• 제목/요약/키워드: Drinking water quality standard

검색결과 143건 처리시간 0.039초

대전지역 지하수에 함유된 우라늄 및 라돈의 함량 (Abundances of Uranium and Radon in Groundwater of Taejeon Area)

  • 한정희;박계헌
    • 자원환경지질
    • /
    • 제29권5호
    • /
    • pp.589-595
    • /
    • 1996
  • The concentration of radioactive elements was measured from the groundwater samples of Taejeon Area. U and Rn concentrations of very high level were detected from many places, especially around Yusung. These levels are much higher than the concentration standards for the drinking water proposed by the United States Environmental Protection Agency. However, in Korea, there are no standard levels for the radioactive elements in drinking water yet. We think that it is necessary to provide such standards as soon as possible, and that the determination of radioactive elements in groundwater should be included in the routine analysis items for the drinking water quality, because many people currently use such relatively high level radioactive groundwater as their drinking water, especially around Yusung area.

  • PDF

정수기용 입상활성탄소 필터의 흡착특성에 관한 고찰 (Adsorption Characteristics of Granular Activated Carbon Filter Used for Drinking Water Purifier)

  • 백영만;박제철;김형진
    • 한국환경과학회지
    • /
    • 제17권8호
    • /
    • pp.899-905
    • /
    • 2008
  • Quality test for activated carbon(AC) filter used for drinking water purifier is now an obligatory test and the standard material for valid purifying amount in water purifier performance test has been changed from residual chlorine to chloroform according to the notice of Ministry of Environment in 2006. Therefore, this study aimed to compare the ingredients of AC filters by confirming chloroform removal rate of AC filter and conducting 4 adsorption tests (Iodine, methylene blue decolorization, phenol value, ADS value) for AC filters provided by manufacturers. With water pressure of $1kgf/cm^2$, 1,500 liters of prepared inflow went through to check chloroform removal rate. As a result, product with removal rate of below 60% from all products. On the other hand, 4 adsorption tests were conducted for filters in the market and filters from manufacturers. None of the products satisfied all 4 tests. In particular, they showed great shortage to the standard in phenol value and ADS value test. However, manufacturers' filter showed much better performance than filters in the market. Also, the result of valid purifying amount test for each of five products of appropriate product and inappropriate product based on filter quality test showed average 4,440 liters for appropriate product and average 2,620 liters for inappropriate product. According to the result, it is shown that the filter with good adsorption also had good chloroform removal efficiency and adsorption efficiency. Therefore, it is expected that customers can screen good quality product through obligatory conduct of filter quality test. However, it is considered that complementation in system is required for future inspection.

충청남도 음용지하수 수질의 특성 (The Characteristics of Drinking Groundwater Quality in Chung Cheong Nam Do)

  • 김흥락;한운수;박혜숙
    • 한국환경과학회지
    • /
    • 제11권7호
    • /
    • pp.721-727
    • /
    • 2002
  • The characteristics of drinking groundwater quality at Chung Cheong Nam Do was analyzed by investigating the 3,086 groundwater data which were carried out the water quality inspection from Jan. 1998 to Dec. 1998. It was found that all the mean concentration of items was not over the drinking water quality standard except Zn at Yeongee area. The highest mean concentration of nitrate was $8.2 mg/{\ell}$ at Hongsung area. And the mean concentrations of nitrate and ammonium at Sucheon, Yesan, Yeongee were relatively higher. It was considered that the groundwater of that area was contaminated by breeding livestock as farm pollutants. The mean concentrations of chloride, hardness and evaporation residual at coastal regions were higher than inland regions. Especially the mean concentration of chloride was 2.5 times higher. It was considered that the groundwater at coastal regions was affected by seawater. It was found that the correlation between Fe and Mn was relatively high(r=0.776) and the correlation between hardness and evaporation residual was very high(r=0.983). The rainfall series and detection rate of E-coli had the hydrologic persistence. The correlation between the detection rate and rainfall series over 150 mm was very high (r=0.9146). Therefore it is surely required to control the groundwater sanitation in the rainy season.

생물막 여과에 의한 지하수중 질산성 질소의 제거 (Removing Nitrate from Groundwater by Biofilm Filtration)

  • 이용두;고인범
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.83-89
    • /
    • 1998
  • The drinking water supply in Cheju entirely depends on the ground water and recently the polluted ground water bores are increasing. In 1993 Cheju Province Health-Environment Institute reported that the ground water quality of 26 of 98 bores under the drinking water quality standard. Therefore there are many investigation in the needs of the nitrate removal in the drinking water in the regin with no alternative water resources. In this study, the following results are obtained to remove the nitrate in biofilm filtration process in which uses ethanol as external carbon source. Over 90% of nitrate is removed after 10 days of experiment. The nitrate removal rate on filtration velocity is about 100% at 50m/day and 100m/day, and about 56% at 200m/day. The removal rate is reduced in 27% at 400m/day. Using ethanol as the external carbon source, denitrification kinetic is 1st-order. Denitrification constant k is 8.004($hr^{-1}$). The amount of the denitrificated-Nitrogen is increased as the contact time increased. Deoxydation rate constant ${\gamma}$ is 11.895($hr^{-1}$). 0.968g of ethanol(as TOC) is needed to remove 1g of nitrate and 0.291g is required to remove 1g of dissolved oxygen.

  • PDF

캄보디아 쁘로얍 지역과 랭뜰 지역 거주민의 먹는물 현황 (Status of Drinking Water in Pproyap and Langthle, Cambodia)

  • 김연권;김성필;채선하
    • 환경영향평가
    • /
    • 제25권5호
    • /
    • pp.357-368
    • /
    • 2016
  • 캄보디아는 동남아시아 지역에서 대표적인 저개발 국가이다. 수자원의 관점에서 캄보디아는 풍부한 수량을 갖고 있지만, 농촌지역에서는 안전하지 않은 식수와 처리되지 않은 분뇨에 의하여 공중 보건의 문제가 이어지고 있다. 본 연구는 캄보디아 지역에서의 물 원조 프로그램을 위한 신전략수립과 준비를 위해 현지조사, 검토 및 농촌지역에서의 물 오염현황분석, 그리고 해당지역의 물 순환을 분석하였다. 조사 대상지역은 푸르사트주에 있는 쁘로얍과 랭뜰을 조사 대상지로 정하였다. 연구대상 농촌지역의 사람들은 식수전용 웅덩이, 빗물 항아리, 관리되지 않은 우물물 등 지표수에 의존하고 있었다. 분석은 분원성 미생물(TTC)과 일반항목으로 크게 두 가지로 하였으며, 대상지역에서 채수한 시료들을 분석/평가하였다. TTC는 수인성 배설물 오염의 세균 지표인데 26개의 시료중 단 한개만이 WHO가 규정한 TTC 허용한계인 불검출/100 mL의 기준을 충족시켰다.

주암호 유역의 강우사상에 따른 오염물질의 유출특성 (A Study of Comparison of outflow characteristics of pollutants by rainfall event of forest area near Juam lake basin)

  • 김남종;신대윤
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.87-104
    • /
    • 2007
  • The objective of this study is to estimate the load of pollutants caused from the forest area among non-point pollutants within the Juam lake. The surveyed forest area was classified into broad-leaved, conifer, mixed and herbage area by forest tree type. Water quality and flux were investigated under rainfall and non-rainfall, respectively. Then, pollutant loading was evaluated by using the values of unit pollutant loading factor of each point and area of forest zone. Water quality analysis results of runoff by forest tree types were as follows. - Annual BOD, $COD_{Mn}\;and\;COD_{Cr}$ concentration of runoff in conifer area was high, and particle and biological recalcitrant compounds were flowed highly. - SS, T-N and T-P concentration was high in runoff from broad-leaved area, and biological degradable compounds was flowed. - Water quality of water from valley was maintained good under non-rainfall and could be utilized as fresh drinking water. Through water quality standard investigation, a countermeasure establishment was necessary to secure a good quality of drinking water - BOD, $COD_{Mn},\;and\;COD_{Cr}$ concentration of Bo-sung river was higher 1.5 times than other 2 streams, and because of high T-N, and T-P concentration in Songgwang stream, the management for this was necessary.

정수장 슬러지 폭기를 통한 방류수 수질 개선 (Improvement of effluent water quality by sludge aeration at the conventional drinking water treatment plant)

  • 최일경;신창수;백인호;임재철;정찬우;이성진;박정욱
    • 상하수도학회지
    • /
    • 제28권2호
    • /
    • pp.249-255
    • /
    • 2014
  • So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.

시흥정수장 막여과시설 시범운영 (A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant)

  • 김한승;김충환;김학철;윤재경;안효원
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Workshop
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

학교음용수 관리 및 이용실태 (A Study on the Management & Utilization of School Drinking Water)

  • 홍정화;박영수
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제1권2호
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

임진강수계의 수질조사 및 개선방안 (A Survey of Water Quality and Improvement Measure of Imjin-River)

  • 김형진;백영석;이준석
    • 환경위생공학
    • /
    • 제10권1호
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF