• 제목/요약/키워드: Drop analysis

검색결과 1,888건 처리시간 0.024초

드롭 착지와 착지 후 점프 시 충격흡수 기전의 차이 분석 (Analysis of the Differences of the Shock Absorption Strategy between Drop-Landing and Countermovement-Jump)

  • 조준행;김경훈;고영철
    • 한국운동역학회지
    • /
    • 제22권4호
    • /
    • pp.379-386
    • /
    • 2012
  • The aim of this study was to investigate and identify the differences in lower extremity energy dissipation strategies between drop-landing and countermovement-jump maneuvers. Fourteen recreational athletes(Age : $23.3{\pm}2.1years$, Height : $172.3{\pm}4.0cm$, Weight : $69.2{\pm}4.7kg$) were recruited and instructed to perform drop-landing from 45 cm height and countermovement-jump from 45 cm to 20 cm height. The landing phase was taken as the time between initial contact and peak knee flexion. A motion-capture system consisting of eight infra-red cameras was employed to collect kinematics data at a sampling rate of 200 Hz and a force-plate was used to collect GRF data at a sampling rate of 2000 Hz. Paired t-test was performed to determine the difference in kinematics and kinetics variables between each task. During the countermovement-jump task, all of lower extremity joint ROM and the hip joint eccentric moment were decreased and the ankle joint plantarflexion moment was increased than drop-landing task. In the eccentric work during countermovement-jump task, the ankle joint displayed greater while knee and hip joint showed lesser than drop-landing. Therefore, the knee joint acted as the key energy dissipater during drop-landing while the ankle joint contributed the most energy dissipation during countermovement-jump. Our findings collectively indicated that different energy dissipation strategies were adopted for drop-landing and countermovement-jump.

균일전기장에 의한 기포와 액적의 변형에 관한 연구 (A study on the deformation of a bubble and a drop in a uniform electric field)

  • 권영철;김무환;강인석;조혜정;김석준
    • 대한기계학회논문집B
    • /
    • 제20권6호
    • /
    • pp.2023-2035
    • /
    • 1996
  • In the present study, the characteristics of the electrical deformation of a bubble and a drop under a uniform electric field have been investigated to understand EHD heat transfer enhancement by an electric field. The deformation of the bubble and the drop have been studied theoretically using an electric normal stress acting on their interfaces and assured by the numerical analysis and the experiment. From the variation of bubble volume and free energy, it is found that a bubble is compressed in an electric field and free energy had larger value with increasing W and the permittivity of a dielectric fluid. The electric normal stress induced on the interface of the bubble and the drop is different. Because of the surface charge induced at the drop interface, the electric normal stress acting on the drop is much larger than that of the bubble. The drop is, therefore, deformed much more than the bubble. In addition, the experimental and numerical results show that the aspect ratio and the contact angle of the bubble increase with increasing W.

발등굽힘근 촉진 다이나믹 테이핑이 발 처짐이 있는 뇌졸중 환자의 정적, 동적 균형과 보행 속도에 미치는 즉각적 효과 (Immediate Effects of Ankle Dorsiflexor Facilitation Dynamic Taping on Static and Dynamic Balance and Gait Speed in Stroke Patients With Foot Drop)

  • 임진구;김선엽
    • 한국전문물리치료학회지
    • /
    • 제29권1호
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Foot drop is a common symptom in stroke patients. Tape applications are widely used to manage foot drop symptoms. Previous studies have evaluated the effects of static and dynamic balance and gait on foot drop using kinesiology tape; however, only few studies have used dynamic tape application in stroke patients with foot drop. Objects: The purpose of this study was to investigate the immediate effects of dynamic taping, which facilitates the dorsiflexor muscle, on static and dynamic balance and gait speed in stroke patients with foot drop. Methods: The study included 34 voluntary patients (17 men, 17 women) with stroke. The patients were randomly assigned to the experimental group (n = 17), wherein dynamic taping was used to facilitate the dorsiflexor muscle, or the control group (n = 17), wherein kinesiology taping was used. Before the taping application, velocity average, path-length average, Berg balance scale, and timed up and go test (TUG) were recorded to measure static and dynamic balance, whereas the 10-meter walk test (10MWT) was used to measure gait speed. After the taping application, these parameters were re-evaluated in both groups. Repeated measure analysis of variance was used. Statistical significance levels were set to α = 0.05. Results: Except for the 10MWT scores in the control group, significant differences were noted in all the parameters measured for static and dynamic balance and gait speed between the pre and post-test (p < 0.05). However, the parameters showed significant interaction effects between group and time in the TUG and 10MWT (p < 0.01). Conclusion: These results indicate that compared with kinesiology taping, dynamic taping used in chronic stroke patients with foot drop had a more significant effect on dynamic balance and gait speed.

V자형 낙차공 모형 직하류 국부세굴공 발생특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Local Scour Hole Downstream of V-shaped Drop Structure Model)

  • 엄중현;한형준;박성원;안정규
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.8-14
    • /
    • 2019
  • 대표적인 하천횡단구조물 중 하나인 낙차공은 하천하상의 안정을 목적으로 설치되지만 이는 하천환경의 연속성을 차단하고, 수생태환경의 파괴를 야기하는 것으로 알려져 있다. 따라서 본 연구에서는 생태통로로서의 기능을 갖는 저낙차 자연형 낙차공을 모형으로 제작하여 실험실 실험을 수행하고, 적절한 지배인자 사이의 관계를 도출하여 국부세굴공 규모의 예측식을 제안하였다. 직선형과 6가지 상향 V 자형의 낙차공 모형에 대하여 각각 실험유량은 4가지로 총 28개의 조건에 대해서 실험을 수행하였다. 각각의 실험조건별 세굴실험 결과를 바탕으로 기존에 제안된 세굴심 추정식을 적용한 결과보다 최대세굴심이 다소 크게 발생함을 확인하였다. 따라서 낙차공 직하류부에서 발생하는 세굴공 발생 주요인자들 사이의 상관관계를 분석한 결과, 낙차공으로의 유입흐름 특성과 낙차공의 높이, 낙차공의 총횡단길이와의 상관관계가 높게 나타남을 확인하였다. 또한 이를 토대로 각 실험조건별 세굴심과 세굴길이에 상관관계가 높다고 판단되는 변수들을 무차원화하여 최대세굴공의 깊이와 길이 산정식을 각각 제안하였다. 향후 추가적으로 다양한 하상토 재료와 수심변화를 고려한 실험적 연구 및 수치해석 연구를 병행하여 보다 정확한 세굴심 산정식을 도출할 수 있다.

저궤도 인공위성 탑재체 구동에 따른 버스 전압 강하 해석 (Bus Voltage Drop Analysis Caused by Payload Operation of LEO Satellite)

  • 박희성;장진백;박성우;이상곤
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.57-62
    • /
    • 2010
  • 저궤도 인공위성에서 SAR 위성 탑재체의 전류 소모량이 약 150A로 예측된다. 이러한 높은 전류 소모는 배터리-위성버스-탑재체로 이루어진 인터페이스에서 전압 강하를 유기하여 위성 본체의 전장품과 탑재체의 동작 전압을 낮추게 되어 정상 동작을 보장하지 못하게 된다. 따라서, 탑재체 동작에 따른 버스 전압과 탑재체 입력 전압 강하의 예측이 반드시 필요하다. 본 해석에서는 전압강하의 요인이 될 수 있는 하니스 및 접촉 저항에 대한 worst case analysis를 수행하여 탑재체 동작시 발생할 수 있는 전압 강하를 예측한다.

A comparative analysis of sheeting die geometries using numerical simulations

  • Igali, Dastan;Wei, Dongming;Zhang, Dichuan;Perveen, Asma
    • Advances in Computational Design
    • /
    • 제5권2호
    • /
    • pp.111-125
    • /
    • 2020
  • The flow behavior of polymer melts within a slit die is an important consideration when designing a die geometry. The quality of the extruded polymer product can be determined through an evaluation of the flow homogeneity, wall shear rate and pressure drop across the central height of the die. However, mathematical formulations cannot fully determine the behavior of the flow due to the complex nature of fluid dynamics and the nonlinear physical properties of the polymer melts. This paper examines two slit die geometries in terms of outlet velocity uniformity, shear rate uniformity at the walls and pressure drop by using the licensed computational fluid dynamics package, Ansys POLYFLOW, based on the finite element method. The Carreau-Yasuda viscosity model was used for the rheological properties of the polypropylene. Comparative analysis of the simulation results will conclude that the modified die design performs better in all three aspects providing uniform exit velocity, uniform wall shear rates, and lower pressure drop.

Store Separation Analysis of a Fighter Aircraft's External Fuel Tank

  • Cho, Hwan-Kee;Kang, Chi-Hang;Jang, Young-Il;Lee, Sang-Hyun;Kim, Kwang-Yeon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권4호
    • /
    • pp.345-350
    • /
    • 2010
  • The repetitive vibrating action of an aerodynamic load causes an external fuel tank's horizontal fin to experience a shorter life cycle than its originally predicted one. Store separation analysis is needed to redesign the fin of an external fuel tank. In this research, free-drop tests were conducted using 15% scaled models in a subsonic wind tunnel in order to analyze the store separation characteristics of an external fuel tank. The store separation trajectory based on grid tests was also obtained to verify the results of the free-drop tests. The results acquired from the free-drop tests correlated well with the grid tests in regards to the trajectories and behavior of the stores separated from the aircraft. This agreement was especially noted in the early stages of the store separation.

DETAILED EXAMINATION OF INVERSE-ANALYSIS PARAMETERS FOR PARTICLE TRAPPING IN SINGLE CHANNEL DIESEL PARTICULATE FILTER

  • Jung, S.C.;Park, J.S.;Yoon, W.S.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.165-177
    • /
    • 2007
  • Predictions of diesel particulate filtration are typically made by modeling of a particle collection, and providing particle trapping levels in terms of a pressure drop. In the present study, a series of single channel diesel particulate filter (DPF) experiments are conducted, the pressure traces are inversely analyzed and essential filtration parameters are deducted for model closure. A DPF filtration model is formulated with a non-linear description of soot cake regression. Dependence of soot cake porosity, packing density, permeability, and soot density in filter walls on convective-diffusive particle transportation is examined. Sensitivity analysis was conducted on model parameters, relevant to the mode of transition. Soot cake porosity and soot packing density show low degrees of dispersion with respect to the Peclet number and have asymptotes at 0.97 and $70\;kg/m^3$, respectively, at high Peclet number. Soot density in the filter wall, which is inversely proportional to filter wall Peclet number, controls the filtration mode transition but exerts no influence on termination pressure drop. The percolation constant greatly alters the extent of pressure drop, but is insensitive to volumetric flow rate or temperature of exhaust gas at fixed operation mode.

Parametric study on the structural response of a high burnup spent nuclear fuel rod under drop impact considering post-irradiated fuel conditions

  • Almomani, Belal;Kim, Seyeon;Jang, Dongchan;Lee, Sanghoon
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1079-1092
    • /
    • 2020
  • A parametric study of several parameters relevant to design safety on the spent nuclear fuel (SNF) rod response under a drop accident is presented. In the view of the complexity of interactions between the independent safety-related parameters, a factorial design of experiment is employed as an efficient method to investigate the main effects and the interactions between them. A detailed single full-length fuel rod is used with consideration of post-irradiated fuel conditions under horizontal and vertical free-drops onto an unyielding surface using finite-element analysis. Critical drop heights and critical g-loads that yield the threshold plastic strain in the cladding are numerically estimated to evaluate the fuel rod structural resistance to impact load. The combinatory effects of four uncertain parameters (pellet-cladding interfacial bonding, material properties, spacer grid stiffness, rod internal pressure) and the interactions between them on the fuel rod response are investigated. The principal finding of this research showed that the effects of above-mentioned parameters on the load-carrying capacity of fuel rod are significantly different. This study could help to prioritize the importance of data in managing and studying the structural integrity of the SNF.

경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (II) (Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (II))

  • 김주락;창상훈;박현준;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1984-1990
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF