• Title/Summary/Keyword: Drop Test

Search Result 1,305, Processing Time 0.032 seconds

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

Board Level Reliability Evaluation for Package on Package

  • Hwang, Tae-Gyeong;Chung, Ji-Young
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2007.04a
    • /
    • pp.37-47
    • /
    • 2007
  • Factor : Structure Metal pad & SMO size Board level TC test : - Large SMO size better Board level Drop test : - Large SMO size better Factor : Structure Substrate thickness Board level TC test : - Thick substrate better Board level Drop test : - Substrate thickness is not a significant factor for drop test Factor : Material Solder alloy Board level TC test : - Not so big differences over Pb-free solder and NiAu, OSP finish Board level Drop test : - Ni/Au+SAC105, CuOSP+LF35 are better Factor : Material Pad finish Board level TC test : - NiAu/NiAu is best Board livel Drop test : - CuOSP is best Factor : Material Underfill Board level TC test - Several underfills (reworkable) are passed TCG x500 cycles Board level Drop test : - Underfill lots have better performance than non-underfill lots Factor : Process Multiple reflow Board level TC test : - Multiple reflow is not a significant actor for TC test Board level Drop test : N/A Factor : Process Peak temp Board level TC test : - Higher peak temperature is worse than STD Board level Drop test : N/A Factor : Process Stack method Board level TC test : - No big difference between pre-stack and SMT stack Board level Drop test : - Flux dipping is better than paste dipping but failure rate is more faster

  • PDF

Effect of Eye Drop Education on Adherence to Glaucoma Medication (점안 지도가 항녹내장 안약의 처방 순응도에 미치는 영향)

  • Park, Kyung-Ji;Song, Hyun Ju;Sohn, Uy Dong
    • YAKHAK HOEJI
    • /
    • v.57 no.2
    • /
    • pp.139-149
    • /
    • 2013
  • Glaucoma is a potentially blinding chronic disease requiring life-long commitment to medical therapy. Failure to adhere to anti-glaucoma treatment may lead to disease progression and visual loss. This study surveyed the adherence to glaucoma eye drop and eye drop instillation technique of glaucoma patients and analyzed the improvement of the adherence and installation technique after patient education for eye drop instillation instructions. Collected responses were statistically analyzed using Kruskal-Wallis test, Mann-Whitney test, Chi-square test, Fisher's exact test, Spearman's correlation coefficient, or one sample proportion test. The survey after patient education for proper eye drop instillation revealed that, even if the patients experienced the adverse effect of their eyes getting dry, they used the eye drop more regularly. They were better at instillation techniques like putting the eye drop inside the eye, and also avoiding applying too much medication or touching their eye with the eye drop bottle. Also, when the patients were divided into groups based on etiologic division, there was difference among groups regarding which category they answered has improved. The result showed improvement in adherence to glaucoma eye drop and eye drop instillation technique after patient education, implicating that patient education is an important aspect of eye care for glaucoma patient and helps them participate in the proper management.

Development and Application of Drop Impact Tester for Aerospace Structures (항공우주구조물 낙하충격시험기 개발 및 응용)

  • Yesol Shin;Hyejin Kim;Juho Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.3
    • /
    • pp.56-64
    • /
    • 2024
  • In this study, a drop impact tester was developed to comprehensively conduct basic testing and academic research on the drop impact characteristics of aerospace structures. A drop tester enables accurate assessment of the dynamic stresses and deformations that occur when an aircraft collides with the ground, thereby enabling the verification of important design factors, such as safety and mechanical strength. The drop tester consists of an electromagnet to attach and drop the test object, a crane to adjust the drop height of the test object, and a drop support structure for vertical drops. Numerical analysis of the drop test object for the test was performed, and basic tests were performed using the drop impact tester. Through the analysis and test results, the structural shape of the landing gear was analyzed, and the behavior of each part was evaluated.

Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System (전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석)

  • Kim, Joo-Rak;Jang, Dong-Uk;Chang, Sang-Hoon;Lee, Young-Heum
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR 제어봉집합체 낙하성능시험)

  • Lee, Young Kyu;Kim, Hoe Woong;Lee, Jae Han;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

Measurement and Analysis of Voltage Drop in Traction Power Supply System (전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석)

  • Kim, Joo-Rak;Lee, Young-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Drop Test for the UAV Landing Gear Performance Verification (무인정찰기 착륙장치 성능입증을 위한 낙하시험)

  • Shin, Jeong-Woo;Lee, Seung-Gyu;Yang, Jin-Yeol;Kim, Sung-Joon;Hwang, In-Hee;Chung, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.250-254
    • /
    • 2011
  • Main role of landing gear is to absorb the energy which is generated by aircraft lanidng and ground maneuvering. Generally, in order to absorb the impact energy during landing, oleo-pneumatic type shock absorber is used for aircraft landing gear. Oleo-pneumatic type shock absorber has a good energy absorbing efficiency and is light in weight because its structure is relatively simple. For the landing gear development, it is necessary to conduct drop test in order to verify shock absorbing performance. In the drop test, first, gas spring curve verification tests are conducted. Then, limit and reserve energy absorption drop tests are performed based on the STANAG 4671. The drop tests results with performance analysis results are presented.

  • PDF

Design & Fabrication for Small Aircraft Landing Gear Drop Test Rig System (소형 항공기 착륙장치 낙하시험 장비 설계 및 제작)

  • Han, Jae-Do;Lee, Young-Shin;Ahn, Oh-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1121-1125
    • /
    • 2008
  • A development of landing gear drop test rig system for a small aircraft was studied and presented in this paper. Hydraulic actuators were considered in order to operate test system automatically and the wire winch system was applied to keep safety of test operators. This rig system was manufactured after checking the structural stability. Friction force measurement and drop velocity evaluation tests were done to confirm the confidence of test system. As a results of evaluation tests, it was confirmed that developed landing gear drop test system was adaptable.

Drop Test of an Oleo-pneumatic Landing Gear (유공압 착륙장치 낙하시험)

  • Kim, Tae-Uk;Lee, Sang-Wook;Shin, Jeong-Woo;Lee, Seung-Kyu;Kim, Sung-Chan;Hwang, In-Hee;Kang, Shin-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1130-1135
    • /
    • 2010
  • The main function of a landing gear is to absorb the impact energy during touchdown. Most landing gear use an oleo-pneumatic shock absorber which essentially consists of an oil damper and a gas spring. The performance of a shock absorber can be estimated by analysis but it should be verified by drop test, which is required by MIL Spec. and FAR. In the drop test, various data such as ground loads, shock absorber pressure, stroke and mass travel are analyzed to validate the shock absorbing efficiency and the mathematical model for analysis. This paper presents the introduction of drop test facility, the test procedure and data evaluation method with real drop test example.