• 제목/요약/키워드: Drop Characteristic

검색결과 282건 처리시간 0.029초

양발 드롭랜딩 시 만성적인 발목 불안정성 유무에 따른 하지주요관절의 역학적 특성 (Biomechanical Characteristic on Lower Extremity with or without Chronic Ankle Instability during Double Leg Drop Landing)

  • Jeon, Kyoungkyu;Park, Jinhee
    • 한국운동역학회지
    • /
    • 제31권2호
    • /
    • pp.113-118
    • /
    • 2021
  • Objective: The purpose of this study was to investigate differences of landing strategy between people with or without chronic ankle instability (CAI) during double-leg drop landing. Method: 34 male adults participated in this study (CAI = 16, Normal = 18). Participants performed double-leg drop landing task on a 30 cm height and 20 cm horizontal distance away from the force plate. Lower Extremities Kinetic and Kinematic data were obtained using 8 motion capture cameras and 2 force plates and loading rate was calculated. Independent samples t-test were used to identify differences between groups. Results: Compared with normal group, CAI group exhibits significantly less hip internal rotation angle (CAI = 1.52±8.12, Normal = 10.63±8.44, p = 0.003), greater knee valgus angle (CAI = -6.78±5.03, Normal = -12.38 ±6.78, p = 0.011), greater ankle eversion moment (CAI = 0.0001±0.02, Normal = -0.03±0.05, p = 0.043), greater loading Rate (CAI = 32.65±15.52, Normal = 18.43±10.87, p = 0.003) on their affected limb during maximum vertical Ground Reaction Force moment. Conclusion: Our results demonstrated that CAI group exhibits compensatory movement to avoid ankle inversion during double-leg drop landing compared with normal group. Further study about how changed kinetic and kinematic affect shock absorption ability and injury risk in participants with CAI is needed.

Pressure drop characteristics of concentric spiral corrugation cryostats for a HTS power cable considering core surface roughness

  • Youngjun Choi;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.19-24
    • /
    • 2023
  • Recently, interest in renewable energy such as solar and wind power has increased as an alternative to fossil fuels. Renewable energy sources such as large wind farms require long-distance power transmission because they are located inland or offshore, far from the city where power is required. High-Temperature Superconducting (HTS) power cables have more than 5 times the transmission capacity and less than one-tenth the transmission loss compared to the existing cables of the same size, enabling large-capacity transmission at low voltage. For commercialization of HTS power cables, unmanned operation and long-distance cooling technology of several kilometers is essential, and pressure drop characteristic is important. The cryostat's spiral corrugation tube is easier to bend, but unlike the round tube, the pressure drop cannot be calculated using the Moody chart. In addition, it is more difficult to predict the pressure drop characteristics due to the irregular surface roughness of the binder wound around the cable core. In this paper, a CFD model of a spiral corrugation tube with a core was designed by referring to the water experiments from previous studies. In the four cases geometry, when the surface roughness of the core was 10mm, most errors were 15% and the maximum errors were 23%. These results will be used as a reference for the design of long-distance HTS power cables.

두 개의 P-플로팅 층을 가지는 새로운 IGBT에 관한 연구 (A Novel IGBT with Double P-floating layers)

  • 이재인;최종찬;양성민;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.14-15
    • /
    • 2009
  • Insulated Gate Bipolar Transistor(IGBTs) are widely used in power device industry. However, to improve the breakdown voltage, IGBTs are suffered from increasing on-state voltage drop due to structural design. In this paper, the new structure is proposed to solve this problem. The proposed structure has double p-floating layer inserted in n-drift layer. The p-floating layers improve the breakdown voltage compared to conventional IGBT without change of other electrical characteristics such as on-state voltage drop and threshold voltage. this is because the p-floating layers expand electric field distribution at blocking state. A electrical characteristic of proposed structure is analyzed by using simulators such as TSUPREM and MEDICI. As a result, on-state voltage drop and threshold voltage are same to a conventional TIGBT, but breakdown voltage is improved to 16%.

  • PDF

전극길이 변화에 따른 실린더 형태 ER밸브의 성능고찰 (Performance Investigation of Cylindrical-Type ER Valves With Different Electrode Length)

  • 전영식
    • 한국생산제조학회지
    • /
    • 제7권6호
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents performance analyses of three types of the cylindrical-type ER(electro-rheo-logical) valves, which have different electrode length and width but same electrode area. Following the composition of silicone oil-based ER fluid, the field-dependent yield stresses are obtained from experimental investigation on the Bingham property of the ER fluid. The ER valve which is dependent on the applied electric field is devised and its theoretical model is derived. On the basis of the pressure-drop analysis, three types of the ER valves are designed and manufactured. After experimentally evaluation field-dependent pressure drops, PI controller is formulated to achieve tracking control on desired pressure drop. The controller is then experimentally implemented and tracking control performance is presented in order to demonstrate superior controllability of the ER valve. In addition, the response characteristic of the ER valve with respect to the excitation frequency of the electric fiedls is provided to show the feasibility of practical application.

  • PDF

ERF를 이용한 유압제어밸브의 특성실험 (Characteristic Experiment of a Hydraulic Control Valve by Using Electro-Rheological Fluid)

  • 김동수;박재범;장성철
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.93-99
    • /
    • 2000
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. The electrical and rheological properties of zeolite based the ER fluids were reported. The electric field dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Using ER fluids, it is possible to directly interface between electric drop and flow rate of the ER fluid was hydraulic control valve measured under application of an electric field. The purpose of the present study is pressure drop measurement of an ER valve by using strain gage. The performance characteristics of the valve system are evalusted in terms of pressrue fixed with respect to the intensity of employed electric fields and flow rates. As a result, it is esperimentally confirmed that pressure control valve using ER fluids applicable to use in hydraulic power systems.

  • PDF

로켓 엔진의 연소 성능 예측 및 시험 (Performance Prediction of Rocket Engine Combustion and Estimation of Experimental Results)

  • 박정;김용욱;김영한;정용갑;조남경;오승협
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.718-724
    • /
    • 2000
  • A model for depicting the rocket engine combustion process is presented and several experiments near a design point are provided with a FOOF type of unlike impinging injector for a propellant combination of Jet A-1 fuel and liquid-oxygen. The model is based on the assumption that the vaporization is the rate-controlling combustion process. The effects of initial drop size and initial drop velocity are systematically shown and discussed. It is seen that in the midst of considered parameters the change of initial drop size is more sensitive to the performance. The proposed model describes qualitative trends of combustion process well despite of its simplicity.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 특성 분석 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;이순명
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.111-115
    • /
    • 2006
  • To clarify the hydraulic and thermal characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flow in the double tube and plate type heat exchanger, experimental studies were performed. The mass flux and Ice fraction of ice slurry were varied from 800 to $3,500 kg/m^2s$(or 7 to 17 kg/min) and from 0 to 25%, respectively. During the experiment, it was found that the measured pressure drop and heat transfer rate increase with the mass flux and ice fraction; however the effect of ice fraction appears not to be significant at high mass flux region. At the region of low mass flux, a sharp increase in the pressure drop and heat transfer rate were observed depends on mass flux.

  • PDF

Experimental study on the effects of stern bulb arrangement on the slamming load

  • Park, Jongyeol;Choi, Ju Hyuck;Lee, Hyun-ho;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.518-530
    • /
    • 2020
  • The present study concerns the stern slamming load of container carriers, with stern bulb arrangement variation. First, a series of wedge drop tests were conducted using simple wedge models with fixed deadrise angles, and tests with the cross-section models of practical container carrier sterns were followed. The deadrise angle of the simple wedge ranged from 0° to 10°. The pressure measurement results of the simple wedge drop tests were distributed between empirical formula and analytic solution, so the experimental setup was validated. In the cases of practical hull cross-sections, the water entry of the bulb prior to that of the transom resulted in characteristic water film generation and delayed pressure peak appearance. The trapped air between the bulbs damped the pressure in the twin skeg hull case, reducing the pressure peak and causing the pressure oscillation during water entry.

중년 여성의 드롭치에 따른 체형 특성 연구 (Characteristics of Somatotype Classified by the Drop Value of Middle-Aged Women)

  • 윤지원;서미아
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.939-946
    • /
    • 2009
  • This study is to classify the shape of the body by means of the drop value of the middle-age women. Drop value is based on the circumstances of the body deciding the dimentions of the clothes. Therefore, the study based on the drop value seems to decided the measurement of the clothes in making mass production of ready made clothes. In order to put measure items on this study of the value on 'The fifth survey of body measure of Korean', select 785 people in middle-aged women aged from 40 to 59. And considering the characteristic of upper-drop and lower-drop, and swelling belly by accumulated fat, selected five items(Bust Circumstance - Waist Circumstance, Hip Circumstance - Waist Circumstance, Hip Circumstance - Bust Circumstance, Waist Circumstance(Omphalion) - Waist Circumstance, Hip Circumstance - Waist Circumstance(Omphalion)). The result of the study is summarized as follows. Type 1, M type of the body showed the distribution of 32.5% and belonged to low body development style. The line of human body is the nearest of the four bodies in middle-age woman out of whole shapes of 4 types and the line of human body is close to middle-age woman. Type 2, X type of the body showed the distribution of 40.8% and the line of human body remarkably showed. Type 3, H type of the body showed the distribution of 12.4% and the line of human body appears least. This group was larger than any other group in having more fat in the belly above the circumstance of the hip than other groups. Type 4, Y type of the body showed the distribution of 14.4%. This type was upper half of body development style, waist was slender, and there was seldom the bend around the circumstance of belly and hip.

  • PDF

A Study on the Tolerance Band of Voltage Drop during Motor Startup for Refineries and Chemical Plants with Isolated Power Systems

  • Shin, Ho-Jeon;Cho, Man-Young;Chun, Hong-Il;Kim, Jin-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.486-493
    • /
    • 2017
  • Refineries and chemical plants with isolated power systems that have a limited power supply are more susceptible to voltage changes from disturbances compared to power systems connected with a power company. Furthermore, most loads in such cases are induction motor loads, and therefore, transient voltage characteristics when starting a high-capacity motor must be examined. In general, high-capacity motors are customized appropriately to the load performance curve by the manufacturer during the construction of an industrial plant. Subsequently, when complying with the voltage drop permitted by international standards during the design process, power supply equipment such as transformers and generators is overdesigned. Therefore, a novel analysis is necessary on standards for startup and constraint voltage drops, as well as on identifying the voltage drop limitations for starting high-capacity motors in refineries and chemical plants with isolated power systems. In this study, field tests on an industrial plant were conducted, and simulations modeled under conditions identical to those of the field test system were performed using the general-purpose program ETAP in order to compare the results.