• Title/Summary/Keyword: Dry type

Search Result 1,612, Processing Time 0.025 seconds

A comparison of detergency and dimensional stability between wet cleaning and dry cleaning (물세탁과 드라이클리닝의 세탁성능과 형태안정성 비교)

  • Kwak, Soo-Kyung;Kim, Ah-Ri;Oh, Hwawon;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.1
    • /
    • pp.181-189
    • /
    • 2019
  • The washability, redeposition, fill power, and fabric damage of wet cleaning and dry cleaning solvents were measured to identify the optimal type of washing that would increase washability while maintaining dimensional stability. The soiled fabric is a polyester cotton blend and the types of soil were wine, blood, make-up and sebum with carbon black. Petroleum and silicone solvents were used in dry cleaning. Results from this study are as follows. First, detergency is significantly influenced by the type of washing and type of soil. Wet cleaning is superior to dry cleaning. Wet cleaning shows a strong washing performance against hydrophilic soils, whereas, dry cleaning is stronger against hydrophobic soils. Second, redeposition is significantly affected by the type of washing, fabrics, and soils. Redeposition occurred little on cotton during wet cleaning, but showed a high rate for nylon. However, when the two types of fabric were dry cleaned, redeposition occurred on both types. Third, the fill power of duck-down is very affected by the type of washing. Resilience is the best in wet cleaning; and in dry cleaning, petroleum solvents showed a higher resilience when as compared to silicone solvents. Last, the level of fabric damage to cotton fabrics is highly influenced by the type of washing. Wet cleaning damages cotton fabrics significantly more than dry cleaning. For dry cleaning, petroleum solvents damage these fabrics slightly more than silicone solvents. In conclusion, the type of soil must initially be identified to determine the optimal type of washing. Special caution is required when textiles with particulate soil and nylon are washed. When considering the resilience of duck-down clothing, wet cleaning is more appropriate than dry cleaning. Dry cleaning, especially when using silicone-based solvents, is more suitable than wet cleaning for maintaining the shape of clothing.

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger (건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구)

  • 김병조;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

Effect of evaporation-induced osmotic changes in culture media in a dry-type incubator on clinical outcomes in in vitro fertilization-embryo transfer cycles

  • Chi, Hee-Jun;Park, Jun-Sang;Yoo, Chang-Seok;Kwak, Su-Jin;Son, Ho-Jeong;Kim, Seok-Gi;Sim, Chae-Hee;Lee, Kyeong-Ho;Koo, Deog-Bon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.47 no.4
    • /
    • pp.284-292
    • /
    • 2020
  • Objective: This study investigated whether adding outer-well medium to inhibit osmotic changes in culture media in a dry-type incubator improved the clinical outcomes of in vitro fertilization-embryo transfer (IVF-ET) cycles. Methods: In culture dishes, the osmotic changes in media (20 µL)-covered oil with or without outer-well medium (humid or dry culture conditions, respectively) were compared after 3 days of incubation in a dry-type incubator. One-step (Origio) and G1/G2 (Vitrolife) media were used. Results: The osmotic changes in the dry culture condition (308 mOsm) were higher than in the humid culture conditions (285-290 mOsm) after 3 days of incubation. In day 3 IVF-ET cycles, although the pregnancy rate did not significantly differ between the dry (46.2%) and humid culture (51.0%) groups, the rates of abortion and ongoing pregnancy were significantly better in the humid culture group (1.5% and 49.5%, respectively) than in the dry culture group (8.3% and 37.8%, respectively, p<0.05). In day 5 IVF-ET cycles, the abortion rate was significantly lower in the humid culture group (2.2%) than in the dry culture group (25.0%, p<0.01), but no statistically significant difference was observed in the rates of clinical and ongoing pregnancy between the dry (50.0% and 25.0%, respectively) and humid culture groups (59.5% and 57.3%, respectively) because of the small number of cycles. Conclusion: Hyperosmotic changes in media occurred in a dry-type incubator by evaporation, although the medium was covered with oil. These osmotic changes were efficiently inhibited by supplementation of outer-well medium, which resulted in improved pregnancy outcomes.

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

Screw-type Dry Vacuum Pump Technology and Application in Semiconductor Process (스크류 형 건식진공펌프 기술 현황 및 응용)

  • Noh, Myung-Keun;Hwang, Tae-Kyoung;Park, Jea-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.292-301
    • /
    • 2008
  • As the industry requiring clean vacuum condition like semiconductor and display manufacturing expands, importance of dry vacuum pumps has been increased. Screw-type dry vacuum pump, occupying major share with multi-stage roots pump in dry-pump market, has big strength specially in harsh application area accompanying serious by-product accumulation. Recently, development in screw-type pump has been focused on improving energy efficiency. In this article, technology of screw-type dry vacuum pump is reviewed and the requirement for actual industrial application is considered. In addition, the expected evolution for screw-type dry pump in near future is also described.

Effect of NaCI Concentration on Germination and Seedling Growth of Italian Ryegrass(Lolium multiflorum L.) (NaCl 농도가 이탈리안 라이그래스의 발아와 유묘생장에 미치는 영향)

  • 이강수;최선영;최철원
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.3
    • /
    • pp.340-350
    • /
    • 1995
  • This study was conducted to obtain the basic information for the salt stress of Italian Ryegrass. Fourteen cultivars including 7 diploid and 7 tetraploid were subjected to eight levels of NaCl treatments during germination and early seedling stages. Germination percentage decreased remarkably over 300mM of NaCl concentration. The NaCl concentration that inhibited germination of 50% of the viable seeds in the cultivars was 344mM. The decreasing degree of germination percentage was higher in tetraploid type than in diploid type. The varietal difference of germination percentage was shown to be very conspicuous as the NaCl concentration increased. Top dry weight in 166 mM NaCl was decreased by 50% compared with that of control. Inhibition of NaCl appeared to be more in early seedling stage than in germination stage. Top dry weight of cultivars in NaCl stress was not related with germination capacity. Root dry weight in 148mM NaCl decreased by 50% compared with that of control. Root dry weight of cultivars was significantly correlated with top dry weight in NaCl treatment. Top dry weight and root dry weight was higher in diploid type than in tetraploid type at each 8 levels of NaCl concentration. Total chlorophyll content increased with the increase of NaCl concentration and the degree of increase in chlorophyll a was higher than that in chlorophyll b. Chlorophyll a was higher in tetraploid type than in diploid type. But chlorophyll b was higher in diploid type than in tetraploid type. There were significant correlation between chlorophyll a and top dry weight of cultivars over 150mM of NaCl concentration. Free proline content accumulated remarkably in NaCl treatment compared with control and was not difference between diploid type and tetraploid type. Free proline content of cultivars was not related with top dry weight in NaCl treatment.

  • PDF

A Case Study of Type-II Diabetes Mellitus: Two Patients with Taeumin's Dry-febrile Symptom (태음인(太陰人) 조열증(燥熱證)으로 진단된 2형 당뇨병 환자 치험(治驗) 2례)

  • Lee, Seung-un;Hwang, Joo-won;Lee, Won-chul
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.509-519
    • /
    • 2017
  • Objectives: This study describes how two patients diagnosed with type-II diabetes mellitus were successfully treated using herbal medicine. Methods: The patients were given Yuldahanso-tang to reduce the effects of Taeumin's dry-febrile symptom. Results: Type-II diabetes mellitus symptoms experienced by patients with Taeumin's dry-febrile symptom included thirst, fatigue, weight loss, and numbness in the hands and feet. After administering Yuldahanso-tang, all numerical levels for blood sugar, glycated hemoglobin (HbA1c), glycosuria, and proteinuria recovered to within normal levels. Conclusions: Treatment of patients with Taeumin's dry-febrile symptom and type-II diabetes mellitus with Yuldahanso-tang was effective, and this new evidence supports the use of herbal medicine for treating such patients.

Clinical Study of Different Effect between Trigger Point Needling and Remote Acupuncture Point Needling on Tension-type Headache (긴장성 두통에 대한 동통유발점 자침과 원위취혈 자침의 치료효과에 대한 임상적 비교 연구)

  • Lee, Sang-Moo;Hwang, Kyu-Sun;Han, Hee-Cheol;Jeong, Hyung-Seob
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • Purpose ; Iension-type headache is the most common headache. The effect of acupuncture for headache is already known, but the methods and technique of acupuncture is varied. Choice of acupuncture points is mostly relied on experience. Moreover, objective evaluation of acupuncture effects is lacking. Objective ; The objective of this study is to assess the difference of effects between dry needling on trigger point and dry needling on remote acupuncture point. The patients who were diagnosed as tension-type headache and administrated herb-medication were divided into two groups: Trigger point dry needling group and remote acupuncture point dry needling group, matching in sex, age. The degree of pain was measured by visual analogue scale(VAS) two times, before and after dry needling. Conclusion ; VAS showed significant decrement after dry needling on tension-type headache in both groups, but there was no statistically significant difference between two groups according to sex, age and duration. In addition, it is not statistically approved that there exists the difference of VAS between two groups about the treatment effects.

  • PDF