• Title/Summary/Keyword: Dry air

Search Result 1,461, Processing Time 0.03 seconds

Breakdown Characteristics of Dry Air under 170[kV] GIB (170[kV] GIB 내에서 건조공기(Dry Air)의 절연파괴 특성)

  • Han, Ki-Son;Yoon, Jin-Yul;Ju, Hyung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.136-142
    • /
    • 2010
  • In this paper, we changed $SF_6$ insulation gases used already in the GIB(Gas Insulated Bus, gas insulated busbar) of switching appliances of power grid 170[kV] GIS(Gas Insulated Switchgear, Gas Insulated Switchgear) with green insulation dry air gases and studied dielectric breakdown voltage characteristics by the AC voltage withstand test. Withstand test AC voltage applied to the standard KEPCO's 170[kV] GIB with dry air insulation and and the equivalent of dry air and $SF_6$ gas were examined. Breakdown voltage of dry air, using an expression of the experiments were calculated and AC Withstand criterion of dry air insulation for the AC voltage test was derived. Using the criterion, dry air gases can be used instead of the $SF_6$ gas was confirmed in the factory acceptance test at 170[kV] GIB.

Dielectric Characteristics of SF6 and Dry-Air Gases under Lightning Impulse Voltage (뇌임펄스전압에 대한 SF6와 dry-air의 절연특성)

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.142-149
    • /
    • 2010
  • This paper describes dielectric characteristics of $SF_6$ and dry-air gases under lightning impulse voltages in a quasi-uniform electric field. In order to simulate to a quasi-uniform electric field, electric field utilization factor of the used sphere-plane electrode is 71[%]. The gas pressure of $SF_6$ ranges from 0.1 to 0.2[MPa] and that of dry-air ranges from 0.2 to 0.6[MPa]. Electrical breakdown voltages of $SF_6$ and dry-air gases are measured and analyzed as functions of the polarity of lightning impulse voltage and gas pressure. As a result, the electrical breakdown voltage of both gases under the positive lightning impulse voltage is higher than that under the negative one. The electrical breakdown voltage in $SF_6$ is almost higher than 2.67 times compared to dry-air. The results presented in this paper can be used as a useful information to evaluate the capability of alternative insulation gases for $SF_6$ in power distribution equipment with prominent ability against lightning surge.

A Study on Dielectric Strength and Insulation Property of High Voltage Switchgear Applied Dry Air Gas (Dry Air Gas를 적용한 초고압 Switchgear 절연특성연구)

  • Jeong, D.H.;Chung, Y.H.;Seo, K.B.;Kim, T.H.;Kim, J.B.;Lee, H.S.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1731-1737
    • /
    • 2008
  • This paper present the fundamental insulation characteristics of Dry Air gas and insulation coating in high voltage power apparatus. It is known that the dielectric strength. of Dry Air is approximately one-third that of SF6 gas. we attempt that the insulation coating and dry air gas have replaced the SF6 gas as insulation of the switchgear. We proposed the dry air insulated switchgear(DAIS) for High Voltage apparatus. To acquire technology of insulation characteristic improvement made standards for complex insulation structure and conducted simulations and experiments

The Breakdown Characteristics for Dry-Air with Humidity Variations (Dry-Air의 습도에 따른 절연파괴 특성)

  • Park, He-Rie;Kim, Young-Su;Choi, Eun-Hyuck;Park, Kwang-Seo;Kim, Lee-Kook;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.238-240
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of Dry-Air and air based on their dew point and humidity variations in experimental GIS model by applying AC voltage. The breakdown voltage of Dry-Air was increased as gap length had been increased. The characteristics of Dry-air which had low dew point were higher. In the case of air, the breakdown voltage curves were like Dry-Air' s. But the curves were slightly folded up and down because of impurities.

  • PDF

A Case Study for Installation of Dry Washing Process in Kitchen (주방에서 건식 식기 세척기 설치 및 운전 사례연구)

  • Tateda, Masafumi;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.391-396
    • /
    • 2007
  • Dry washing by air and sand to clean dishes was investigated for establishing a dry washing process in a kitchen. Thirty seasonings and foods as dirt markers and fourteen kinds of dishes were used for the experiment, and washing efficiency was evaluated by COD-MN (mg/L). It was found that air dry washing effectively reduced COD-MN of some dirt markers but not effective at all to some dirt markers. It could be also said that dirt markers would not be completely removed by air dry washing. The shape of dishes also affected COD-MN reduction by air dry washing. Sand dry washing showed excellent efficiency on COD-MN reduction. Combination of air and sand dry washing may be necessary to make a dish dry washing system which is completely independent from water.

Breakdown Characteristics of Dry Air under 362 kV GIB (362 kV GIB 내에서 건조공기의 절연파괴 특성)

  • Han, Ki-Son;Ju, Hyung-Jun;Yoon, Jin-Yul;You, Hong-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Breakdown Characteristics of Mixtures of $SF_6$ and Dry air under Uniform and Nonuniform Electric Field ($SF_6$와 Dry air가 혼합된 가스의 평등/불평등 전계에 의한 절연파괴특성 연구)

  • Lee, Sang-Hwa;Jung, Hyun-Jae;Jeong, Seung-Young;Ryu, Cheol-Hwi;Bang, Hang-Kwon;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1502-1504
    • /
    • 2006
  • 본 연구는 $SF_6$와 Dry-air(건조공기)가 혼합된 절연매체의 절연 특성과 부분방전 특성 연구를 위하여 기초실험용 쳄버와 70kV급 GIS mock up 을 이용하여 교류전압을 인가하여 실험이 수행되었다. 전자의 경우, Sphere gap 및 Needle/Plate 전극시스템을 이용하여 순수 $SF_6$가스와 Dry-air의 절연내력을 비교하고, 챔버의 압력을 5기압으로 유지한 상태에서 Dry-air와 $SF_6$가스의 혼합비를 변화시키면서 절연내력이 측정되었다. 후자의 경우, 기초실험에서 도출된 $SF_6$가스와 Dry-air의 최적의 혼합비율을 선택한 후, 방전 개시전압과 부분방전 양상을 순수 $SF_6$가스의 결과와 비교 분석하기 위한 실험을 수행하였다. 이를 위하여 GIS 사고의 주요원인이 되는 결함들, 즉 Protrusion, Floating, Free moving particle 들을 인위적으로 모의하여 Mock up 내부에 설치하고 내부 압력을 5기압으로 유지한 상태에서 수행되었다. 전자의 경우, $0.5{\sim}5$ 기압 범위내 에서 Dry-air 압력을 변화시켰을 때 절연내력은 전극시스템에 무관하게 순수 $SF_6$가스의 결과치의 $40{\sim}50%$정도이다. 또한 챔버 압력이 5기압일 경우, Needle/Plate 전극을 이용했을 경우, Dry-air 가 80% 혼합된 절연매체는 순수 $SF_6$가스 절연내력의 80%정도이다. 후자의 경우, 인가전압을 고정 시켰을 때, 부분방전 패턴과 방전크기는, 순수 $SF_6$가스와 Dry-air 가 80% 혼합된 절연매체는 동일한 패턴과 방전크기를 나타내고 있다. 이러한 결과를 근거로, 가스 압력이 5기압에서 운전되는 전력기기의 절연 매체로서 혼합가스를 사용할 경우, $SF_6$가스와 Dry-air의 혼합비는 2:8정도가 적절한 것으로 제안한다.

  • PDF

A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger (건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구)

  • 김병조;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.