• Title/Summary/Keyword: Dry operation

Search Result 375, Processing Time 0.033 seconds

Dehydriding Performance in a Depleted Uranium Bed (감손 우라늄 베드 수소 탈장 성능)

  • KOO, DAESEO;KIM, YEANJIN;YUN, SEI-HUN;CHUNG, HONGSUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • It is necessary to store and supply hydrogen isotopes for Tokamak operation. A storage and delivery system (SDS) is used for storing hydrogen isotopes as a metal hydride form. We designed and fabricated a depleted uranium (DU) bed to store hydrogen isotopes. The rapid storage of hydrogen isotopes is very important not only for safety reasons but also for the economic design and operation of the SDS. The delivery rate at the desorption temperatures without the operation of a dry pump was analyzed in comparison with that with the operation of the dry pump. The effect of the initial desorption temperatures on the dehydriding of the DU without the operation of the dry pump was measured. The effect of the initial desorption temperatures on the dehydriding of DU with the operation of the dry pump was also measured and analyzed. The primary pressure on the desorption temperatures without the operation of the dry pump was analyzed in comparison with that with the operation of the dry pump. The temperature gradient of the coil heater and the primary vessel was also analyzed. Our results will be used to develop pilot scale hydrogen isotope processes. It was confirmed that dehydriding of a medium-scale DU bed has enabled without the operation of the dry pump.

Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas (자연급기 무가습 연료전지의 Dry-out조건)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

Job Hazard Analyses for Musculoskeletal Disorder Risk Factors in Pressing Operations of Dry-cleaning Establishments

  • Park, Jung-Keun
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.389-393
    • /
    • 2016
  • Job hazard analyses were conducted to assess exposure to musculoskeletal disorder (MSD) risk factors in seven workers of three dry-cleaning establishments. In accordance with the Washington State Ergonomics Rule, the analyses were performed in two separate steps: (1) observation and checklist approaches were made to identify a "caution zone job" in the seven workers' pressing operations across the three shops; and (2) detailed posture and motion analyses were undertaken to determine a "MSD hazard" in one worker's operation using a video technique. One "caution zone job" was identified and it was the pressing operation job in which five physical risk factors were found in the pressing operations. The detailed analyses confirmed that one "MSD hazard", i.e., awkward posture in shoulders, was prevalent in the pressing operations of the three dry-cleaning facilities. It would be desirable to reduce MSD risk factors including awkward shoulder posture in the dry-cleaning industry.

Development of the Vacuum Drying Process for the PWR Spent Nuclear Fuel Dry Storage (경수로 사용후핵연료 건식저장을 위한 진공건조공정 개발)

  • Baeg, Chang-Yeal;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.435-443
    • /
    • 2016
  • This paper describes the development of a dry operation process for PWR spent nuclear fuel, which is currently stored in the domestic NPP's storage pool, using a dual purpose metal cask. Domestic NNPs have had experience with wet type transportation of PWR spent nuclear fuel between neighboring NPPs since the early 1990s, but no experience with dry type operation. For this reason, we developed a specific operation process and also confirmed the safety of the major cask components and its spent nuclear fuel during the dual purpose metal cask operation process. We also describe the short term operation process that was established to be completed within 21 hours and propose the allowable working time for each step (15 hours for wet process, 3 hours for drain process and 3 hours for vacuum drying process).

Analysis and Design of Nuclear Spent Fuel Dry Storage System under Irregular Operation (사용후 핵연료 건식저장장치의 비정상 운영조건의 해석과 설계)

  • Song, Hyung-Soo;Min, Chang-Shik;Yoon, Dong-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.381-384
    • /
    • 2004
  • Delaying and objection for the construction of storage spent-fuel disposal has prompted to consider expanding on-site storage of spent reactor fuel since it can eliminate the need for costly and difficult shipping and control of the spent fuel completely under the direction of the owner-utility. The dry storage unit developed in Canada can accommodate Korea heavy water reactor fuel elements and become a candidate for the Korean market. In this paper, finite element analyses were carried out in order to investigate the structural behavior of the nuclear spent fuel dry storage system, which is subjected to impact loads such as collision of a truck load and dropping of flask under the irregular operation.

  • PDF

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

A Study of Adoption on the Concept of Monthly Probable Maximum Precipitation (월 PMP 개념의 적용에 관한 연구)

  • Choi, Han-Kyu;Kim, Nam-Won;Choi, Yong-Mook;Yoon, Hee-Sub
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.241-248
    • /
    • 2001
  • Normally at a flood season the operation of the dam depends on a short range weather forecast that makes many difficulties of the management at a dry season. It is needed to study the pattern of the long period rainfall. The concept of PMP(Probable Maximum Precipitation) was used for designing dam. From the concept, this study is applied the concept of monthly probable maximum precipitation for operating dam. It can be possible to let us know the appropriateness of a limiting water level at a rainy season. For the operation of dam at a dry season this study can predict roughly the flood season's pattern of precipitation by month or period, therfore the prediction of precipitation can rise efficient operation of a dam.

  • PDF

Consumed-Power and Load Characteristics of Potato Harvesting Operation in Dry Field (건답에서 감자수확작업의 소요동력 및 부하특성)

  • Lee, Ju-Yeon;Hwang, Seok-Joon;Nam, Ju-Seok;Kim, Jeong-Gil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.89-99
    • /
    • 2020
  • This study analyzed the load and the consumed power characteristics of a potato harvesting operation in a dry field. The potato harvesting operation was performed using an underground crop harvester mounted on an agricultural tractor with a rated engine power of 23.7 kW. The rotational speeds and the torque of the engine output shaft, rear axle, and power take-off (PTO) shaft were measured under various working conditions. The load spectrum and the consumed power were analyzed using the measured data. The results show that the consumed power of the rear axle increased as the working speed increased, while that of the PTO shaft decreased. The consumed power of the engine output shaft showed a similar trend with that of the PTO shaft, but the torque deviation was larger in the load spectrum. The results of previous studies were used to compare herein the consumed power and the load characteristics of the harvesting, rotary, and plow operations in a dry field. PTO and tractive power were highly consumed in the plow and rotary operations, respectively. The consumed power of the PTO shaft and the rear axle in the harvesting operation were 29-41% and 18-23% of the engine power, respectively. Compared to those in the rotary and plow operations, the engine power was relatively evenly distributed to the PTO shaft and rear axle in the harvesting operation.

Spent fuel simulation during dry storage via enhancement of FRAPCON-4.0: Comparison between PWR and SMR and discharge burnup effect

  • Dahyeon Woo;Youho Lee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4499-4513
    • /
    • 2022
  • Spent fuel behavior of dry storage was simulated in a continuous state from steady-state operation by modifying FRAPCON-4.0 to incorporate spent fuel-specific fuel behavior models. Spent fuel behavior of a typical PWR was compared with that of NuScale Power Module (NPMTM). Current PWR discharge burnup (60 MWd/kgU) gives a sufficient margin to the hoop stress limit of 90 MPa. Most hydrogen precipitation occurs in the first 50 years of dry storage, thereby no extra phenomenological safety factor is identified for extended dry storage up to 100 years. Regulation for spent fuel management can be significantly alleviated for LWR-based SMRs. Hydride embrittlement safety criterion is irrelevant to NuScale spent fuels; they have sufficiently lower plenum pressure and hydrogen contents compared to those of PWRs. Cladding creep out during dry storage reduces the subchannel area with burnup. The most deformed cladding outer diameter after 100 years of dry storage is found to be 9.64 mm for discharge burnup of 70 MWd/kgU. It may deteriorate heat transfer of dry storage by increasing flow resistance and decreasing the view factor of radiative heat transfer. Self-regulated by decreasing rod internal pressure with opening gap, cladding creep out closely reaches the saturated point after ~50 years of dry storage.

Research on the Actual Condition of Rotary Tilling & Rotary Power Requirement in the Central Area (중부지방에서의 로터리 경운작업 실태조사 및 경운부하)

  • Myung, Byung-Su;Lee, Hyun-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.2
    • /
    • pp.79-83
    • /
    • 2009
  • In this study, actual state of operation of rotary tillage was surveyed in the central part of Korea which includes 29 rural community around Asan city, Choongnam principal. 29 heads of the village and 44 farmers were surveyed at the field with a questionnaire on the operation of rotary tillage with farm tractors. Power requirement of rotary tillage operation was measured at the field of each farmers during rotary tilling operation in the central part of Korea. Summaries of this study are summarized as follows. 1) Operations of tillage and land preparation were found to be carried out with farm tractors by 98 percents which are results of the survey on 29 heads of the village and 44 farmers. 2) More than half of the farms had tractors with horsepower more than 38 kW which states that most tractors were supplied in middle and large size. 3) The case of applying secondary tillage after the first primary tillage were 79 percent among the most of operations of tillage and field preparation. Rotary tillage were carried out on the most of wet paddy fields and only 14 percent of dry fields were cultivated with rotary tillage. 4) 63.6 percent of farm tractors were surveyed to meet the recommended field capacity on tillage operation by the government which were ranged from 15.1 to 34.9 ha. And the field capacity of these farm tractors were greater than that of annual total area of operation field, 13.2ha (data from Information of agricultural machinery, National agricultural products quality service, Korea), which states the utilization of agricultural machinery was high in the area surveyed. 5) 46 percent of farmers changed the blade of rotary implement when they used it over the field capacity of rotary blade of 33 ha which is the area of field for rotary operation per a blade change. 55 percent of farmers changed the rotary blade more than once per two years. 6) The required power for rotary operation of each farm tractors were measured as 17.206 kW at untilled paddy field and 34.989 kW at untilled dry field on the average, respectively. The required power for rotary operation was measured as 28.248 kW on the average at the paddy field which had been plowed once and 28.015 at the paddy field that had rotary tillage operation. Untilled dry field showed the highest value of the required power for rotary operation.

  • PDF