건조공기/에폭시 복합절연물의 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy)

  • 허준;이승수;임기조;정해은;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

군산해역에 있어서 소규모 바다목장화를 위한 해양저질 환경 평가 (Environmental Evaluation of Sediment Quality for Small Scale Marine Ranch around the Gunsan Coastal Areas)

  • 김종화;김종규;박병수
    • 수산해양교육연구
    • /
    • 제20권3호
    • /
    • pp.508-519
    • /
    • 2008
  • Hot air drying is a method that let moistures evaporate by heat exchange between heating air and dry target. This way is dominating more than about 70% of dryers that the use extent is wide fairly, and is established in domestic than dryer that use conduction or radiation etc. Most of research about drying had been emphasized in size of device through analysis for these dry phenomenon plain, heating topology, and aspect of form and so on by dry target's special quality, and research about device development or waste heat withdrawal technology in energy utilization efficiency side is slight real condition. Therefore, in this study, Investigated numerically about thermal efficiency elevation that is leaned against as that change the temperature of inlet and outlet in heat exchanger of the hot air drying tower.

An Experimental Study of the Airside Performance of Slit Fin-and-Tube Heat Exchangers under Dry and Wet Conditions

  • Chang, Keun-Sun;Long, Phan-Than
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.7-14
    • /
    • 2009
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performances. The purpose of this study is to investigate the effects of condensate retention on the air-side heat transfer performance and flow friction for various flow and geometric conditions. Total of twelve samples of slit and plate fin-and-tube heat exchangers are tested under dry and wet conditions. The thermal fluid measurements are made using a psychrometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are heat transfer coefficients in terms of Colburn j-factors and friction factors, and these data are compared with the existing correlations.

드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구 (A study on design for free cooling system using dry cooler)

  • 윤정인;백승문;허정호;김영민;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1027-1031
    • /
    • 2014
  • 외기냉수냉방 시스템은 공조나 산업공정에 사용되는 냉수를 저온의 외기를 이용하여 냉각하는 시스템으로 에너지를 절감하기위해 사용되며, 냉각시스템과 외기와 냉수가 열교환을 하는 드라이쿨러로 구성되어있다. 외기냉수냉방 시스템은 지속적인 냉방이 필요한 곳에 에너지절감효과가 뛰어나나 국내의 경우, 외기냉수냉방 시스템에 설계 기준과 자료가 미비하다. 따라서 본 연구에서는 상용프로그램 HYSYS를 이용하여, 드라이쿨러를 이용한 외기냉수냉방 시스템의 요소변화에 따른 성능을 비교 분석했으며 그 결과는 다음과 같다. 드라이쿨러의 냉각능력은 외기온도, 요구냉수온도, 열교환기의 LMTD (Logarithmic Mean Temperature Difference, 대수평균온도차)에 따라 변한다. 드라이쿨러는 외기온도가 낮을 수록 그 냉각능력이 증가하며, LMTD가 낮은 드라이쿨러가 LMTD가 높은 것에 비하여 고온의 외기온도에서 사용이 가능하였다. 외기온도가 극히 낮은 지역에서는 글리콜이 함유된 부동액을 사용해야하며 국내의 외기온도를 고려하였을 때, 글리콜농도 34%의 부동액이 적절한 것으로 판단된다. 냉동기에 적용될 작동유체의 경우, R22, R134a, R407C의 압축일을 비교했으며, R134a가 환경관련 규제와 에너지 사용측면에서 우수한 냉매로 사료된다.

경제성 평가를 이용한 프리쿨링시스템의 국내 적용성 연구 (A Study on Application of the Free Cooling System with Dry Cooler Using Economic Evaluation)

  • 윤정인;손창효;김희민;김영민
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.50-55
    • /
    • 2015
  • Recently, because of the deterioration of the nuclear generating station and increase of the cooler and heater, energy problem is increasing. To save the energy, the free cooling system is developed. The free cooling system is that cool the water to use cooled air in winter and is used in industrial process or data center. Yoon check the energy of free cooling system with dry cooler in korea. In this study, the value of the free cooling system with dry cooler is confirmed through using the NPV that is economic evaluation. when temperature degree of the cooled water is 10, in Chuncheon and Seoul the value is the most high. When temperature degree of the cooled water is 20, in Ulsan the value is the most high. As the result, because the using the temperature degree of the cooled water is high in the industrial process, the free cooling system is advantageous in korea.

한국산(韓國産) 죽재(竹材)의 동력학적(動力學的) 성질(性質) (Dynamic Mechanical Properties of Bamboos in Korea)

  • 홍병화
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권1호
    • /
    • pp.45-54
    • /
    • 1988
  • This study was carried out to investigate the fiber length, fiber width and fiber thickness on the longitudinal direction by the parts of culm and also specific gravity in air dry, dyna.mic mechanical properties and internal frictions by the internode and the node in Phyllostachys bambusoides Phyllostachys nigra var. henonis and Phllostachys edulis which were grown in Korea. The results obtained were as follows; 1. The variations of fiber length and fiber width on the longitudinal direction had a tendency to increase slightly from the butt and then to decrease toward the top. but there was not a definite variation for fiber thickness according to the parts of culm. 2. The specific gravity in air dry of internode was increased from the butt toward the top, but the specific gravity in air dry of node was not correlations with the parts of culm. 3. Dynamic Young's modulus of internode on the longitudinal direction was increased according to the heights of culms within each species, and there were in order of P. edulis P. nigra var. henonis and P. bambusoides. 4. Correation coefficients between the specific gravity and the dynamic Young's modulus were 0.837 in P. bambusoides 0.871 in P. nigra var. henonis and 0.935 in P. edulis and there was also highly significant for dynamic Young's modulus between the specific gravities in air dry. 5. There were not correlations between the internal frictions and the parts of internode.

  • PDF

준평등전계중 Dry Air내 산소의 농도에 따른 절연파괴 및 연면방전 특성 연구 (A Study on Characteristics of Insulation Breakdown and Surface Discharge by the Oxygen Concentration in the Dry Air in Quasi-Uniform Field)

  • 백종현;석정후;최병주;배성우;김기채;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.41-46
    • /
    • 2015
  • This study was conducted to discover a substitute of $SF_6$ gas. $SF_6$ gas is widely used across the industries. Thanks to superior electrical properties, in particular, it has been commonly used in electrical industry. However, there have been a lot of studies on its serious effect on global warming. As a substitute of this synthetic gas, a mixture of dry air and $N_2/O_2$ was chosen in this study. In case of $N_2/O_2$, dielectric strength differs depending on the mixing ratio. This study examined dielectric breakdown and flashover after adjusting oxygen percentage in the dry air. This test was conducted in a quasi-uniform electric field depending on pressure, oxygen concentration and gas mixtures. The test results found that dielectric voltage and flashover voltage were the highest at a certain oxygen concentration. It is the results of this photoionization and electron attachment of oxygen.

자동차 흡기 에어필터의 여재 및 성능에 관한 연구 (A Study on the Filter Media and Performance of Intake Air Filter for Vehicular Engine)

  • 안병찬;오명도
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.8-15
    • /
    • 2004
  • Since the vehicle is regarded as the third living space, the comfortable conditions are required in the passenger compartment. For this reason, customers are concerned about the filtering performances and the importance of filter media has been greatly placed. Therefore the dust holding capacity, the efficiency of these filter media (dry paper, wet paper, non-woven) and the configuration of air filter for vehicle were measured in this study. The following results were obtained on the basis of air filter test. It shows that the thickness and poresize of filter media should be lower for the higher efficiency. The measurement result shows that the performance of round shape filters are higher than the square shape filters. The dust holding capacity of the wet paper and the non-woven paper is higher than the dry paper. As a result, this research can provide an important design parameter and product guidance of the intake air filter for vehicular engine.

$SF_6$와 이종절연재의 연면방전 특성 비교 (The Comparisons of the Surface Flashover Characteristics at $SF_6$ and the various insulation media.)

  • 이정환;박혜리;박숭규;최영길;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1400_1401
    • /
    • 2009
  • In this paper describes the comparisons of the surface flashover characteristics according to the change of the insulation media by experimental GIS(Gas Insulated Switchgear) chamber in accordance with change of pressure(P) and electrode distance(d). The using insulation medias are $SF_6$, Dry-Air, I-Air(Imitation Air, $N_2$ : $O_2$ = 79[%] : 21[%]), $N_2:O_2$ mixture gas and pure $N_2$. In this study, in order to compare the properties $SF_6$ and order insulation gas, we investigated the properties of the various insulation media with a knife to knife electrode under ac high voltage application. The gas pressure was changed from 1 to 5[atm]. as a result, it was found that dielectric strength is $SF_6$ > I-Air > Dry-Air and the best environmental preservation gas is Dry-Air.

  • PDF

건식 저온 압축 공기를 이용한 절삭유 대체형 가공 공정 방식에 관한 연구 (A Study on the Environment Conscious Machining Process Using Compressed Dry Cooling Air)

  • 강재훈;송준엽;박종권;노승국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 2003
  • Used cutting fluid from machining processes is harmful to both environment and human health. Chemical substances that provide the lubrication function in the machining process are toxtc to the environment if the cutting fluid is released to soil and water and caused serious health problems to workers who are exposed to the cutting fluid in both liquid and mist form. Recently. cost of using cutting fluid is increasing as the number and the extensiveness of environmental protection laws and regulations increase. Therefore, the use of cutting fluid in machining processes place an enormous burden on manufacturing companies to cover the additional costs associated with their use and protection of our environment. Current trends in manufacturing are focused on minimizing or eliminating the use of metalworking fluids in machining processes. And the increased costs for the disposal of waste products (swarf, coolants and lubricants), especially in industrially developed countries, has generated interest in dry machining. A variety of new techniques are testimony that new technology has rationalized further efforts to research and implement dry machining processes. This paper presents the developed equipment, the process optimization and the applications in the field of surface grinding for the new cryogenic dry machining using a compressed cooling air. The investigated new machining process method shows many advantages compared to conventional techniques with cutting fluid.

  • PDF