• Title/Summary/Keyword: Drinking water temperature

Search Result 201, Processing Time 0.023 seconds

The model on Formation of Trihalomethane in Purifying Process of Drinking Water (정수처리긍정에서 소독부산물인 트리할로메탄의 생성모델)

  • 이성식;성낙창;이종팔;박현석;정미은;이상준;윤태경
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.297-300
    • /
    • 2004
  • We have been proposed model equation which is able to predict the trihalomethane producing concentration formation, that is one of byproduct, in the water treatment processes. In proposed model, the effects of trihalomethane factors like chlorine contact time, pH, temperature, TOC and UV-254 are considered. The concentration of the trihalomethane produced is proportion to the contact with chlorine, pH of water, temperature of water TOC and UV-254, respectively. This proposed model could be predicted the formed concentration of trihalomethanes by trihalomethane factors.

Removal of Ammonia Nitrogen and Reduction of THMs in Low Temperature by BAC Pilot Plant (BAC Pilot Plant 를 이용한 겨울철 암모니아성 질소 제거 및 THMs 변화)

  • Kang, Eun-Jo;Seo, Young-Jin;Lee, Won-Kwon;Chun, Pyoung-Hee;Lee, Ji-Hyung;Yoon, Jung-Hyo;Kim, Dong-Youn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.107-114
    • /
    • 1995
  • The raw drinking water quality is getting worse because of the winter drought and the conventional treatment system is'nt suitable to obtain the satisfied quality of water. So, the advanced water system, BAC(Biological Activated Carbon) process is said to be effective to remove dissolved organics and ammonia nitrogen. In our study, the BAC pilot plant using Nak-dong river water is tested in low temperature. Following results are found from the study. The ammonia nitrogen removal rate of BAC system using wood-based carbon (PICABIOL) was 99% in $6^{\circ}C$ temperature. Chlorine dosage in wood-based BAC effluent was reduced to 67% of that in sand filtered wate. It resulted from the removal of ammonia nitrogen. Also, THM formed by chlorine addition in wood-based BAC effluent was decreased to 65% of that in sand filtered water. In the case of dual-filter, the removal efficiency of ammonia nitrogen was increased 30% more than in conventional sand filter. According to this result, the ammonia nitrogen load to BAC system could be lessened by the use of dual-filter.

  • PDF

Analysis of Harmful Cyanobacteria Occurrence Characteristics and Effects of Environmental Factors (덕동호 유해남조류 출현 특성 및 환경요인 영향 분석)

  • Dong-Gyun Hong;Hae-Kyung Park;Yong-jin Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.1
    • /
    • pp.20-29
    • /
    • 2023
  • This study analyzed the relationship between harmful cyanobacterial abundance and environmental factors in order to figure out the causes of the recent increase of cyanobacteria in Lake Dukdong from 2019 to 2021. Lake Dukdong, which is used as a drinking water source for Gyeongju City, has an algae alert system in place. Lake Dukdong has maintained good water quality, but algae alert level 1 (over 1,000 cells/mL) has been issued in recent years. As a result of Pearson correlation analysis (from May to Oct.), the cell density of Microcystis and Aphanizomenon, which form part of the most harmful cyanobacteria genus, were significantly positively correlated with the water temperature and water storage volume. T-test was performed to compare the data from 2016-2018 and 2019-2021 (from May to Oct.). The average density of harmful cyanobacteria cells increased about six-fold from 54 to 344 cells/mL. There were significant differences in water temperature, pH, total nitrogen (TN), total phosphorus (TP), TN/TP ratio, water storage volume, and cyanobacterial cell density. Water temperature increased from 19.2 to 22.8 ℃. TP concentration increased from 0.017 to 0.028 mg/L. The main cause of the recent increase of harmful cyanobacteria in Lake Dukdong is thought to be the increase in water temperature, TP concentration, and water storage volume from 2019 and 2021, resulting in more favorable conditions for cyanobacterial growth.

Disinfection of Water by Ultrasonic Irradiation (초음파 검사에 의한 수중의 살균처리)

  • 손종렬;유병성
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

Changes in Microbiological and Chemical Properties of Natural Water with the Storage Time and Temperature (시판 먹는 샘물의 저장 기간 및 온도에 따른 세균학적 및 화학적 품질 변화)

  • 박신인;이왕규;조윤정
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • This study was carried out to investigate the microbiological and chemical properties of natural water during storage. The water samples were taken at the time of purchase and the opened bottles and unopened bottles stored at the temperature of 4$^{\circ}C$, 18$^{\circ}C$, and 3$0^{\circ}C$. The bacterial content normally rose to 2.06$\times$102 CFU/$m\ell$ for the unopened bottles and 2.91$\times$102 CFU/$m\ell$ for the opened bottles after 2 weeks of storage, and 1.21$\times$102 CFU/$m\ell$ and 2.64$\times$102, respectively, after 24 weeks of storage. The number of viable cells of bacteria peaked more rapidly at the storage temperature of 3$0^{\circ}C$ than 18$^{\circ}C$. But the total samples were found to be negative for coliforms test during the study period. The average range of pH value was from 7.39 to 7.76. The results showed that the nitrates and chlorides satisfied the Korea Drinking Water Quality Standards during the storage period of 24 weeks. However, the undesirable changes of the taste and odor were detected within 2 weeks and 3 weeks, respectively.

  • PDF

Concentration of Formaldehyde and Acetaldehyde depending on the Time of Storage into Mineral Water (먹는샘물의 보관 기간에 따른 formaldehyde 및 acetaldehyde의 농도 변화)

  • Lee, Youn-Hee;Lee, Jun-Bae;Park, Ju-Hyun;Choi, Ja-Yoon;Ahn, Kyung-Hee;Ahn, Hye-Sil;Kwon, Oh-Sang;Kim, Tae-Seung;Han, Jin-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2011
  • BACKGROUND: According to Korean regulations, bottled waters (BWs) can not be treated with chemical disinfectants like chlorine, so UV and ozone disinfection is applied. During the past several years, chemicals were detected in some BWs, and the public was concerned about the safety of BWs. METHODS AND RESULTS: Mineral waters were stored for 180 days at $25^{\circ}C$ and $50^{\circ}C$, tested acetaldehyde and formaldehyde by HPLC. When mineral waters were put in a PET bottles, the formaldehyde level ranged from 5 to $66{\mu}g/L$ during 180 days at $50^{\circ}C$. While the acetaldehyde level ranged from 31 to $221{\mu}g/L$, it was low than $16{\mu}g/L$ in glass bottle. CONCLUSION(s): This result showed that formaldehyde and acetaldehyde were detected higher in PET bottles than glass bottles, these also increased depending on the time of storage. Concentration of formaldehyde and acetaldehyde could be significantly influenced by the time of storage and temperature.

A Study on Dissolve and Remove Analysis of Organic Chemicals Using a Mixed Method of Advanced Oxidation and Micro Filtering - Water Drinking Point - (고도산화와 정밀여과의 혼성공법을 이용한 유기화학물질의 분해 및 제거분석에 관한 연구 - 먹는 물을 중심으로 -)

  • An, Tai-Young;Jun, Sang-Ho;Ahn, Tae-Seok;Han, Mi-Ae;Hur, Jang-Hyun;Pak, Mi-Young
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.99-111
    • /
    • 2007
  • It is impossible to remove toxic organic substances that are recognized as a cancer caused suspicious element in drinking water using the conventional water purification method. This study introduces groundwater into a reaction chamber as an effective amount of water to process this water using a mixed method of AOP oxidation and M/F membrane and purifies it as a desirable level by artificially mixing such toxic substances in order to effectively process the water. Based on this fact, this study configures an optimal operation condition. The VOCs existed in toxic substances was investigated as a term of phenol and toluene, and agricultural chemicals were also investigated as a term of parathion, diazinon and carbaryl. The experiment applied in this study was performed using a single and composite soolution. In the operation condition applied to fully dissolve and remove such substances, the amount of $H_2O_2$ injected in the process was 150 mL of a fixed quantity, the value of pH was configured as $5.5{\sim}6.0$, the temperature was controlled as a range of $12{\sim}16^{\circ}C$, the dissolved amount of ozone was applied more than 5.0 mg/L, the reaction time was determined as an optimal condition, such as $30{\sim}40$ minutes, and the segregation membrane in the same reactor was determined for acquire water drinking of large quantity using a pore size of $0.45{\mu}m$ M/F membrane.

Hydrogeochemistry of Supply Water in the Daedeok Campus of Chungnam National University, Korea (충남대학교 대덕캠퍼스내 상수도 물의 수리지구화학적 특성)

  • 이찬희
    • Economic and Environmental Geology
    • /
    • v.33 no.3
    • /
    • pp.181-193
    • /
    • 2000
  • This study was undertaken to evaluate the drinking water quality based on physicochemical properties and chemical compositions of the supply water in the Daedeok Campus, and to verify the analytical reliabilities of ICP-MS and IC equipped in the Central Research Facilities at Chungnam National University , Korea. The supply water belongs to $Ca^{2+}-({HCO_3}^-+{SO_4}^{2-})$type, whereas the original water from the Daecheong lake belongs to $(Ca^{2+}-(Mg^{2+})-{HCO_3}^-$ type. Generally, temperature (14.1$^{\circ}C$), pH (6.95), Eh (0 mV), electrical conductivity (117${\mu}$S/cm) and TDS (86.975mg/l) of supply water were higher than those of original lake water . Results using WATEQ4F revealed that potentially toxic ions of the supply water might exist mainly as free metals ($M^{2+}$) and a small amount as ${CO_3}^{2-}$ and $OH^-$ complexes. Also, the water composition belongs to the kaolinite field. Calculated average enrichment indies of the supply water normalized to lake water for anions, mamor cations, toxic cations and total ions are 1.05 , 1.56, 13.05 and 1.17 , respectively. Those values of the ground water in the Daedeok Campus showed 1.71, 4.78, 5.71 and 2.49 , respectively. However , contents of all constituents of these water are within the drinking water standard. All samples were filtered before the chemical analysis. Pale yellow or yellowish brown colored materials of colloidal particles coated the filter paper to thickness of 0.02 to 0.2mm. these are mainly Fe-Cy-Zn compounds with traces of Ni and Pb, the net weights of which compounds range from 0.01to 3.20mg/l. Most elements did not show any conceivable filtering effect of Cu, Fe and Zn. Especially, mean concentration of total Fe decreased considerably from 168.52${\mu}g$/lto 42.58${\mu}g$/l by filtering .

  • PDF

A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (초속경화(初速硬化) 폴리우레아수지 도막방수재(途膜防水材)의 방수(防水)·방식(防蝕) 성능평가(性能評價)에 관한 연구(硏究))

  • Cho, Chan-Haeng;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, inner chemical performance, drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF

A Study on Waterproofing Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (뿜칠형 초속경화 폴리우레아수지 도막방수재의 성능평가에 관한 연구)

  • Oh, Sang-Keun;Kim, Su-Ryun;Lee, Sung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.1
    • /
    • pp.131-138
    • /
    • 2002
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, Inner chemical performance. drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.