• Title/Summary/Keyword: Drop analysis

Search Result 1,888, Processing Time 0.042 seconds

A Study on a New Power Flow Method for Analysis of AC Electric Railway System and Improvement of Voltage Drop Using a STATCOM (교류 전기철도 시스템의 해석에 적합한 조류계산 기법 및 STATCOM을 적용한 전압 강하 개선 연구)

  • Baek, Jung-Myoung;Lee, Byung-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.669-676
    • /
    • 2007
  • This paper presents a new power flow method to analyze the AC electric railway system effectively in both cases of traction and regenerative braking of the trains. The algorithm to easily solve the power flow of the AC electric railway system with the trains of regenerative braking from the system without a train of regenerative braking is derived. Using this new power flow method, the voltage characteristics of a typical AC electric railway system is easily analyzed in both cases of traction and regenerative braking of the trains. We show that the presented method can be applied effectively in order to analyze the AT-fed AC electric railway system in both cases of traction and regenerative braking of the trains. A STATCOM(Static Synchronous Compensator) is applied to the system in order to improve the voltage drop problem and this case is also analyzed to show the effect of STATCOM.

Application Method Analysis at Voltage Drop Calculations on Low Voltage Feeder by IEC Standard (국제 표준에 따른 저압간선 전압강하 계산시 적용 방법 고찰)

  • Kim, Gi-Hyun;Lee, Ju-Chul;Choi, Young-Kyu;Kim, Han-Soo;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.53-58
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest application method and review items at calculations for voltage drop calculations on low voltage feeder by IEC 60364, BS 7671 standard and Consumer's Electrical Installation Guide.

Development of an Active Controlled Ankle-Foot-Orthosis for Paralysis Patients (마비 환자를 위한 능동형 달하지 보조기의 개발)

  • Hwang, Sung-Jae;Kim, Jung-Yoon;Kim, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.193-195
    • /
    • 2006
  • In this study, we developed an active controlled ankle-foot orthosis(AAFO) which can control the dorsiflexion/plantarflexion of the ankle joint during gait to prevent foot drop and toe drag for paralysis patients. To prevent dropping foot after heel strike, ankle joint was actively controlled to minimize forefoot collision with the ground. It was also controlled to provide toe clearance and to help push-off during late stance. The 3D gait analysis was performed on two healthy subjects equipped with the developed AAFO to compare with the normal gait and the conventional AFO gait. In the developed AAFO gait, differently from the conventional AFO gait, significant push-off was observed during pre-swing and the maximum flexion moment during pre-swing phase was similar to that of normal gait. A remarkable dorsiflexion also occurred during initial swing. These results indicated that the developed AAFO could have certain clinical benefits to prevent foot drop for paralysis patients, compared to conventional AFOs.

  • PDF

Prediction of drop size by analysis of conical liquid sheet breakup (원추형 액막분열 해석에 의한 액적 크기 예측)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.8-17
    • /
    • 1997
  • A study has been carried out on the instability of a conical liquid sheet by using the linear instability theory. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed the the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. The predicted drop size agreed well with the measured Sauter mean diameter, $D_{32}$.

  • PDF

NUMERICAL STUDY ON HEAT TRANSFER CHARACTERISTICS FOR RING TYPE HEAT EXCHANGER (링형 열교환기의 열전달특성에 관한 수치적 연구)

  • Dong, W.R.;Choi, H.K.;Yoo, G.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.143-147
    • /
    • 2008
  • Numerical analysis is performed to find flow and heat transfer characteristics for ring type heat exchanger. 3-D numerical predictions are carried out for the ring type heat exchanger system with Reynolds number varying in the range of 1,000 and 10,000. From the prediction, streamwise velocity, pressure drop, flow rate and heat transfer coefficient are analyzed. It is also found that characteristics of pressure drop and heat transfer generally follow well proportional variations of Re$m^$for the wide range of Reynolds number considered in this study.

  • PDF

A study on the Characteristics of the Blowing type Rotary Burner (송풍형 로터리 버너의 특성 연구)

  • Choi Y. H.;Kim K. H.;Yoon S. J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.303-306
    • /
    • 2002
  • Liquid atomization by means of a spinning cup is widely used as a device for combustion, in cooling and spray drying. In this study, the blowing type rotary atomizer was experimental carried out the investigations on the characteristics of the blowing type rotary atomizer which is an air flow energy of blower instead of an electric motor most commonly used to a driven energy. The analysis on the rotary cup speed, air velocity with the blower conditions was performed and also the drop size was measured using LDPA. It was tried to analyzed on air-nozzle size and liquid flowrate as the result. It was found that the increase of the relative velocity between liquid and air improve significantly atomization liquid, and decrease of the liquid flowrate improved the maximum drop size though the mean drop size is really the same.

  • PDF

Flow Analysis of Heat Exchanger with Delta Winglet Vortex Generators on CFD (와류 생성기가 설치된 핀 튜브 열교환기의 열 유동해석)

  • Hwang, Seong-Won;Jeong, Ji-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1166-1171
    • /
    • 2009
  • Fin-tube heat exchangers are widely used in refrigeration systems. To improve the performance of fin-tube heat exchangers, the shape of plain fin was developed in slit fin and louver fin. These pins have higher heat transfer performance as well as larger pressure drop. Recent studies of a delta winglet vortex generators(DWVG) show less heat transfer capacity than louver fin. However, the DWVG have very small pressure drop. This paper compares the performance for the plain fin and DWVG fin in terms of flow characteristics and heat transfer based on CFD analyses. The DWVG generate vortex and delayed flow separation and leads to a reduction of a wake region behind a tube. The results show that the DWVG produce improved heat transfer and reduced pressure drop compared to a plain fin. This result is opposite to the Reynolds analogy.

  • PDF

Acceleration Test of Ion Migration for PCB Electronic Reliability Evaluation (PCB 전기적 신뢰성평가를 위한 이온 마이그레이션 가속시험)

  • Lee, D.B.;Kim, J.H.;Kang, S.K.;Chang, S.W.;Lim, J.H.;Ryu, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-69
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Print Circuit Borad),electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs in the environment of the hight humidity and the hight temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on electrolyte quantity which included in the various waters.

  • PDF

Design and Analysis of a VOD Buffer Scheduler Using a Fixed Prefetch and Media Drop (고정 선반입과 미디어 Drop을 이용한 VOD 버퍼 스케쥴러의 설계 및 분석)

  • 문병철;박규석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.110-112
    • /
    • 2000
  • VBR로 압축된 멀티미디어 데이터는 비트 변화율이 매우 큰 편차로 변하기 때문에 자원 예약 관리가 매우 힘들다. 따라서 MPEG데이터의 참조 패턴을 오프라인으로 분석한 메타 테이블을 근거로 과부하 구간에서 미리 선반입하여 시스템의 활용율을 높이는 선반입 기법을 사용하고 있으나, 기존의 선반입 기법은 상영실패는 발생하지 않지만 선반입 임계슬롯이 증가하면서 버퍼 점유량이 증가되어 최소의 적재시간과 적재비용을 유지할 수 없다. 따라서 본 논문에서는 선반입 구간을 고정함으로써 적재비용과 적재시간을 일정한 범위 이하로 유지하면서 시스템 자원의 활용율을 높이는 방법을 제안한다. 그리고 고정 선반입 구간을 사용할 경우 발생하는 상영 실패를 GOP내의 B프레임에 한정하며, Drop모듈을 이용하여 미디어 질 저하를 전체 사용자에게 분산시키는 방법을 제안한다.

  • PDF

Experimental Analysis of Droplet Formation Process for Inkjet Printhead (잉크젯 헤드를 이용한 액적 토출 현상의 실험적 분석)

  • Jo, Y.M.;Park, S.J.
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.163-169
    • /
    • 2010
  • Jetting stability is the most important factors in inkjet printing because printing quality is totally determined by shape of the droplets on the substrate. In order to acquire stable jet, viscosity and dynamic behavior of the ink must be considered. In addition, waveform to drive the inkjet printhead is also to be controlled. In this study, the driving waveform composed of rising time, dwell time and falling time is optimized to obtain a stable jetting using drop watcher system. Also, effect of ink viscosity on jetting is experimentally investigated by changing the temperature of ink cartridge. As a result, jetted drop having uniform velocity is acquired.