• 제목/요약/키워드: Drop performance test

검색결과 302건 처리시간 0.023초

균형훈련과 환경강화가 외상성 소뇌 손상 흰쥐의 운동 수행력에 미치는 영향 (The Effect of Balance Training and environmental enrichment on motor performance after Traumatic Cerebellar Injury in the Rat)

  • 송주민;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.72-89
    • /
    • 2004
  • The purposes of this study were to test the effect of balance training and environmental enrichment on motor performance after traumatic cerebellar injury in the rat. Traumatic cerebellar injury was induced by weight drop model and after operation they were housed in individual standard cages for 24 hours. Twenty two Sprague-Dawley rats were randomly assigned into control and experimental groups. The control group was housed in standard cage for 7 days. The experimental group I was housed in standard cage after balance training for 7 days. The experimental group II was housed in environmental enrichment cage after balance training for 7 days. Vestibular drop test and tilting plane test was examined at preoperation, on 1st day after operation and 7th day after operation to the rats. The results of this experiment were as follows: 1. In motor behavioral test, at preoperation and on 1 day after operation, the outcomes were not different among the groups. But on 7th day after operation, the outcomes of group I were better than that in control group, and group II were better than group I. These results suggest that behavioral motor outcome by simultaneously application of balance training and environmental enrichment in traumatic cerebellar injured rats were more improve than that by just balance training.

  • PDF

다순환 여과시험에 의한 자동차용 연료필터의 성능 평가 (Performance Evaluation of an Automotive Fuel Filter by Multi-Pass Filtration Test)

  • 이재천;장지현
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.219-226
    • /
    • 2002
  • Filtration performance of an automotive fuel filter was evaluated based on the theory of Beta ratio. This study also introduced the fuel components' contamination performance test stand incorporating the multi-pass filtration test circuit. The theoretical basis of multi-pass test and test procedure were described in detail. The specification of commercial fuel filter currently available was just the maximum pressure drop across the filter assembly and the holding capacity of contaminants. However, test results revealed that the fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity close to the specification. Hence the Beta ratio should be specified in service life. The results also showed that filtration system model should be refined including desorption ratio to estimate the variable Beta ratio in the test.

Computer Simulation of an Automotive Air-Conditioning in a Transient Mode

  • Oh, Sang-Han;Won, Sung-Pil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.220-228
    • /
    • 2002
  • The cool-down performance after soaking is very important in an automotive air-conditioning system and is considered as a key design variable. Therefore, transient characteristics of each system component are essential to the preliminary design as well as steady-state performance. The objective of this study is to develop a computer simulation model and ostinato theoretically the transient performance of an automotive air-conditioning system. To do that, the mathematical modelling of each component, such as compressor, condenser, receiver/drier, expansion valve, and evaporator, is presented first of all. The basic balance equations about mass and energy are used in modelling. For detailed calculation, condenser and evaporator are divided into many sub-sections. Each sub-section is an elemental volume for modelling. In models of expansion valve and compressor, dynamic behaviors are not considered in this analysis, but the quasisteady state ones are just considered, such as the relation between mass flow rate and pressure drop in expansion device, polytropic process in compressor, etc. Also it is assumed that there are no heat loss and no pressure drop in discharge, liquid, and suction lines. The developed simulation model is validated by comparing with the laboratory test data of an automotive air-conditioning system. The overall time-tracing properties of each component agreed well with those of test data in this case.

착륙장치 내추락 설계 및 시험평가 (Crashworthy Design and Test of Landing Gear)

  • 김태욱;이상욱;신정우;이승규;김성찬;황인희;조정준;이제동
    • 한국항공우주학회지
    • /
    • 제40권7호
    • /
    • pp.601-607
    • /
    • 2012
  • 착륙장치는 완충장치를 이용하여 항공기 착륙 시의 충격을 흡수하는 역할을 한다. 군용 헬기를 비롯한 일부 항공기에서는 비상 착륙시 탑승원의 생존성과 안전성을 향상시키기 위해, 착륙장치에 내추락 요구조건을 부여하기도 한다. 이 논문에서는 관련 규정에서 요구하고 있는 내추락 요구조건을 충족하는 착륙장치 설계 개념을 제시하고, 성능해석 및 낙하시험을 통한 입증 과정을 소개한다. 추락 시 착륙장치 충격흡수 능력과 거동은 낙하시험 시 측정한 다양한 센서 데이터 및 고속 카메라로 촬영한 동영상 분석을 통해 확인할 수 있다.

1MVA 초전도 변압기 전류 통전 시험 (Transportation Current Test for 1 MVA HTS Transformer)

  • 박정호;송희석;김우석;김성훈;이동근;최경달
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.41-44
    • /
    • 2003
  • We manufactured double pancake type windings with BSCCO wire for 1MVA HTS transformer. To verify cracks of HTS wire and performance of manufactured windings, the transportation current was measured. In this paper, we present result of the transportation current test as a DC current and compare a drop of current performance of HTS wire due to tension and rounding during the manufacturing with technical data. We obtained good results and this will be useful for another manufacturing of HTS winding

  • PDF

Modeling and Analysis of Cushioning Performance for Multi-layered Corrugated Structures

  • Park, Jong Min;Kim, Ghi Seok;Kwon, Soon Hong;Chung, Sung Won;Kwon, Soon Goo;Choi, Won Sik;Kim, Jong Soon
    • Journal of Biosystems Engineering
    • /
    • 제41권3호
    • /
    • pp.221-231
    • /
    • 2016
  • Purpose: The objective of this study was to develop cushion curves models and analyze the cushioning performance of multi-layered corrugated structures (MLCS) using a method based on dynamic stress-energy relationship. Methods: Cushion tests were performed for developing cushion curve models under 12 combinations of test conditions: three different combinations of drop height, material thickness, and static stress for each of four levels of energy densities between 15 and $60kJ/m^3$. Results: Dynamic stress and energy density for MLCS followed an exponential relationship. Cushion curve models were developed as a function of drop height, material thickness, and static stress for different paperboards and flute types. Generally, the differences between the shock pulse (transmitted peak acceleration) and cushion curve (position and width of belly portion) for the first drop and the averaged second to fifth drop were greater than those for polymer-based cushioning materials. Accordingly, the loss of cushioning performance of MLCS was estimated to be greater than that of polymer-based cushioning materials with the increasing number of drops. The position of the belly of the cushion curve of MLCS tends to shift upward to the left with increasing drop height, and the belly portion became narrower. However, depending on material thickness, under identical conditions, the cushion curve of MLCS showed an opposite tendency. Conclusions: The results of this study can be useful for environment-friendly and optimal packaging design as shock and vibrations are the key factors in cushioning packaging design.

운전조건 변화에 따른 루버휜 열교환기 성능변화에 관한 실험적 연구 (An Experimental Study on the Performance of the Louver Fin Type Heat Exchanger by the Change of the Driving Condition)

  • 김정국;소산번;상원헌;김동휘;박병덕
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.440-445
    • /
    • 2008
  • The present study was investigated the effect of the driving condition on the performance of a louver fin and tube type heat exchanger under frosting condition. Heat transfer rate and pressure drop by frost were experimentally investigated. Effects of the wet blub temperature and the shape of a fin on heat transfer performances has been also investigated. The key parameters were fin type(louver and corrugate fin) and the wet blub temperature of air (0.5, 1.0, $1.5^{\circ}C$). The heat transfer performance of the louver fin and tube type heat exchanger was higher by 0.89% than the corrugate fin type. As the wet blub temperature of air were increased, the heat transfer rate, pressure drop and mass of frost of three test models(Type A, B, C) were increased. Especially, the maximum heat transfer rate and maximum pressure drop were shown for the louver fin and tube type heat exchanger. As a experimental result, the enhancement factor(EF) of louver fin and tube type heat exchanger was $0.2{\sim}0.4$ due to the high pressure drop.

  • PDF

원위치 동적강성 분석기의 개발 및 성능평가 (Development and Performance Evaluation of In-situ Dynamic Stiffness Analyzer)

  • 김동주;변용훈
    • 한국농공학회논문집
    • /
    • 제61권2호
    • /
    • pp.41-50
    • /
    • 2019
  • Stiffness characteristic of subgrade is one of the most important aspects for the design and evaluation of pavement and railway. However, adequate field testing methods for evaluating the stiffness characteristics of the subgrade have not been developed yet. In this study, an in-situ dynamic stiffness analyzer (IDSA) is developed to evaluate the characteristics of subgrade stiffness along the depth, and its performance is evaluated in elastic materials and a compacted soil. The IDSA consists of a falling hammer system, a connecting rod, and a tip module. Four strain gauges and an accelerometer are installed at the tip of the rod to analyze the dynamic response of the tip generated by the drop of hammer. Based on the Boussinesq's method, the stiffness and Young's modulus of the specimens can be calculated. The performance of IDSA was tested on three elastic materials with different hardness and a compacted soil. For the repeatability of test performance, the dynamic signals for force and displacement of the tip are averaged from the hammer impact tests performed five times at the same drop height. The experimental results show that the peak force, peak displacement, and the duration depend on the hardness of the elastic materials. After calculating the stiffness and elastic modulus, it is revealed that as the drop height of hammer increases, the stiffness and elastic moduli of MC nylon and the compacted soil rapidly increase, while those of urethanes less increase.

친환경 접촉점화 추진제 점화 성능 평가 (Evaluation of Ignition Performance of Green Hypergolic Propellant)

  • 김선진;신민규;차정열;고영성
    • 항공우주시스템공학회지
    • /
    • 제17권1호
    • /
    • pp.51-58
    • /
    • 2023
  • 별도의 점화원 없이 스스로 점화가 가능한 접촉점화 추진제는 부식성과 독성으로 인하여 취급의 어려움이 있다. 따라서 독성이 적거나 없는 친환경 접촉점화 추진제의 개발이 필요하며, 본 연구에는 친환경 접촉점화 추진제의 기초 연구를 수행하였다. 산화제로 95%의 과산화수소, 연료로 CNU_HGFv1를 사용하였으며 액적 낙하 시험, 점화 시험 및 연소 시험을 통하여 추진제의 점화 및 연소 특성을 확인하였다. 액적 낙하 시험 결과 점화지연 시간은 9.7ms 이며, 점화시험에서는 약 27ms로 추진제로 사용하기에 충분히 빠른 것을 확인하였다. 연소시험 결과 약 11.7bar에서 연소 효율 95.4~98.1%를 달성하였으며, 하드스타트 및 연소 불안정 없이 빠르고 안정적인 연소가 가능함을 확인하였다.

연구용 원자로 내부에 설치되는 이차정지구동장치의 내진낙하성능 (Seismic Drop Performance for Second Shutdown Drive Mechanism Installed in Research Reactor)

  • 김상헌;김경호;선종오;조영갑;김정현;정택형;이관희
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.697-704
    • /
    • 2016
  • The second shutdown drive mechanism (SSDM) that is classified into seismic category I as an active mechanical equipment shall maintain the structural integrity and its designed inherent safety functions during and/or after normal operation, anticipated operational occurrences, accidents and seismic occurrences. Therefore, not only a structural integrity assessment through numerical analyses but also a qualification test by using the prototype SSDM shall be conducted to verify the adequacy of the SSDM design. This paper describes a sort of seismic qualification test of the prototype SSDM to demonstrate that the structural integrity and operability (functionality) of SSDM are maintained during and/or after seismic excitations. From the results, this paper shows that the SSDM satisfies all design requirements without any malfunctions during and after the seismic test.