A Comparison of Butorphanol and Fentanyl Administered in Conjunction with Ketorojac in Intravenous Patient Controlled Analgesia after Total Abdominal Hysterectomy (복식 전자궁 절제술 후 통증 자가 조절 장치를 통하여 Ketorolac과 함께 투여한 Butorphanol과 Fentanyl의 비교)

  • Kim, Dong-Hee;Min, Hye-Ra
    • The Korean Journal of Pain
    • /
    • v.11 no.1
    • /
    • pp.60-64
    • /
    • 1998
  • Background: We compared butorphanol and fentanyl for opioids use in patient-controlled analgesia(PCA) with ketorolac to determine a suitable drug combination for postoperative pain control. Methods: Sixty patients were equally divided into 2 Groups. Group 1 (n=30) butorphanol 10 mg with ketorolac 180 mg; Group 2 (n=30) fentanyl 1 mg with ketorolac 180 mg, diluting 100 ml solutions intravenously via PCA pump after total abdominal hysterectomy under general anesthesia. Total infusion dosage of PCA drug, VAS pain scores, and side effects of both group were manitored. Results: Total infusion dosages were as follows: (Group 1) butorphanol 8.3 mg with ketorolac 149.7 mg; (Group 2) fentanyl $646.6\;{\mu}g$ with ketorolac 116.2 mg. The two groups showed similar pain scores auld side effects. Conclusions : Both butorphanol and fentanyl were effective for postoperative pain control using PCA pump, but butorphanol was more economical. The putative potency ratio of butorphanol to fantanyl was 12.8 : 1.

  • PDF

Studies on Osmotically Driven Drug Infusion Pump Under the Change in Body-Simulating Environment (인체 내부 환경 변화 모사에 따른 삼투압 기반 약물주입펌프의 기능 평가 연구)

  • Yoon, Chul Whan;Ahn, Jae Hong;Park, Doh;Lee, Jae Yeon;Park, Chun Gwon;Park, Min;Choy, Young Bin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.291-295
    • /
    • 2015
  • Various types of implantable drug delivery devices have attracted significant attention for several decades to improve drug bioavailability and reduce side effects, thus enhancing therapeutic efficacy and patients' compliance. However, when implanted into the body, the devices may be influenced by the changes in physiological condition, such as temperature, pH or ionic concentration. Thus, the drug release rates could be also altered concurrently. Therefore, in this work, we employed an implantable ALZET$^{(R)}$ Osmotic Pump, which has been widely used to locally deliver various therapeutic agents and examined the effect of pH, temperature and ionic concentration on its drug release rate. For this, we performed in vitro cell tests to simulate the condition of local tissues influenced by the altered drug release rates, where we used diclofenac sodium as a model drug.

Catheter Obstruction of Intrathecal Drug Administration System -A Case Report-

  • Rhee, Seok-Myeon;Choi, Eun-Joo;Lee, Pyung-Bok;Nahm, Francis Sahn-Gun
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.47-51
    • /
    • 2012
  • Intrathecal drug administration system (ITDAS) can reduce the side effects while increasing the effectiveness of opioids compared to systemic opioid administration. Therefore, the use of ITDAS has increased in the management of cancer pain and chronic intractable pain. Catheter obstruction is a serious complication of ITDAS. Here, we present a case of catheter obstruction by a mass formed at the side hole and in the lumen. A 37-year-old man suffering from failed back surgery syndrome received an ITDAS implantation, and the ITDAS was refilled with morphine every 3 months. When the patient visited the hospital 18 months after ITDAS implantation for a refill, the amount of delivered morphine sulfate was much less than expected. Movement of the pump rotor was examined with fluoroscopy; however, it was normal. CSF aspiration through the catheter access port was impossible. When the intrathecal catheter was removed, we observed that the side hole and lumen of the catheter was plugged.

Development of Target-Controlled Infusion System in Plasma Concentration. PART1 : Establishment of Pharmacokinetic Model and Verification (혈중 목표 농도 자동 조절기(TCI) 개발 PART1 : 약동학적 모델의 수립과 검증)

  • 안재목;길호영
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.341-349
    • /
    • 2002
  • The target controlled infusion(TCI) pump system is a logical approach to the development of improved administration techniques of an intravenous anaesthetic agent. The principle of TCI system is based on an understanding of the pharmacokinetic properties, three or four compartment model. The TCI system is optimal and flexible control of the plasma drug concentration. But the clinical goal is always to achieve a therapeutic drug effect, not a therapeutic concentration. So we developed the algorithm to target the concentration at the site of drug effect rather than the concentration in the plasma. If impulse drug is inputted into body, the decline of plasma concentration with time is shown, resulting in the expression of the differential equation. Therefore, we must reformulate our three-compartment model as four-compartment model with the effect compartment. And we tested plasma targeting and effect targeting algorithm by computer simulation using four-compartment model. So we developed the TCI capable of applying all intravenous drugs by adjusting individual pharmacokinetic parameters independently.

Implantation of an Intrathecal Drug Administration System -A report of two cases- (척수강 내 약물 주입기의 이식 -증례보고-)

  • Lee, Sang Jin;Nam, Sang Kun;Kim, Jang Hyun;Kim, Hyun Joo;Lee, Sang Chul;Kim, Yong Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.68-73
    • /
    • 2009
  • Opioids profoundly inhibit evoked discharges of spinal nociceptive neurons, thereby inhibiting the transmission of pain. Intrathecal administration of opioids using implantable continuous infusion systems is an effective method of pain relief when other treatments have failed, as well as for patients with adequate analgesia on high dose therapy that produces unacceptable side effects. We report two cases of intrathecal pump implantation performed in patients suffering from intractable chronic pain. A test dose of 3 mg morphine was injected into the epidural space. No side effects were noted and patients experienced considerable pain relief. Implantation was performed one day after the test. The initial intrathecal morphine delivery dose was half of the equivalent dose of daily oral intake opioids and the infusion rate was increased gradually under close observation for opioid side effects. Two days post-implantation, both patients were discharged without any complications.

The Long-Term Safety and Efficacy of Intrathecal Therapy Using Sufentanil in Chronic Intractable Non-Malignant Pain

  • Monsivais, Jose Jesus;Monsivais, Diane Burn
    • The Korean Journal of Pain
    • /
    • v.27 no.3
    • /
    • pp.297-300
    • /
    • 2014
  • This report describes the long term safety and efficacy of intrathecal therapy using Sufentanil for the management of chronic intractable neuropathic pain in 12 chronic pain patients. Standardized psychological screening was used to determine treatment suitability. Evaluation data included the Visual Analog Scale (VAS), Wong-Baker Faces Scale, Brief Pain Inventory (BPI), Disability of Arm, Shoulder, and Hand (DASH), McGill Quality of Life Questionnaire, and complications (granulomas, toxicity, withdrawal, or deaths). SPSS version 18 was used for data analysis. Pre- and post- treatment BPI measures and pain scale scores showed a statistically significant difference. There were no complications directly related to drug toxicity, nor drug withdrawals, granulomas, or deaths. Intrathecal therapy with Sufentanil therapy offers a good treatment alternative for those cases that have failed both surgery and standard pain treatment. Strict patient selection based on psychological screening, control of co-morbidities, a proper pain management may contribute to successful outcome.

The evaluation of implementing smart patient controlled analgesic pump with a different infusion rate for different time duration on postoperative pain management

  • Kim, Saeyoung;Jeon, Younghoon;Lee, Hyeonjun;Lim, Jung A;Park, Sungsik;Kim, Si Oh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.4
    • /
    • pp.289-294
    • /
    • 2016
  • Background: Control of postoperative pain is an important aspect of postoperative patient management. Among the methods of postoperative pain control, patient-controlled analgesia (PCA) has been the most commonly used. This study tested the convenience and safety of a PCA method in which the dose adjusted according to time. Methods: This study included 100 patients who had previously undergone orthognathic surgery, discectomy, or total hip arthroplasty, and wished to control their postoperative pain through PCA. In the test group (n = 50), the rate of infusion was changed over time, while in the control group (n = 50), drugs were administered at a fixed rate. Patients' pain scores on the visual analogue scale, number of rescue analgesic infusions, side effects, and patients' satisfaction with analgesia were compared between the two groups. Results: The patients and controls were matched for age, gender, height, weight, and body mass index. No significant difference in the mount of drug administered was found between the test and control groups at 0-24 h after the operation; however, a significant difference was observed at 24-48 h after the operation between the two groups. No difference was found in the postoperative pain score, number of side effects, and patient satisfaction between the two groups. Conclusions: Patient-controlled anesthesia administered at changing rates of infusion has similar numbers of side effects as infusion performed at a fixed rate; however, the former allows for efficient and safe management of postoperative pain even in small doses.

Comparison of Anesthesiologist Controlled Sedation and Patient Controlled Sedation during Neurolytic Pain Block and Regional Anesthesia (통증치료를 위한 신경차단과 부위 마취시 Anesthesiologist Controlled Sedation과 Patient Controlled Sedation의 비교)

  • Kim, Ik-Gon
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.199-204
    • /
    • 1994
  • The purpose of this study is to evaluate the feasibility, advantages/disadvantages of patient-controlled sedation (PCS) compared to anesthesiologist-controlled sedation (ACS) during neurolytic pain block and regional anesthesia. Forty patients were divided randomly into two groups of 20 patients each. Group 1(ACS) received 0.01 $mg{\cdot}kg^{-1}$ intravenous midazolam and 0.5 ${\mu}g{\cdot}kg^{-1}$ fentanyl intravenously by anesthesiologist just before, 30, and 60 minutes after the procedure to acheive sedation; Group 2 (PCS) patients self-administered a mixture of midazolam (0.4 mg) and fentanyl ($20{\mu}g$) using a syringe type infusion pump (Terumo, Japan) to acheive sedation. Considering the dermographics of patients, the types and durations of procedure performed, the level of average sedation the comfort level were similar in both groups. But the doses of midazolam and fentanyl administerd in group 2 were smaller than those in group 1 (p<0.01). Patients in PCS group showed their level of sedation more proper than did those in ACS group. However, patients in ACS group rated their level of comfort higher than did those in PCS group. The findings of this study indicate that PCS using a combination of midazolam and fentanyl is a fafe and effective technique. More studies are, however, needed to determinc the best choice of drug(s), doses, lock-out intervals, and possible use of continuous infusion with patient-controlled sedation.

  • PDF

Comparison of the effects of target-controlled infusion-remifentanil/midazolam and manual fentanyl/midazolam administration on patient parameters in dental procedures

  • Lobb, Doug;Ameli, Nazila;Ortiz, Silvia;Lai, Hollis
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.117-128
    • /
    • 2022
  • Background: Moderate sedation is an integral part of dental care delivery. Target-controlled infusion (TCI) has the potential to improve patient safety and outcome. We compared the effects of using TCI to administer remifentanil/manual bolus midazolam with manual bolus fentanyl/midazolam administration on patient safety parameters, drug administration times, and patient recovery times. Methods: In this retrospective chart review, records of patients who underwent moderate intravenous sedation over 12 months in a private dental clinic were assessed. Patient indicators (pre-, intra-, and post-procedure noninvasive systolic and diastolic blood pressure, respiration, and heart rate) were compared using independent t-test analysis. Patient recovery time, procedure length, and midazolam dosage required were also compared between the two groups. Results: Eighty-five patient charts were included in the final analysis: 47 received TCI-remifentanil/midazolam sedation, and 38 received manual fentanyl/midazolam sedation. Among the physiological parameters, diastolic blood pressure showed slightly higher changes in the fentanyl group (P = 0.049), respiratory rate changes showed higher changes in the fentanyl group (P = 0.032), and the average EtCO2 was slightly higher in the remifentanil group (P = 0.041). There was no significant difference in the minimum SpO2 levels and average procedure length between the fentanyl and remifentanil TCI pump groups (P > 0.05). However, a significant difference was observed in the time required for discharge from the chair (P = 0.048), indicating that patients who received remifentanil required less time for discharge from the chair than those who received fentanyl. The dosage of midazolam used in the fentanyl group was 0.487 mg more than that in the remifentanil group; however, the difference was not significant (P > 0.05). Conclusion: The combination of TCI administered remifentanil combined with manual administered midazolam has the potential to shorten the recovery time and reduce respiration rate changes when compared to manual administration of fentanyl/midazolam. This is possibly due to either the lower midazolam dosage required with TCI remifentanil administration or achieving a stable, steady-state low dose remifentanil concentration for the duration of the procedure.

A Study on the test method of conformity characteristics of u-Healthcare drug infusion pump (유헬스케어 의약품주입펌프의 적합성 평가기술 연구)

  • Jeon, So-Hye;Park, Su-Kang
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1433-1434
    • /
    • 2015
  • 의료기기 무선통신 기능을 포함한 유헬스케어형 기기들이 지속적으로 개발됨에 따라 전기 및 기계적 안전에 관한 공통기준규격 IEC 60601-1(3rd)과 개별규격에 더불어 추가적인 안전성 시험 항목이 요구되고 있다. 유헬스케어형 의약품주입펌프의 적합성을 평가하기 위하여 IEC60601-1-11와 IEC60601-2-24 규격을 기반으로 하여 부품 및 분류방법, 필수성능에 대한 시험항목을 도출하였다. 본 연구에서는 국제규격에 기반하여 적합성 평가기술을 개발하여 헬스케어형 의료기기의 안전성 확보와 선도적 평가기술 방안을 마련하였다.

  • PDF