A Study on Power Flow Analysis of DC Traction Power Supply System with PWM Rectifier (PWM 정류기를 적용한 직류급전시스템의 조류계산에 대한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1919-1924
    • /
    • 2016
  • In general, Diode rectifier has been applied to DC traction power supply system. Diode has some characteristics which is voltage drop in inverse proportion of load because of non-controlled switch, and cannot flow a current in reverse bias. So, voltage drop occurs frequently, and regenerated power cannot use in substation. The PWM rectifier is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper proposes analysis algorithm for DC traction power supply system with PWM rectifier.

Drop-Impact Analysis and Design of a Package of a Microwave Oven (전자레인지 포장품의 낙하충격 해석 및 설계)

  • Kim, Won-Jin;Lee, Boo-Youn;Son, Byung-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.536-543
    • /
    • 2009
  • Dynamic behaviour of a package of a microwave oven under the drop-impact conditions is evaluated by the finite element analysis and tests. PAM-CRASH software is used for the finite element analysis and the tests are performed according to the ISTA(International Safe Transit Association) specification. Results of the analyses are compared with those of the tests and accuracy is shown to be favourable. Under the drop-impact condition of the original design, severe deformation occurs and an improved design is proposed to reduce it. The approach presented in this research can be successfully applied to reduce costs and time required to develop new models of the microwave oven.

Analysis of Chemical Warfare Agents in Water Using Single-Drop Microextraction

  • Park, Yang-Gi;Kim, Sung-Ki;Choi, Ki-Hwan;Son, Byung-Hoon;Park, Ju-Sub;Kang, Hong-Ku
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.49-52
    • /
    • 2009
  • Single-drop microextraction (SDME) is an extraction methodology where the drop plays an essential role as extracts. It was evaluated for the GC-MS determination of nerve agents, one class of the chemical warfare agents (CWAs). Since these nerve agents are highly toxic, it is important to detect the nerve agents in the environmental samples. Several affecting factors including extraction solvents, stirring rate, extraction time, and amounts of salt were optimized. The limit of detections (LODs) were 0.1 - 10 ng/mL and the relative standard deviations (RSDs%, n=5) were in the range of 6.3% to 9.0% for four nerve agents. Without pretreatment of the environmental samples, 5-103 fold enrichments and 48-100% recovery were accomplished. These results demonstrated the feasibility of this method for on-site and off-site analysis of water sample collected from suspicious CWAs site.

Fracture mechanics analysis of multipurpose canister for spent nuclear fuels under horizontal/oblique drop accidents

  • Jae-Yoon Jeong;Cheol-Ho Kim;Hune-Tae Kim;Ji-Hye Kim;Yun-Jae Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4647-4658
    • /
    • 2023
  • In this paper, elastic-plastic fracture mechanics analysis is performed to determine the critical crack sizes of the multipurpose canister (MPC) manufactured using austenitic stainless steel under dynamic loading conditions that simulate drop accidents. Firstly, dynamic finite element (FE) analysis is performed using Abaqus v.2018 with the KORAD (Korea Radioactive Waste Agency)-21 model under two drop accident conditions. Through the FE analysis, critical locations and through-thickness stress distributions in the MPC are identified, where the maximum plastic strain occurs during impact loadings. Then, the evaluation using the failure assessment diagram (FAD) is performed by postulating an external surface crack at the critical location to determine the critical crack depth. It is found that, for the drop cases considered in this paper, the principal failure mechanism for the circumferential surface crack is found to be the plastic collapse due to dominant high bending axial stress in the thickness. For axial cracks, the plastic collapse is also the dominant failure mechanism due to high membrane hoop stress, followed by the ductile tearing analysis. When incorporating the strain rate effect on yield strength and fracture toughness, the critical crack depth increases from 10 to 20%.

Two-way Shear Behavior Analysis of Transfer Slab-Column Connection with Reverse Drop Panel Through Nonlinear FE Analysis (역드랍 패널 적용 전이슬래브-기둥 접합부의 비선형 유한요소해석을 통한 2면 전단거동 분석)

  • Jeong, Seong-Hun;Kang, Su-Min;Kim, Seung-Il;Lee, Chang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.2
    • /
    • pp.103-111
    • /
    • 2020
  • Recently, the use of transfer slab system has increased greatly. However, several construction problems are being encountered owing to its excessive thickness. Therefore, in this study, a transfer slab system that uses a reverse drop panel, which can utilize the facility space of the pit floor by reducing the transfer slab thickness, was considered. To investigate the shear behavior of transfer slab system that uses the reverse drop panel, the two-way shear strength of transfer slab-column connection with the reverse drop panel was analyzed using nonlinear FE analysis. In addition, the two-way shear strength evaluations of transfer slab with the reverse drop panel conducted using the existing evaluation methods were verified by comparing the strengths predicted by those methods with the results of nonlinear FE analysis.

Pressure Drop in a Circular Pipe of Waste Collection Piping System (쓰레기 관로 이송 시스템의 관로 압력강하 평가)

  • Jang, Choon-Man;Lee, Sang-Yun;Suh, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.55-60
    • /
    • 2007
  • This paper describes an evaluation method of pressure drop in a circular pipe of waste collection piping system. Accurate pressure drop in a piping system is very important to determine the capacity of turbo blower, which is one of the main elements in the system. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure drop in the piping system. Organic waste is selected and modeled using the result of site survey performed in an apartment area. Evaluation method of pressure drop used In the present numerical simulation is performed in the shortened pipe line prior to the calculation of the real system. Throughout the numerical simulation, pressure drop in a waste pipe is obtained and compared to the value determined by analytical method. The pressure drop obtained by numerical simulation has a good agreement with that of the analytic method. It is noted that present evaluation method is effective to determine a pressure drop in the piping system. Detailed flow characteristics inside the pipe line are also analyzed and discussed.

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I))

  • Kim, Joo-Rak;Lee, Chang-Mu;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

A Study on One Factorial Longitudinal Data Analysis with Informative Drop-out

  • Lee, Ki-Hoon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1053-1065
    • /
    • 2006
  • This paper proposes a method in one-way layouts for longitudinal data with informative drop-out. When dropouts are informative, that is, correlated with unobserved data and/or the previous observed data, the simple imputation methods such as 'last observation carried forward' (LOCF) methods would arise the bias of the testing models. The maximum likelihood procedure combined with a logit model for the drop-out process is proposed to test treatment effects for one factorial designs and compared with LOCF method in two examples.

  • PDF

Drop Test of an Oleo-pneumatic Landing Gear (유공압 착륙장치 낙하시험)

  • Kim, Tae-Uk;Lee, Sang-Wook;Shin, Jeong-Woo;Lee, Seung-Kyu;Kim, Sung-Chan;Hwang, In-Hee;Kang, Shin-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1130-1135
    • /
    • 2010
  • The main function of a landing gear is to absorb the impact energy during touchdown. Most landing gear use an oleo-pneumatic shock absorber which essentially consists of an oil damper and a gas spring. The performance of a shock absorber can be estimated by analysis but it should be verified by drop test, which is required by MIL Spec. and FAR. In the drop test, various data such as ground loads, shock absorber pressure, stroke and mass travel are analyzed to validate the shock absorbing efficiency and the mathematical model for analysis. This paper presents the introduction of drop test facility, the test procedure and data evaluation method with real drop test example.

Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

  • Jung, Mi-Jin;Shin, Yeon-Jae;Oh, Se-Yeon;Kim, Nam-Sun;Kim, Kun;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.231-236
    • /
    • 2006
  • A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 $\mu$L. 60 min extraction time at 25 ${^{\circ}C}$ was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant ($K_{lh}$) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, $\beta$-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.