• 제목/요약/키워드: Dry joint

검색결과 105건 처리시간 0.022초

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

최근 20년간 턱관절 장애의 침 치료 연구에 대한 계량서지학적 분석 (Bibliometric Analysis of Research Trends of Acupuncture on Temporomandibular Disorders Treatment over the Past 20 Years)

  • 김희준;조재흥
    • 한방재활의학과학회지
    • /
    • 제34권1호
    • /
    • pp.49-64
    • /
    • 2024
  • Objectives By bibliographically analyzing acupuncture treatment studies for temporomandibular disorders over the past 20 years, we found an overview of global trends and a new perspective on future research directions. Methods We searched on the Web of Science webpage through the formula (TS=[temporomandibular] OR TS=[craniomandibular] OR TS=[jaw]) AND (TS=[*acupuncture] OR TS=[dry needl*] OR TS=[warm needl*] OR TS=[thread embed*]) AND (PY=[2003-2022]). And it was analyzed by year, research field, academic journal, country, research institute, author, and keyword. Results 194 papers were searched, and 92 papers were finally selected. The number of papers published over the past 20 years has been on the rise. Research has been the most active in the field of Dentistry Oral Surgery Medicine. Brazil published the most papers. And by institution, Universidade de Sao Paulo published the most papers. Among the authors, Fernández-de-las-Peñas has published the most papers. In the analysis by keyword, the top five keywords were temporomandibular joint disorder, acupuncture, myofascial pain, pain and management. Conclusions This study will provide useful guidelines for setting the direction of research by referring to the research status and keyword analysis when conducting research on the acupuncture on temporomandibular disorder in the future.

복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구 (A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems)

  • 장현옥;장일영
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.329-338
    • /
    • 2024
  • 연구목적: 본 연구는 긴장방식을 복합적으로 적용한 세그멘탈 PSC U형 거더에 대한 해석적 거동을 기반으로 실대형 실험체의 휨 거동 결과를 평가하여 거동의 안전성을 검증하고자 한다. 연구방법: 도로교설계기준 한계상태설계법의 사용한계 및 극한한계상태 설계 결과를 바탕으로 40m 실대형 실험체의 가력하중을 산정하고 이에 대한 4점재하방식 정적 하중재하 실험을 수행하였다. 연구결과: 설계하중, 균열하중 및 극한하중이 작용할 때 해석적 처짐값 대비 97.1%, 98.5% 그리고 79.0%에 해당하는 실험체 처짐이 발생하였다. 설계하중, 균열하중 및 극한하중이 작용할 때 균열계는 각 연결부에서 0.009~0.035mm, 0.014~0.050mm, 6.383~5.522mm로 계측되었다. 결론: 균열하중 재하시까지 실험체는 탄성적으로 거동하였고 균열발생 후 극한하중까지 변형율-경화현상을 보이며 작용하중에 대하여 휨 저항 거동이 뚜렷이 나타났음을 확인하였다. 실대형 실험체 연결부(Dry Joint) 균열은 시설물 상태평가 B등급 기준 25% 미만의 결과로써 연결부의 탄성적 거동을 확인하였고 극한하중 제거 후 최종적 잔류 변형은 0.114mm로써 세그먼트 연결부의 안정적 거동을 확인하였다.

부산 남항 해저퇴적물 중 유기오염물질 분포 특성에 관한 연구 (The Spatial Distribution of Harmful Chemical Substance in Sediment Around Busan Southern Port)

  • 민병규;이종혁;주미조;조천래;조현서
    • 해양환경안전학회지
    • /
    • 제26권2호
    • /
    • pp.206-218
    • /
    • 2020
  • 부산 남항은 도심 속의 다기능 항만으로 공동어시장, 선박수리소, 연근해 및 원양어선 접안시설 등이 설치되어 산업 활동이 활발하다. 산업 활동으로 인해 발생한 유해화학물질이 해저퇴적물에 지속적으로 유입되어 축적되면 수생생태계와 인간에게 영향을 끼칠 수 있다. 따라서 부산 남항에서 2013년 11월(1차), 2014년 11월(2차)에 8개 정점을 선정하여, 해저퇴적물 중 다환방향족탄화수소류(PAHs), 폴리염화비페닐(PCBs), 부틸계유기주석화합물(BTs)를 분석하여 부산 남항의 농도분포 특성 및 유입원을 밝혀내고자 하였다. 연구 지역에서 PAHs의 평균 농도는 1차, 2차 조사에서 각각 4174.0 ng/g-d.w., 1919.0 ng/g-d.w., PCBs의 평균 농도는 1차, 2차 조사에서 각각 166.3 ng/g-d.w., 21 ng/g-d.w.를 보였으며, BTs의 평균 농도는 1차, 2차 조사에서 각각 50.9 ng/g-d.w., 30.8 ng/g-d.w.를 나타내었다. 유기오염물질의 검출농도는 1차에 비해 2차에서 해저퇴적물 수거로 인해 낮아지는 경향을 보였으며, 본 조사에서 PAHs, PCBs, BTs 유입원은 각각 연소기원, 육상기원, 도시하수 또는 산업폐수에 의한 기원을 확인 할 수 있었다.

Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

  • Kocasarac, Husniye Demirturk;Celenk, Peruze
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.99-107
    • /
    • 2017
  • Purpose: Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Materials and Methods: Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. Results: The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. Conclusion: The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

샌드위치와 적층판을 접착한 단일겹침 체결부의 고온습도 강도특성 연구 (Strength of sandwich-to-laminate single-lap bonded joints in elevated temperature and wet condition)

  • 최배현;권진회;최진호;신상준;송민환
    • 한국항공우주학회지
    • /
    • 제38권11호
    • /
    • pp.1115-1122
    • /
    • 2010
  • 본 논문에서는 샌드위치-적층판 단일겹침 접착 조인트의 정적강도를 시험을 통해 연구하였다. 접착제의 두께(3종류 : 0.2, 2, 4 mm)와 환경조건(2가지 : 상온, 고온흡습)을 변화시키면서 총 38개의 시편을 제작하여 시험을 수행하였다. 시험 결과, 접착제의 두께가 0.2mm에서 2 mm 와 4 mm로 증가함에 따라 체결부의 파손강도가 각각 16% 와 30% 정도 감소하는 것으로 나타났다. 반면 고온흡습 환경에서의 파손강도는, 접착제의 두께가 0.2mm인 경우를 제외하면, 접착제의 열화현상이 적층판과 샌드위치 면재의 층간분리 혹은 층내분리 파손을 지연시켜, 상온건조 환경에 비해 약 12% 가량 높게 나타났다. 접착제의 두께가 얇은 0.2 mm의 경우 시험환경의 효과는 나타나지 않았다.

합성수지 메탈시트와 3면겹침용 채움재가 공법화된 합성고분자계 시트를 이용한 건식화 방수기술에 대한 실험적 연구 (Experimental Study on Dry Waterproofing Technology Using Synthetic Polymer Sheet Comprised of Synthetic Resin Metal Sheets and Tri-Layered Filler)

  • 구자응;김범수;이정훈;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2017
  • This technology employs a method of forming a single-ply PLUS waterproofing sheet layer comprised of applying a single-ply synthetic polymer layer on a vibrating structure (steel frame, RC) or an inclined surface by using a T joint lap-filling coil and an embedded metal coated sheet. The T - joint reinforcing lap-filling coil was used to block the ingress channel of the rainwater by applying the material in the vulnerable area where the three sides of the waterproof sheet overlapped. Conventional waterproofing techniques have a problem in that the waterproof sheet is pierced because the end portion of the waterproof sheet applied to the vertical portion is fixed by a nail, and the sealant applied to the end portion of the sheet cannot easily secure long-term waterproof durability due to the influence of the external environment. Therefore, the developed technology secured the waterproof durability against the vertical part by using the embedded metal sheet. In addition, automatic hot-air fusing is used to improve the quality of waterproof construction and point fixation method using fixed hardware. This is a technology that is not significantly restricted in the high degradation level regions of domestic waterproof construction environments in Korea such as low-temperature environment, wet floor.

  • PDF

가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구 (Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition)

  • 조현태;박성민;김민준;황반토;김학인;손명숙;안종기;안지민;최진호;남영우;권진회
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.275-281
    • /
    • 2020
  • 본 논문에서는 항공기 팬 블레이드에 적용되는 복합재와 금속 간의 접합 구조물에 대한 온도, 습도에 따른 접착제의 물성 변화에 관해 연구하였다. 항공기 운용 시 노출되는 환경 조건을 고려하여 상온 건조(Room Temperature Dry, RTD), 고온 흡습(Evaluated Temperature Wet, ETW), 저온 건조(Cold Temperature Dry, CTD) 세가지 환경에서 강도 시험을 수행하였다. 접착전단강도 시험은 ASTM D3528을 기준으로 수행하였고, 파손 영역에 대한 마이크로 구조 특성을 SEM이미지를 통해 분석하였다. 연구 결과에 따르면 RTD 환경에서의 전단강도 대비하여 ETW 환경에서 72.8% 저하되었으며, CTD 환경에서는 56.5% 증가되었다. 이는 고온 및 수분 흡습이 접착제의 기계적 특성에 큰 영향을 미치는 것을 확인했고, 저온 환경에서는 모재와 접착제 모두 취성의 증가로 인해 접착 전단 강도가 향상된 것으로 분석되었다.

PCS 구조 시스템 접합부의 초기 강성에 대한 연구 (Initial Stiffness of Beam Column Joints of PCS Structural Systems)

  • 박순규;김무경
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.271-282
    • /
    • 2008
  • PCS 구조 시스템은 공장 제작 콘크리트 기둥과 휨, 전단성능에 유리한 철골보를 접합한 복합구조의 일종이다. 접합부는 기둥을 관통하는 볼트를 사용하여 단부평판 접합하게 된다. 따라서 건식공법이 가능하여 작업환경이 양호하고 공기단축이 가능하며 해체가 용이한 장점이 있다. 하지만 실험을 통해 PCS 시스템의 내진성능을 분석한 결과 강도, 강성, 에너지소산 능력은 ACI 기준에 만족하였으나, 초기 강성의 경우 실험체 모두 ACI 기준에 부족하였다. 초기강성이 저하된 요인을 조사하여 접합부 강성을 증가시킬 수 있는 방안을 마련하고자 컴퓨터 시뮬레이션을 하였다. ABAQUS를 사용하여 네오프랜 패드의 유무와 두께, 단부평판과 기둥의 접촉면 형상, 볼트 긴장력의 크기, 단부평판의 강성 등과 같이 접합부 강성에 영향을 주는 변수들로 연구를 수행하였다. 그 결과 기둥과 단부평판 사이의 초기 변형이나 네오프랜과 같은 채움재와 단부평판의 낮은 강성이 초기 강성을 저하시키는 것으로 조사되었다. 접합부 성능을 개선하는 방안으로 볼트간격을 조정하거나 스티프너로 보강하여 단부평판의 강성을 높이는 방법도 효과가 있었으나, 볼트의 긴장력을 증가하는 방법이 가장 효과적이었다. 단부평판의 상하부에 분리형 네오프랜 패드를 끼워 갭의 영향을 최소화하는 방법도 꽤 우수하였다.

리기다소나무 판재(板材)의 접착조건(接着條件)이 집성재(集成材)의 접착성능(接着性能)에 미치는 영향(影響) (Effects of Adhesion Conditions on Bonding Strength of Pitch Pine Woods for Glued-Laminated Wood)

  • 박상범;공영토;조재명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권4호
    • /
    • pp.48-53
    • /
    • 1988
  • 본(本) 연구(硏究)는 리기다소나무판재(板材)를 이용(利用)하여 집성재(集成材)를 제조(製造)할 경우(境遇), 압체시간(壓締時間) 및 접착제도포량(接着劑塗布量), 목재(木材)의 함수율(含水率), Butt-joint의 틈새간격(間隔) 및 접착제(接着劑)의 종류(種類) 등(等)이 접착강도(接着强度)에 미치는 영향(影響)을 알아보기 위해 수행(遂行)되었다. 1. 리기다소나무집성재(集成材)의 제조(製造)에 수성(水性)비닐우레탄접착제(接着劑)를 사용(使用)한 결과(結果), 접착제도포량(接着劑塗布量) 200g/$m^2$, 압체압력(壓締壓力) 10kg/$cm^2$에서 12시간(時間) 압체(壓締)하면 기준강도(基準强度)(50kg/$cm^2$)이상(以上)에 달(達)하였다. 2. 판재(板材)의 함수율(含水率)의 접착력(接着力)을 크게 감소(減少)시켰으나, 고함수시(高含水時) 접착(接着)한 후(後) 기건(氣乾)하여 접착력(接着力)을 측정(測定)한 결과(結果), 100kg/$cm^2$)이상(以上)의 블록전단강도(剪斷强度)를 나타내었다. 3. 판재(板材)의 Butt joint 부분(部分)의 틈새간격(間隔)이 0.5mm이하(以下)인 경우(境遇), 강도(强度)값은 영향(影響)하지 않았고, 하중방향(荷重方向)이 접착력(接着力)과 수치(垂値)일 때가 수평(水平)일 때보다 강도성태(强度性能)이 양호(良好)하였다. 4. 시험(試驗)에 사용(使用)된 5종(種)의 접착제(接着劑) 중(中) 수성(水性)비닐우레탄수지접착제(樹脂接着劑)가 상태(常態) 및 내수접착력면(耐水接着力面)에서 가장 양호(良好)하였다.

  • PDF