distribution of 2$\mu\textrm{m}$ intergranular pores of mullite at 1400$^{\circ}C$, 2.5$\mu\textrm{m}$ intergranular pores of cordierite at 1300$^{\circ}C$ respedtively. Above that temperature intragranular particles were sintered and sintering by intergranular necking was extremely proceeded. In the test of thermal shock resistance sudden decrease of bending strength to $\Delta$T was not shown because intergranular large pore prevented sudden crack propagation.

  • PDF

솔-젤법에 의한 $Li_2O-ZrO_2-P_2O_5-SiO_2$계 유리 고체전해질의 제조와 그의 이온전도성 (Preparation of $Li_2O-ZrO_2-P_2O_5-SiO_2$ based Glassy Solid Electrolytes by Sol-Gel Process and Their Ionic Conduction)

  • 박강석;김기원;강은태
    • 한국세라믹학회지
    • /
    • 제31권6호
    • /
    • pp.660-670
    • /
    • 1994
  • Transparent, crack-free dried gel monoliths with a composition of LiZr1.5Si2P2O12.5 have been synthesized by the low temperature polymerization of the Sol-Gel technique using metal alkoxides as starting materials. After initial reaction (20~40 min), each metal alkoxide closely paralleled each other during the hydrolysis reactions. The safe drying conditions of gels with no creaks the control of the shrinkage rate. The gels converted into the glass by heat treatment at 75$0^{\circ}C$. FTIR data indicated that the gels were phase separated into silicarich and phosphate-rich regions with the lithium. XRD results showed the formation of crystalline LiH2PO4. The gels dried at 15$0^{\circ}C$ or fired at 75$0^{\circ}C$ contained the residual water. The high ionic conductivity at room temperature for these gels was attributed to the motion of protons.

  • PDF

2중 버블시트를 이용한 한랭기 콘크리트의 단열양생공법 현장적용 (Field Construction Applying the Insulating Method of Moderate-Cold Weather Concreting Using Double Bubble Sheets)

  • 김종;김종백;전충근;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.29-32
    • /
    • 2006
  • Experimental test results of field construction, Cheongju University Educational Liberal Art Building, applying the insulating curing method on slab concrete showed that the quality of concrete in fresh and hardened state satisfied all target values. Temperature history of slab concrete in A and B area secured more than $7.8{\sim}9.2^{\circ}C$ higher than outside atmosphere. After completing certain curing period of time on the surface of the structure, crack occurrence was not found. It is concluded that the preventing vaporization of moisture by the insulating curing method reduces plastic and drying shrinkage as welt as improves durability.

  • PDF

소입경 골재노출콘크리트포장의 환경하중 저항성에 대한 연구 (A Study on the Resistance Against Environmental Loading of the Fine-Size Exposed Aggregate Portland Cement Concrete Pavements)

  • 전범준;이승우;채성욱;배재민
    • 한국도로학회논문집
    • /
    • 제11권2호
    • /
    • pp.99-109
    • /
    • 2009
  • 소입경 골재노출콘크리트포장은 콘크리트 타설 직후 포장표면에 응결지연제를 살포하여 표면으로부터 깊이 2$\sim$3mm 정도의 모르타르 경화를 늦추게 한 후 표면의 모르타르 제거를 통해 굵은골재를 포장표면에 노출시키는 공법이다. 소입경 골재노출콘크리트포장은 타이어-노면 소음이 일반 콘크리트포장보다 4$\sim$5dB(A)정도 작으면서도 적정한 미끄럼저항을 장기간 유지한다는 장점을 가지고 있다. 소입경 골재노출콘크리트포장이 적정 평균조직깊이, 노출도 및 미끄럼저항을 확보하여 강도, 소음저감효과 및 장기간 적정 미끄럼저항성을 유지 하는 것도 중요하지만 성공적인 소입경 골재노출콘크리트포장의 건설을 위해서는 온도, 습도 등의 요인으로 발생하는 환경하중에 대한 내구성이 요구된다. 콘크리트포장은 타설 후 경화과정에서 수분손실 및 초기건조로 인하여 필연적으로 체적변화가수반되며 과도한 체적변화는 콘크리트 균열발생에 주요한 원인이 될 수 있다. 동결융해를 받고 있는 지역에서 제설제를 사용할 경우 표면박리현상이 발생한다. 이러한 균열 및 스케일링은 포장체의 내구성을 저하시키고 미끄럼저항을 감소시켜 장기공용성을 단축시키는 직접적인 요인으로 작용하게 된다. 따라서 본 연구에서는 소입경 골재노출콘크리트포장에 대하여 수분증발로 인한 수축균열 제어 성능 및 제설제를 사용하였을 경우에 반복되는 동결융해작용으로 인한 스켈링에 대해 내구성을 평가하여 환경하중 저항성에 대해 고찰하였다.

  • PDF

단경간 슬래브 중앙 소형박스(개구부)주변의 건조수축 거동 조사 연구 (Investigation of Shrinkage around Small Box of Short Span Slab)

  • 김상연
    • 토지주택연구
    • /
    • 제7권4호
    • /
    • pp.323-328
    • /
    • 2016
  • 아파트의 슬래브에는 전기등박스 매입을 위한 소형 박스 개구부가 존재한다. 이 박스 개구부 주변에는 건조수축으로 인한 균열을 방지하기 위하여 일부에서는 용접철망이나 플라스틱 링 등으로 보강한 상세를 적용하고 있다. 이러한 보강의 타당성을 검토하고 경제적인 대안을 모색하기 위하여 여러 가지 대안으로 보강을 한 슬래브 전기박스 주변의 건조 수축량을 측정하여 분석하였다. 등박스 주변의 보강방법 대안은 기존에 여러 건설사에서 사용되고 있는 용접철망보강안과 플라스틱링 보강안 및 보강을 하지 않은 무보강안 3가지로 하여 비교 분석하였다. 여기서 대상으로 한 아파트는 전용면적 $59m^2$ 이하의 소형평형을 대상으로 하였고 거실 등의 슬래브 하부에 전등박스 주변에 신축량 측정용 팁을 부착하고 컨텍게이지로 신축량을 측정하여 분석하였다. 측정 결과 3가지 대안들에서 상호간의 유의미한 차이가 나타나지 않았고 전반적인 변형량은 $-264{\mu}{\varepsilon}{\sim}+216{\mu}{\varepsilon}$의 범위에 있는 것으로 나타났다. 측정한 변형량의 추이는 거푸집 탈형일 기준치에서 3~5주까지는 조금씩 증가(+)하다가 그 이후 감소하여 수축(-)하는 경향을 띠고 있으며, 한두번의 측정을 제외하고는 변형률이 $+120{\mu}{\varepsilon}$ 이내의 범위에 있는 것으로 나타내고 있어, 콘크리트의 인장 균열 발생 가능성이 매우 거의 없었다.

대단면 터널 라이닝 콘크리트의 균열저감 연구 (A Study on Crack Control of Tunnel Lining Concrete with Large Section)

  • 김완영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.509-512
    • /
    • 2008
  • 라이닝콘크리트란 터널의 영구적인 라이닝으로서 무근 또는 철근콘크리트로 구축되는 터널의 가장 내측에 시공되는 터널의 부재를 말하며. 라이닝의 목적은 터널주변 암반의 풍화방지 및 유수에 의한 지반열화 경감, 터널의 내구성 증대 등이다. 라이닝시 콘크리트는 시공불량, 내부응력, 건조수축 등에 따라 균열을 야기할 수 있으며, 콘크리트 구조물에서 발생하는 이러한 균열은 내구성의 저하와 외관의 손상을 초래하여 사용성을 저하시킬 뿐만 아니라, 균열로 인한보수비용을 증대시킨다. 본 연구는 직경이 15m 이상의 대단면 터널의 라이닝콘크리트의 실제 현장에서 발생한 균열에 대하여 발생하는 균열에 대한 구조, 재료에 대한 분석을 수행하였으며, 그 결과를 제시하므로서 합리적이고 효율적인 대단면 터널 라이닝콘크리트의 균열에 대한 대책을 제시하고자 한다.금번 검토 결과, 구조적 특성에 의한 것이 아님을 알 수 있었으며 다음과 같이 몇가지 원인에 대한대책을 통해 균열을 저감할 수 있을 것이다. 1) 하절기배합인 플라이애쉬 20% 배합으로 변경하면, 수화열 저감효과와 함께 초결시간 지연 효과도 가져올 수 있으므로 연직균열 및 수평균열에 유리한 조건을 만들어 줄 수 있을 것으로 사료된다. 2) 균열이 주로 발생된 S.L 부근의 다짐방법과 관련하여 다음과 같이 개선코자 한다. 즉, 3단과 4단투입구간(間)계면 방지를 위하여 4단 투입구를 통하여 일부 콘크리트를 타설 후 타설중지 상태에서 3단과 4단 투입 콘크리트를 같이 다짐을 실시한다. 이 때 주의할 점은 3단 타설 콘크리트의 초결 이전에 재다짐이 되어야 하므로 전체 시간을 6시간 이내에 완료해야 한다(플라이애쉬 20% 혼입 조건). 3) 일단 S.L 부근까지 콘크리트를 타설한 후, 하단부 콘크리트가 충분히 침강이 일어날 수 있도록 30분 내외 타설을 중지하였다가 후속 콘크리트를 타설토록 한다.

  • PDF