• 제목/요약/키워드: Drop-Out

Search Result 1,049, Processing Time 0.024 seconds

A study on Extraction of Zinc in the Aqueous Water by D2EHPA (D2EHPA에 의한 수용액속의 아연 추출에 관한 연구)

  • Lee, Su Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.2 no.1
    • /
    • pp.17-29
    • /
    • 1987
  • The extraction mechanism of Zinc from aqueous solution with D2EHPA (Di-2-Ethylhexyl Phosphoric Acid) dissolved in Kerosene was studied by the single drop method. The effect of the concentrations of reactant species on the extraction rate, Zinc and hydrogen ion in the continuous phase and D2EHPA in the dispersed, was studied for the drop rise period by the experiment. Then a theoretical analysis on the basis of Handlos-Baron modle was carried out. It becomes clear that the extraction rate was controlled by the neutral complex forming reaction at the drop surface from both analysises. From effect of the concentrations of species on the reaction rate, the extraction rate at the drop surface is considered to be as follows. $${\gamma}_{pn}=9.42{\times}10^{-7}\;\frac{[Zn^{2+}][(HR)_2]^{3/2}}{[H^+]^{3/2}}$$

  • PDF

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Analysis of Package Drop and its Application for Optical Disc Drives (광 디스크 드라이브용 완충포장재의 낙하충격 해석 및 활용)

  • 석기영;윤기원;나정민;박창배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.177-182
    • /
    • 2004
  • Electronic products are subjected to many different types of shock environment. As the Optical Disc Drive (ODD) market grows, the number of failures related to shock increases. Therefore, it is necessary to improve the performance of cushion package as well as the product design. Cushion materials such as expanded polystyrene are often used to protect electronic products from shock environment. In this paper, the drop analysis of the cushion package f3r optical disc drives was carried out with the explicit method of LS-DYNA and verified by the drop test. For the optimization of package, response surface approximation model was created using central composite design. As a result, cushioning performance was improved under the critical condition and practical design guidelines of cushion package were suggested.

  • PDF

Design for Improving Impact Resistance of Microwave Oven Using Drop/Impact Analysis (낙하/충격해석을 통한 전자렌지의 내충격설계)

  • Kim, J.G.;Kim, J.Y.;Kim, H.S
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.53-58
    • /
    • 2009
  • The importance of cost reduction has grown bigger to ensure the competetive power of products in the electric home appliances industry. Thus, it is necessary to assess the reliability due to drop-impact happenning in process of distribution of microwave ovens with the panel and cavity of thinner thickness for cost reduction. In the present study, the drop/impact simulation using the explicit code LS-DYNA3D has been carried out for improving the impact resistance of a microwave oven. This CAE-based design approach can be successfully applied to enhance the deteriorated dynamic behavior under the impact conditions of dropping height 70cm according to ISTA procedure 2A.

  • PDF

Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet (상부유입식 전기 Cyclone-Bag Filter의 특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF

Fabrication of MEMS Inkjet Head for Drop-on-Demand Ejection of Electrostatic Force Method (정전기력 방식의 Drop-on-Demand 토출을 위한 MEMS 잉크젯헤드 제작)

  • Son, S.U.;Kim, Y.M.;Choi, J.Y.;Ko, H.S.;Kim, Y.J.;Byun, D.Y.;Lee, S.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1441-1444
    • /
    • 2007
  • This paper presents a novel electrostatic drop-an-demand ejector with a conductive pole inside nozzle. The MEMS fabricated pole-type nozzle shows a significant improvement in the performance and reliability of forming meniscus and generating a micro dripping mode of droplet out of the meniscus. It is verified experimentally that the use of the pole-type nozzle. The liquid is used D20+SDS+SWNT (5 %wt). The gap between upper electrode and nozzle is about 600 um. Electrostatic drop-an-demand ejection is observed when a DC voltage of 1.5 kV is applied between the control electrode and ground electrode. Droplet diameter is $100{\mu}m$.

Analysis Method on the Free Drop Impact Condition of Spent Nuclear Fuel Shipping Casks (자유낙하충격조건에 있는 사용후핵연료 운반용기의 충격해석방법 연구)

  • 이재형;이영신;류충현;나재연
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.766-771
    • /
    • 2001
  • The package used to transport radioactive materials, which is called by cask, must be safe under normal and hypothetical accident conditions. These requirements for the cask design must be verified through test or finite element analysis. Since the cost for FE analysis is less than one for test. the verification by FE analysis is mainly used. But due to the complexity of mechanical behaviors. the results depends on how users apply the codes and it can cause severe errors during analysis. In this paper, finite element analysis is carried out for the 9 meters free drop and the puncture condition of the hypothetical accident conditions using LS-DYNA3D and ABAQUS/Explicit. We have investigated the analyzing technique for the free drop impact test of the cask and found several vulnerable cases to errors. The analyzed results were compared with each other. We have suggested a reliable and relatively simple analysis technique for the drop test of spent nuclear fuel casks.

  • PDF

Performance Test and Evaluation of Ship Exhaust Muffler (선박용 소음기 성능 시험 및 평가)

  • Kim, Bong-Ki;Kim, Sang-Ryul;Kim, Hyun-Sil;Shin, Min-Chol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1237-1242
    • /
    • 2008
  • A muffler design in the exhaust system is critical to provide fur low noise in shipboard spaces. In an attempt to effectively design the low noise muffler, it Is important to evaluate the performance of the muffler considering not only the noise, but also pressure drop as well. For this purpose, a test system of large exhaust mufflers fur ship propulsion systems was designed based on ISO 7235. The substitution test fur determining both the insertion loss and pressure drop of mufflers was carried out. A ship exhaust muffler is considered as a test example and the insertion loss and pressure drop were obtained.

Wet Drop Impact Response Analysis of CCS in Membrane Type LNG Carriers -II : Consideration of Effects on Impact Response Behaviors- (멤브레인형 LNG선 화물창 단열시스템의 수면낙하 내충격 응답해석 -II : 내충격 응답거동에 미치는 영향 고찰-)

  • Lee, Sang-Gab;Hwang, Jeong-Oh;Kim, Wha-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.735-749
    • /
    • 2008
  • For the development of the original technique of structural safety assessment of Cargo Containment System(CCS) in membrane type LNG carriers, it is necessary to understand the characteristics of dynamic response behavior of CCS structure under sloshing impact pressure. In the previous study, the wet drop impact response analyses of CCS structure in membrane Mark III type LNG carriers were carried out by using Fluid-Structure Interaction(FSI) analysis technique of LS-DYNA code, and were also validated through a series of wet drop experiments for the enhancement of more accurate shock response analysis technique. In this study, the characteristics of structural shock response behaviors of CCS structure were sufficiently figured out by careful examinations of the effects of specimen weight, drop height, incident angle, corrugation and stiffness of inner hull on its shock response behaviors. The shock response analysis of upward shooting fluid to inner hull was performed, and the reason of faster strain response than shock pressure one was also figured out.

The Effects of the Band Type Foot Drop Device (밴드형 첨족예방기구의 효과와 유용성)

  • Kang Hyun-Sook;Kim Won-Ock;Lee Hya-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF