• Title/Summary/Keyword: Drop in Center

Search Result 559, Processing Time 0.023 seconds

STUDY ON CALCULATION OF FLOW COEFFICIENT BY CFD FOR VALVE IN NUCLEAR POWER PLANT (전산유체역학을 활용한 원전용 밸브의 유량계수 산출에 대한 연구)

  • Kim, J.H.;Lee, J.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.54-60
    • /
    • 2016
  • The valve used in nuclear power plant must be qualified but the limitation of the test facility leads to use the numerical analysis. The flow coefficient is calculated with the consideration of the pressure, velocity and geometry. And the flow coefficient is the important physical property which is prepared using experiment or analysis by valve manufacturer. In this study, the analysis model was made according to ISA 75.02.01 and the mass flow rate and pressure drop ratio was calculated. The model of the expansion factor was applied to the simulation result and the pressure drop ratio at the start of the choked flow in the valve was found. With the simulation result, the consideration was performed that the expansion factor is the important physical property to the system engineer in addition to the flow coefficient.

A Study on Call Center Callers' Job Attitude and Turnover Intention

  • Lee, Seok-In;Lee, Su-Wha
    • International Journal of Contents
    • /
    • v.5 no.3
    • /
    • pp.1-7
    • /
    • 2009
  • The importance and the value of call center callers are increasing since they play very crucial roles as representatives of their companies at the closest contact point with customers. However, they have low satisfaction at work and are more likely to leave their jobs due to the fact that they are exhausted from heavy work load; they provide less pay and less chance for promotion than other jobs in the same industry. The high turnover costs companies high expenses on finding and training new callers. In the mean time, customer satisfaction may drop and it can give the customers negative image of the company. Therefore, solutions are required to keep the turnover of call center callers to the minimum. In this study, call center employees in Gwangju area were investigated for their job attitude and turnover intention. Based on the results, several implications are suggested.

Predicting Ability of Dynamic Balance in Construction Workers Based on Demographic Information and Anthropometric Dimensions

  • Abdolahi, Fateme H.;Variani, Ali S.;Varmazyar, Sakineh
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.511-516
    • /
    • 2021
  • Background: Difficulties in walking and balance are risk factors for falling. This study aimed to predict dynamic balance based on demographic information and anthropometric dimensions in construction workers. Methods: This descriptive-analytical study was conducted on 114 construction workers in 2020. First, the construction workers were asked to complete the demographic questionnaire determined in order to be included in the study. Then anthropometric dimensions were measured. The dynamic balance of participants was also assessed using the Y Balance test kit. Dynamic balance prediction was performed based on demographic information and anthropometric dimensions using multiple linear regression with SPSS software version 25. Results: The highest average normalized reach distances of YBT were in the anterior direction and were 92.23 ± 12.43% and 92.28 ± 9.26% for right and left foot, respectively. Both maximal and average normalized composite reach in the YBT in each leg were negatively correlated with leg length and navicular drop and positively correlated with the ratio of sitting height to leg length. In addition, multiple linear regressions showed that age, navicular drop, leg length, and foot surface could predict 23% of the variance in YBT average normalized composite reach of the right leg, and age, navicular drop, and leg length could predict 21% of that in the left leg among construction workers. Conclusion: Approximately one-fifth of the variability in the normalized composite reach of dynamic balance reach among construction workers using method YBT can be predicted by variables age, navicular drop, leg length, and foot surface.

Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir (저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실)

  • Bhang, Byeong Gwan;Woo, Sung Cheol;Lee, Wonbin;Choi, Jin Ho;Shin, SeungWook;Lee, ChulSung;Park, MiLan;Won, Changsub;Ahn, HyungKeun
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.

A Computer Programme Development for Thermal-Hydraulic Analysis and Optimal Design on LNG Pipeline System (LMG 배관시스템의 열유동 해석 및 최적설계 프로그램 개발)

  • Lee Sanggyu;Hong Seong-Ho;Lee Joong-Nam;Park Seok-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.7-14
    • /
    • 2000
  • LNG (Liquified Natural Gas) carried by LNG ship is unloaded into the LNG storage tanks at the very low temperature (a little lower than the boiling point of LNG). Because LNG is unloaded through the pipeline, two phase flow appears in the pipeline. In this study, we have studied the pressure-drop mechanisms of the two-phase flow in the pipeline, and the calculation method of BOG (Boil-off Gas) amount based on the heat transfer mechanism through the insulation and the surface of the pipeline. We have developed a computer program for thermal-hydraulic analysis on the LNG pipeline system. We have also developed the optimal design program to find the optimal thickness of insulation and the pipeline size. The program searches the optimal design with the minimum capital cost of pipelines and insulation on the operating conditions of maximum allowance pressure-drop and BOG amount, etc.

  • PDF

An Experimental and Numerical Study on Automotive IRDS Condenser (자동차용 IRDS 응축기에 대한 실험과 해석적 연구)

  • Kim, Hak-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.58-65
    • /
    • 2011
  • The specific objective of this study was to develop an IRDS (integrated receiver drier subcooling) condenser model for use in a mobile air-conditioning system. A three-zone model based on the desuperheating, two-phase, and subcooling sections of a condenser could be used to estimate the performance with a good accuracy. Overall heat transfer coefficients for each of the three sections, expressed as a function of the air velocity across the condenser and refrigerant mass flow rate and the model using the elemental difference method incorporate calculations to determine the pressure drop, heat performance within the condenser and it includes physical parameters (pass, tube hole size and length) that can be varied to analyze potential design changes without exhaustive experimental efforts. it was found that an accuracy of heat performance was within 5% in case of using the various condensers, the refrigerant pressure drop was predicted within 25% and the pressure drop of air side was well matched with experiment data within 4%.

Modeling of the Temperature-Dependent and Strain Rate-Dependent Dynamic Behavior of Glass Fiber-Reinforced Polyurethane Foams (유리 섬유 강화 폴리우레탄 폼의 온도 및 변형률 속도 의존 재료 거동 모델링)

  • Lee, Dong-Ju;Shin, Sang-Beom;Kim, Myung-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.547-555
    • /
    • 2019
  • The purpose of this study was to establish a numerical model of polyurethane foam (PUF) to simulate the dynamic response and strength of membrane-type Liquefied natural gas (LNG) Cargo containment system (CCS) under the impact load. To do this, initially, the visco-plastic behavior of PUF was characterized by testing the response of the PUF to the impact loads with various strain rates as well as PUF densities at room temperature and at cryogenic conditions. A PUF material model was established using the test results of the material and the FE analysis. To verify the validation of the established material model, simulations were performed for experimental applications, e.g., the dry drop test, and the results of FEA were compared to the experimental results. Based on this comparison, it was found that the dynamic response of PUF in dry drop tests, such as the reaction force and fracture behaviors, could be simulated successfully by the material model proposed in this study.

Flow Analysis of the Plain Seal with Injection (분사를 수반하는 평씨일 내의 유동해석)

  • 이관수;김우승;김기연;김창호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.795-802
    • /
    • 1992
  • A numerical analysis is performed on the turbulent flow in the plain seal with injection. The parameters used in this study are as follows : Reynolds number, rotation speed, injection speed, clearance ratio, injection angle, and axial injection location. Flow pattern and leakage performance due to the variation of parameters are investigated. SIMPLER algorithm is used to solve the Navier-Stokes equation governing steady, incompressible turbulent flow and standard K- .epsilon. turbulent model is used to consider the turbulence effects. The leakage performance is significantly enhanced with injection. The increases of the injection flow rate and be rotation speed of the shaft cause the leakage performance to the increased. With the increase of the Reynolds number the leakage performance is diminished. At the injection angle of 90deg, the leakage coefficient has a minimum value. The pressure drop has a maximum value at axial center location but the injection location has little effect on the pressure drop. Clearance ratio has a significant effect on the pressure drop.

Comparison of Metal Transfer Behavior in Electrodes for Shielded Metal Arc Welding

  • Xu, X.;Liu, S.;Bang, K.S.
    • International Journal of Korean Welding Society
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2004
  • Metal transfer behavior of three shielded metal arc welding electrodes, AWS El1018, E6013 and E6010, were investigated through the characterization of size distribution of droplets and measurement of arc voltage signals. Of the three electrodes, Ell018 electrode showed the largest droplet size with the smallest amount of spatter, while E6010 electrode showed the smallest droplet size with the largest amount of spatter. Even though Ell0l8 electrode showed a good agreement between the frequencies of voltage drop in FFT processed voltage signals and the transfer rate of droplets, E6013 and E6010 electrodes showed weaker correlation because of their dominant explosive transfer behavior. The type of cathode used and electrode baking time also influenced the metal transfer behavior. Compared to bead-on-plate welding using steel plate as a cathode, welding on a water-cooled copper pipe showed less short-circuiting and higher melting rate in all electrodes because of higher arc potential and/or anode drop. When baked for a long time, E6010 electrode showed much more stable arc with less short-circuiting and explosion due to the loss of gas formation ingredients.

  • PDF

Analysis of Auxiliary Device in a Gas-solid Cyclone by Experimental and Computational Approaches

  • Lee, Ju-Yeol;Park, Duck-Shin;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E1
    • /
    • pp.21-28
    • /
    • 2003
  • An auxiliary device, called Post Cyclone (PoC). had been introduced and primarily examined in earlier works which proved the reduction of the emission of fine dust from the gas-solid cyclones without incurring significant increase of cost and pressure drop. It has been known that the PoC has some advantages over other secondary dust treatment devices such as (a) simple design, (b) low cost of manufacture, (c) minimum additional pressure drop, (d) high recoverbility of the product dust, and (e) simplicity of operation. Despite the potential advantage, however, lack of practical data confined its plausible application in wide areas. Thus, in this work, a few serial experiments were conducted in terms of a few operation conditions, and the particle trajectories throughout the cyclone set-up were visually analyzed by using a commercial computer simulation program (FLUENT).