• 제목/요약/키워드: Drop analysis

검색결과 1,883건 처리시간 0.033초

Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석 (Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution)

  • 김병호;한도희;서숭혁
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.

발 뒤꿈치 충격에 의한 전단벽식 공동주택 수직진동의 수직방향 진동전달 특성 (Characteristics of Vertical Vibration Transfer in Vertical Way according to Shear Wall Apartment Structures due to Heel-drop Impact)

  • 전호민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.70-73
    • /
    • 2006
  • Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to heel-drop impact forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on two shear wall building structures. The results of this study suggest that the characteristics of vertical vibration transfer are similar in terms of the directions of transfer.

  • PDF

연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구 (A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition)

  • 김주락
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

산업용 잉크젯 압전프린트 헤드의 특성해석 및 잉크 망점제어에 의한 PCB 전기회로패턴 공정개선 (Process Improvement of PCB Electric Circuit Pattern by Ink Drop Jetting Control and Characteristics Analysis of Industrial Inkjet Piezoelectric Print Head)

  • 윤신용
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.57-65
    • /
    • 2016
  • This paper was analyzed the characteristics of piezoelectric inkjet print head using finite element method(FEM). It showed the bending node driving of piezoelectric and relation theory principle consider piezoelectric material characteristics and ink characteristics. From such result we were had the piezoelectric head design and manufacture. It got a this head characteristics through experiment, we confirmed that proper voltage control is possible to through ink drop control experiment of piezoelectric print head. This paper was obtained the suitable ink jetting characteristics that manufacture the control circuit and piezoelectric inkjet print head. This practice product was applied to improvement of PCB electric circuit pattern by etching resist ink that PCB manufactured to complex process over traditional 6 stages can be simpled to 1 stage by inkjet printing technology.

가솔린 엔진용 배기매니버터 유동특성 해석 및 시험에 관한 연구 (CFD ANALYSIS AND EXPERIMENT OF EXHAUST MANIVERTER OF GASOLINE ENGINE)

  • 엄용석;박남섭;신철균;이점주;이관순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.468-472
    • /
    • 2010
  • To develop the Exhaust Maniverter(Manifold and converter) it needs to consider flow characteristics related to durability and performance of the catalyst, manufacturability, etc. This paper presents the analysis results regarding to flow characteristics such as flow uniformity, tangential speed, O2 sensor sensitivity and CHT (conjugate heat transfer) for the LCF(Low Cycle Fatigue) for gasoline 2.0 liter engine. The results are satisfactorily corresponded to the general criteria. Also skin temperature and pressure drop wire measured at the Engine Bench. These results can be useful for the design guide for Exhaust Maniverter.

  • PDF

An analysis of new IGBT(Insulator Gate Bipolar Transistor) structure having a additional recessedwith E-field shielding layer

  • 유승우;이한신;강이구;성만영
    • 전기전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.247-251
    • /
    • 2007
  • The recessed gate IGBT has a lower on-state voltage drop compared with the DMOS IGBT, because there is no JFET resistance. But because of the electric field concentration in the corner of the gate edge, the breakdown voltage decreases. This paper is about the new structure to effectively improve the Vce(sat) voltage without breakdown voltage drop in 1700V NPT type recessed gate IGBT with p floating shielding layer. For the fabrication of the recessed gate IGBT with p floating shielding layer, it is necessary to perform the only one implant step for the shielding layer. Analysis on the Breakdown voltage shows the improved values compared to the conventional recessed gate IGBT structures. The result shows the improvement on Breakdown voltage without worsening other characteristics of the device. The electrical characteristics were studied by MEDICI simulation results.

  • PDF

병렬 마이크로 채널 형상에 따른 CFD 유동해석 (CFD Analysis on the Channel Shapes of Parallel Micro-Channels)

  • 최용석;임태우;김유택;김도엽
    • 수산해양교육연구
    • /
    • 제25권5호
    • /
    • pp.1102-1109
    • /
    • 2013
  • An numerical analysis was performed to obtain the design parameters for parallel micro-channels. The parallel micro-channels consist of 10 square channels with a hydraulic diameter of 300 ${\mu}m$ and inlet/outlet manifolds. The channel length is 5mm, 10mm and 40mm respectively. Mass flux was set between 200~600kg/m2s as inlet boundary condition and atmospheric pressure was set as outlet boundary condition. The pressure drop in channels and manifolds were estimated by using the Shah and London correlation and the flow uniformity was represented by the velocity distributions with dimensionless velocity. The results show that the flow uniformity in channels depends on shapes of manifolds, length and mass flux.

패스변화에 따른 워터블록의 열전달 및 유동특성 평가 (Heat Transfer and Fluid Flow Evaluation of Microchannel Waterblock with Pass Variations)

  • 최진태;권오경;최미진;윤재호;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1135-1140
    • /
    • 2009
  • The present study has been studied on a thermal and flow characteristic of the microchannel waterblock with pass variations in 8 samples. Results of a numerical analysis using the CFX-11 were compared with results of an experiment. Numerical analysis and experiment were conducted under an input power of 150 W, inlet temperature of $35^{\circ}C$ and mass flow rates of $0.7{\sim}2.0\;kg/min$. The numerical results showed reasonably good agreement with the experimental results within about $3{\sim}5%$. Also, the numerical results showed that the sample 2 types with the 2 pass gave better performance than the sample 1 types with the 1 pass from the viewpoints of heat transfer and pressure drop.

  • PDF

입자 형상에 따른 관내 차압의 전산해석 (COMPUTATIONAL ANALYSIS OF PRESSURE DROP IN PIPE ACCORDING TO PARTICLE SHAPES)

  • 유승영;성형건;장진성;노태성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.41-45
    • /
    • 2011
  • Pressure drops of two-phase flow in a pipe according to particle shapes have been calculated and analyzed. The numerical analysis for 3 cases of Reynolds number has been conducted for each particle shape. In case of the cylinder shape, the particles had been assumed to be randomly distributed for each Reynolds number. The results have been averaged and compared to those of the case of the ball shape. Additionally, pressure drops of ball and cylinder shapes has been compared to the result of Ergun's equation.

  • PDF

다양한 형상의 판형 휜을 장착한 원통다관형 열교환기의 열성능 해석 (Thermal Performance Analysis of a Shell-and-Tube Heat Exchanger with Plate Fins of Various Shape)

  • 신지영;손영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.648-656
    • /
    • 2004
  • In this study, a highly efficient shell-and-tube heat exchanger with plate fins is considered to improve thermal performance of the conventional shell-and-tube heat exchanger. This type of shell-and-tube heat exchanger with plate fins of various shape is simulated three-dimensionally using a commercial thermal-fluid analysis code. CFX4.4. The effect of the shape of the plate fin on heat transfer characteristics is also investigated by the simulation. Plate fins of four different shapes. plane, plane-slit. wave. and wave-slit fins, are considered. The flow fields, pressure drop and heat transfer characteristics in the heat exchanger are calculated. It is proved that the shell-and-tube heat exchanger with plate fins is superior to the conventional shell-and-tube heat exchanger without plate fins in terms of heat transfer. The shape of the plate fin is important in the performance of a heat exchanger such as heat transfer and pressure drop.