• Title/Summary/Keyword: Drop out

Search Result 1,049, Processing Time 0.033 seconds

Case Series of Patients with Parkinson Syndrome visited in Oriental Medicine Hospital (한방병원에 내원한 파킨슨 증후군 환자 증례군 보고)

  • Lee, Seung-yeop;Kim, Mi-young;Kim, Young-jee;Choi, Won-woo;Min, In-kyu;Sun, Jong-joo;Hong, Jin-woo;Na, Byong-jo;Jung, Woo-sang;Moon, Sang-kwan;Cho, Ki-ho;Kim, Young-suk
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.8 no.1
    • /
    • pp.34-39
    • /
    • 2007
  • Objective : To report cases of patients with Parkinson's syndrome. Design : Case-series Patients and methods : 35 of patients with Parkinson's syndrome who visited Department of Cardiovascular and Neurologic Diseases of Kyunghee Oriental Medical Center were treated by acupuncture and herbal medicine from May until December 2007. 35 patients were participated in this study. 21 patients were dropped out during the trial, and we evaluated symptom progress of 14 patients by using several questionnaires such as Unified Parkinson's Disease Rating Scale(UPDRS), modified Hoehn & Yahr stage (H&Y stage) and Schwab & England ADL scale(S&E ADL scale). Results : The whole group consists of 14 male patients and 21 female patients. Mean±SD age range is 64.5±8.4. There were no significant differences of the demographic and clinical characteristics between the case group and drop-out group. The mean±SD medical treatment period of the Case group were 8.4±6.3weeks, the mean±SD of the total score in first medical treatment UPDRS section 1~3 were 29.6±11.0, the mean±SD of the final score were 27.1±12.6, all of which showed significant improvement(p=0.007). There were no significant changes on the H&Y stage and S&E ADL scale. Conclusion : Patients with Parkinson's syndrome who visited Department of Cardiovascular and Neurologic diseases of Kyunghee Oriental Medical Center had a tendency of showing improvement in clinical symptoms.

  • PDF

Influence of varying cement types and abutment heights on pull-off force of zirconia restorations (시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향)

  • Yeong-Jun Jung;Yu-Lee Kim;Ji-Hye Jung;Nae-Un Kang;Hyun-Jun Kong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.64-71
    • /
    • 2024
  • Purpose: The purpose of this study is to evaluate Ti-base abutment's three different heights and three different cement types on the pull-off force of zirconia-based restorations. Materials and Methods: A total of 90 fixture lab analogs were embedded in auto polymerizing resin bloack. 90 Ti-base abutments heights of 3 mm, 5 mm, 7 mm were scanned and zirconia restoration were prepared from scanned files. Zirconia restoration were cemented with three different types of cements (temporary, semi-permanent, permanent) following manufacturer's instructions. All 90 specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using Kruskal-Wallis test for detecting whether there are any statistical significance along cement types or abutment heights. After that, Mann-Whitney test was used for figuring out differences regarding abutment height and the comparison between 3 cements. Results: Temp bond showed significantly lower pull-off force compared to Fujicem regardless of any abutment height. However, there were significant differences between Cem-implant and Fujicem in abutment height of 3 mm and 7 mm, but there was no significant difference in 5 mm. Temp bond and Cem-implant had significant differences only in abutment height of 5 mm. Conclusion: Although Ti-base abutment height did not influenced zirconia restorations' retentiveness, cement types showed significant differences.

A Study on Therapeutic Compliance of Hypertensive Patients in a Rural Health Subcenter (일개 농촌지역 보건지소 고혈압 환자의 치료지속성)

  • Song, Min-Keun
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.1
    • /
    • pp.155-164
    • /
    • 2002
  • Hypertension is the most frequent disease of chronic circulatory diseases and major intermediate cause or risk of the cerebrovascular disease which is a leading cause of death in Korea. Therefore, management of hypertension is an important issue in Korean healthcare. Especially, therapeutic compliance of hypertensives is very important because the hypertensive patients should receive anti-hypertensive treatment as long as the condition exists. However, many patients drop out of treatment, which is a major problem that needs to be solved through a hypertension control program. This study was carried out to provide basic data and counter measule for the hypertension control program in the community which aimed to keep the patients receiving treatment continuously. In order to investigate compliance of hypertensive patients during three months follow-up and the rate of control of hypertension, the data were collected during February, 2001, by reviewing medical records of 295 hypertensive patients who had been registered to Gunnam-myeon health subcenter before November, 2000. The author also study the dropout reasons by interviewing 58 patients among 68 dropout patients. The results were as follows: 1. Among the 295 subjects, 108(36.6%) were male and 187(63.4%) were female. Statistically, female hypertensives had a higher mean age than male(64.6 vs 66.3, p<0.05). 2. The 54.9% of the patients took anti-hypertensive medicine continuously for the past three months. And 19.3% had drug intermittently, and 25.8% dropped out of treatment. 3. Among several variables, such as sex, age, health insurance, the time taken from a patient's village to the health subcenter, only the last one was found to be significantly related to therapeutic compliance in the contingency table analysis. 4. The dropout reasons by multiple response were as follows, 'no symptom or no problem' (23.9%), 'change to other hospitals'(19.4%), 'geographical barrier'(17.9%), 'change to a neighborhood drugstore' (14.9%), 'immobility'(7.5%), 'economic barrier'(6.0%), 'unsatisfactory services of the health subcenter'(4.4%). 5. The mean blood pressure of 295 subjects was $144.9{\pm}12.9/86.88{\pm}8.6mmHg$. 6. The 32.5% of the subjects were controlled below 140/90mmHg. Conclusions: In order to improve the low rates of treatment and control of hypertension in rural hypertensives, a more active and systematic hypertension control program, including out-reaching follow-up management, is required in rural area. Especially, for health education of hypertensive patients, emphasis should placed on correcting wrong attitude toward hypertension.

  • PDF

Analysis of Acute Kidney Injury in Pediatric Patients with Stem Cell Transplantation (소아에서 조혈모세포이식 후 급성 신질환의 분석)

  • Kim, Sae-Yoon;Choi, Jung-Youn;Ha, Jeong-Ok;Park, Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.130-137
    • /
    • 2009
  • Purpose : Stem cell transplantation (SCT) has gained worldwide acceptance as a treatment for hematologic disorders. This study was performed to evaluate the clinical characteristics and outcomes of the acute kidney injury after SCT in children. Methods : The records of 53 patients who were treated with SCT at the pediatric department of Yeungnam University Hospital between January, 1996 and April, 2009 were used as subjects. Their were divided into two groups ; 'Early renal insufficiency' (ERI, n=18) and 'Non-early renal insufficiency' (NERI, n=35). ERI had greater than 25% of drop in GFR after SCT. Results: Total 53 patients were analyzed. In cord blood SCT (n=11), ERI was 4 (36.4%) and NERI was 7 (63.6%). In bone marrow SCT (n=16), ERI was 8 (50.0%) and NERI was 8 (50.5%). In autologous peripheral blood SCT (n=26), ERI was 6 (23.1%) and NERI was 20 (76.9%). There is no difference in both groups according to kinds of SCT. GVHD was developed in 22 patients, and there is no difference in each group. Twenty two of 53 patients died. ERI was 12 (66.7%) and NERI was 10 (28.6%). Acute renal failure is most important cause of the deaths. Conclusion : Out of 53 pediatric patients who were treated with SCT, 18 patients had greater than 25% of drop in GFR. There is no difference in both groups according to kinds of SCT. GVHD was found in 22 patients and there is no relation between GVHD development and acute kideney injury.

Rootzone Profile, Trickle Irrigation System and Turfgrass Species for Roof Turf Garden (옥상녹화에 적합한 지반, 점적 관수 및 잔디 선정)

  • 이재필;한인송;주영규;윤원종;정종일;장진혁;김두환
    • Asian Journal of Turfgrass Science
    • /
    • v.17 no.4
    • /
    • pp.155-163
    • /
    • 2003
  • This study was conducted to find out suitable rootzone profile, irrigation system, and turfgrass species for roof turf garden. Treatments of profile with soil amendment were Mixture I: Perlite(PL)60%+Vermiculite(VC)20%+Peatmoss(PM)20%, Mixture II: PL60%+VC 10%+PM20%+Sand(SD)10%, Mixture III: PL60%+VC20%+PM20% and Mixture IV: PL60%+VC10%+PM20%+SD10%+Styrofoam 5cm as a drain layer. To test trickle irrigation for roof garden, intervals of main pipe spacing(50cm, 100cm) and drop hole distance(15, 20, 30, 50 and 100cm)were treated, To select most suitable turfgrass species or mixture, Bermudagrass 'Konwoo', Zoysiagrass 'Konhee' and cool-season grass(Kentucky Bluegrass 80% + Perennial Ryegrass 20%, Tall Fescue 30% + KB50% + PR 20%)were tested. In particle size analysis, the soil amendments Perlite and vermiculite showed very even distribution, however, peatmoss contained mostly coarse particles with fiber over $\Phi$ 4.75mm. Under field moisture condition, vermiculite and peatmoss showed 350% water holding capacity, on the other hand, sand or Perlite showed 115% and 166%, respectively. Total weight of soil profile was 139.2kg/$m^2$ with Styrofoam drain layer without sand, which showed most lightest among treatments. Turf quality also resulted positve with Styrofoam drain layer installation. On trickle irrigation system, the proper interval of main drain pipe spacing and drop hole distance were 50cm and 50cm, respectively, In irrigation frequency, once per a day for 15 minute irrigation with 2 1/hr showed the best results on turf quality. Among turfgrass species or cool season grass mixture, warm season turfgrass fine leaf type zoysiagrass 'Konhee' and Bermudagrass 'Konwoo' showed very acceptable result on all over the treatments of rootzone and irrigation system. To apply cool season grasses for the roof garden, advanced researches may be needed to establish the proper soil amendment, rootzone profile, and irrigation system, Application of Bermudagrass 'Konwoo' for roof turf garden also needs successive tests to overcome winter injuries.

Effect of Lipid on the Protein Denaturation in Cooking Fish Meat (어육 조리시 지질이 단백질 변성에 미치는 영향)

  • LEE Kang-Ho;CHOI Byeong-Dae;RYU Hong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.5
    • /
    • pp.493-501
    • /
    • 1986
  • The present work aims to estimate the effect of heat treatment on the in vitro protein digestibility and formation of trypsin inhibitor or trypsin indigestible substrate(TIS) of raw and defatted flounder. It was also carried out to assess the formation of lipid-protein complexes under the conditions of different ratio of lipid addition. The in vitro protein digestibility increased when steamed for 5 min showing $88.09\%$ in raw and $90.56\%$ in defatted samples, respectively. After 40 min steaming, the digestibility decreased by $2{\sim}4\%$. As for microwaving, heating for 1 min resulted in slight increase of digestibility, however, heating for 7 min did decrease of digestibility by $3{\sim}4\%$ for both raw and defatted materials. There was no difference in fatty acid composition found with heat treatment. The major fatty acids of flounder meat were $C_{16:0},\;C_{16:1},\;C_{18:1},\;C_{20:5},\;C_{22:6}$ and the ratio of the unsaturated to saturated was 67.3:32.6. Fat oxidation and nonenzymatic browning were enhanced by heat treatment and protein solubility decreased necessarily as the brown pigment formation increased. On the other hand, the effects on the digestibility and TIS of the complexes formed from interaction of lipid and myofibrillar or meat protein of flounder were examined. The interaction of protein with lipid was considered to mostly contribute to the drop of digestibility of fish products. The digestibility of myofibrillar protein was $93.72\%$ for flounder, and it generally decreased as the amount of lipid added to protein and reaction time increased. Also mixed and heated samples were more active in digestibility decline than those mixed after heating. The result probably indicated that lipid-protein interaction was involved in the drop of digestibility which coincided with protein denaturation.

  • PDF

Differentiation of Human Embryonic Stem Cells into Germ Cell and Culture Condition for Single Embryonic Stem Cells Dissociated by Enzyme (인간 배아줄기세포의 생식세포로의 분화 및 효소에 의해 분리된 단일줄기세포 배양조건)

  • Chi, Hee-Jun;Choi, Soon-Young;Chung, Da-Yeon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • Objective: The present study was carried out to induce differentiation of human embryonic stem cells (hESCs) into germ cells and to establish a culture condition for single hESCs dissociated by enzyme. Methods: Embryonic body (EB) was formed by hanging drop culture for 3 days from hESCs colony. The EBs were cultured in the medium supplemented with retionic acid (RA) or/and bone morphogenetic protein-4 (BMP4) for 14 days to differentiate into germ cells. Germ cell specific markers, c-kit and VASA were used for immunohistochemistry of EB. Human ESCs colonies were dissociated into single cells by Collagenase, Tryple and Accutase, and then colony formation rate of the single cells was examined. Rho-associated kinase inhibitor (ROCK inhibitor, Y27632) was added into the culture medium of single cells to reduce the apoptotic damage during the dissociation. Results: Single cells dissociated with Tryple or Accutase showed higher colony formation rates compared to the cells dissociated with Collagenase. Seeding of $5{\times}10^3$ cells/well (4 well dish) was efficient to obtain high colony formation rate compared to other concentrations of seeding cell. Addition of Y27632 significantly increased the colony formation rate of the single cells dissociated by Tryple. Immunohistochemistry of EB with c-kit and VASA markers showed a weak fluorescence signals compared to the signals from the testicular tissue. Conclusion: Dissociation with Tryple was useful to obtain healthy single cells and addition of Y27632 was beneficial for survival and colony formation of the single cells. Unlike other studies, we just observed a dim fluorescence staining of the germ cell markers, probably caused by the short-term culture for the differentiation of EB compared to other studies.

Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol- (급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험-)

  • Kim, Seok-Chan;Lee, Sang-Hoak;Song, So-Hyang;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1296-1307
    • /
    • 1997
  • Background : Erdosteine is a thiol derivative developed for the treatement of chronic obstructive bronchitis, including acute infective exacerbation of chronic bronchitis. Erdosteine has mucomodulating and antioxidant properties and especially exhibits excellent gastrointestinal tolerability. Methods : The study was conducted as a prospective evaluation, with 2 comparative groups orally treated with erdosteine 300mg (bid.) or ambroxol 30mg (b.i.d.) for 7 days and the design of trial was double-blind. The treatments have been assigned randomly to patients (n=80) with acute or chronic bronchitis. The primary end-point used to determine efficacy in this study was subjective symptoms including expectorating frequence, expectoration volume, expectorating difficulty, expectoration viscosity, cough intensity and dyspnea. The secondary end-points of efficacy was the result of arterial blood gas analysis and pulmonary function test. Safety was evaluated with adverse drug reactions and laboratory tests monitoring. 61 patients was included in the efficacy analysis, due to the fact that 19 patients drop-out for different reasons. The obtained values have been analyzed with paired Hest., ANOVA test., multivariate $t^2$-test, repeated measures analysis of covariance, two sample t-test, loglinear-logit model analysis, Fisher's exact test. Results : 1) There was no significant difference on demographic data and vital signs between erdosteine and ambroxol treated groups. 2) The comparison between erdosteine and ambroxol treated groups showed no significant difference in improvement of each symptom in spite of the more favorable efficacy obtained with erdosteine. No difference on the contrary was observed for arterial blood gas analysis and pulmonary function test. 3) As safety is concerned, no clinical significant changes in laboratory test and symptom were induced in erdosteine and ambroxol treated group and two patients in ambroxol treated group drop-out for adverse reactions in symptom. 4) In the evaluation of final clinical efficacy, erdosteine improved more effectively patient's overall symptoms {very good effect (11/31), good effect (12/31), moderate effect (6/31), no effect (2/31), aggravation (0/31)} than ambroxol {very good effect (6/30), good effect (14/30), moderate effect (5/30), no effect (4/30), aggravation (2/30)}. And the probability of symptomatic improvement by erdosteine compared to ambroxol was 2.5 times. (p<0.05). Conclusion : This study showed that erdosteine was clinically effective and safe drug for treatment of acute and chronic bronchitis.

  • PDF

Evaluation for Soil Moisture Stabilization and Plant Growth Response in Horizontal Biofiltration System Depending on Wind Speed and Initial Soil Moisture (풍속과 초기 토양수분에 따른 평면형 바이오필터 내 토양수분 안정화 및 식물 생육반응 평가)

  • Choi, Bom;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.546-555
    • /
    • 2014
  • The final aim of this study is to develop a biofiltration system integrated with plant vegetation for improving indoor air quality effectively depending on indoor space and characteristics. However, to approach this final goal, several requirements such as constant pressure drops (PDs) and soil moisture contents (SMCs), which influence the capacity design for a proper ventilation rate of biofiltration system, should be satisfied. Thus, this fundamental experiment was carried out to adjust a proper wind speed and to ensure a stabilization of initial SMCs within biofilter for uniform distribution of SMCs and PDs, and for normal plant growth, especially avoiding root stress by wind. Therefore, we designed horizontal biofliter models and manufactured them, and then calculated the ventilation rate, air residence time, and air-liquid ration based on the biofilter depending on three levels of wind speed (1, 2, and $3cm{\cdot}s^{-1}$). The relative humidity (RH) and PD of the humidified air coming out through the soil within the biofilter, and SMC of the soil and plant growth parameters of lettuce and duffy fern grown within biofilter were measured depending on the three levels of wind speed. As a result of wind speed test, $3{\cdot}sec^{-1}$ was suitable to keep up a proper RH, SMC, and plant growth. Thus, the next experiment was set up to be two levels of initial SMCs (low and high initial SMC, 18.5 and 28.7%) within each biofilter operated and a non-biofiltered control (initial SMC, 29.7%) on the same wind speed ($3cm{\cdot}sec^{-1}$), and measured on the RH and PD of the air coming out through the soil within the biofilter, and SMC of the soil and plant growth parameters of Humata tyermani grown within biofilter. This result was similar to the first results on RHs, SMCs, and PDs keeping up with constant levels, and three SMCs did not show any significant difference on plant growth parameters. However, two biofiltered SMCs enhanced dry weights of the plants slightly than non-biofiltered SMC. Thus, the stability of this biofiler system keeping up major physical factors (SMC and PD) deserved to be adopted for designing an advanced integrated biofilter model in the near future.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.