• Title/Summary/Keyword: Drainage Facilities

Search Result 247, Processing Time 0.041 seconds

Development of Urban Flood Analysis Model Adopting the Unstructured Computational Grid (비정형격자기반 도시침수해석모형 개발)

  • Lee, Chang Hee;Han, Kun Yeun;Kim, Ji Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.511-517
    • /
    • 2006
  • Flood damage is one of the most important and influential natural disaster which has an effect on human beings. Local concentrated heavy rainfall in urban area yields flood damage increase due to insufficient capacity of drainage system. When the excessive flood occurs in urban area, it yields huge property losses of public facilities involving roadway inundation to paralyze industrial and transportation system of the city. To prevent such flood damages in urban area, it is necessary to develop adequate inundation analysis model which can consider complicated geometry of urban area and artificial drainage system simultaneously. In this study, an urban flood analysis model adopting the unstructured computational grid was developed to simulate the urban flood characteristics such as inundation area, depth and integrated with subsurface drainage network systems. By the result, we can make use of these presented method to find a flood hazard area and to make a flodd evacuation map. The model can also establish flood-mitigation measures as a part of the decision support system for flood control authority.

Varied Flow Analysis for Linear Drainage Channels (선형 배수로에 대한 부등류 해석)

  • Ku, Hye-Jin;Jun, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.773-784
    • /
    • 2008
  • The present study was carried out to examine flow properties in linear drainage channels such as road surface drainage facilities. The finite difference formulation for the varied flow analysis was solved for flow profiles in the channels. Starting the first step at the control section, the Newton-Raphson method was applied for producing numerical solutions of the equation. We considered two types of linear drainage channels, a channel with one outlet at downstream end and a channel with two outlets at both ends. Moreover, the flow analysis for various channel slopes was performed. However, we considered channels with the two outlets of slopes satisfying the condition that the both ends are the control section. The maximum of those slopes was decided from the relation between the channel slope and the location of control section. The flow of a channel with one outlet was calculated upward and downward from the control section existing in channel or upward from the control section at downstream end. The flow of a channel with two outlets at both ends were calculated for upstream and downstream channel segments divided by the water dividend, respectively and the flow analysis was completed when the water depth at the water dividend calculated from upstream end was equal to that calculated from downstream end. If the slope was larger than the critical slope, the channel with two outlets was likely to behave like the channel with one outlet. The maximum water depth was investigated and compared with that calculated additionally from the uniform flow analysis. The uniform flow analysis was likely to lead a excessive design of a drainage channel with mild slope.

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas (장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정)

  • Joo, Jingul;Yoo, Doguen;Kim, Joonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.841-847
    • /
    • 2011
  • In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.

The Prototype and Structure of the Water Supply and Drainage System of the Wolji Pond During the Unified Silla Period (통일신라시대 월지(月池) 입·출수 체계의 원형과 구조)

  • Kim, Hyung-suk;Sim, Woo-kyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.124-141
    • /
    • 2019
  • This research explored the relationship between the water quality issue of Wolji Pond (Anapji Pond) with the maintenance of the channel flow circulation system. The water supply and drainage system closely related to the circulation system of pond has been reviewed, rather than the existing water supply and drainage system that has been analyzed in previous studies. As a result of reviewing the water supply system, it has been learned that the water supply system on the southeastern shore of Wolji Pond, being the current water supply hole, has been connected to the east side garden facility (landscaping stone, curved waterway, storage facility of water) between the north and south fence and the waterway. This separate facility group seems to have been a subject of the investigation of the eastern side of Wolji Pond, with the landscaping stones having been identified in the 1920's survey drawings. The water supply facility on the southeastern shore, being the suspected water supply hole, seems to have some connection with the granite waterway remaining on the building site of Imhaejeon (臨海殿) on the southern side of Wolji Pond. It is inferred that it provides clean water, seeing that the slope towards the southwestern shore of Wolji Pond becomes lower, the landscaping stones have been placed in the filter area, and it is present in the 1920's survey drawings and the water supply hole survey drawing of 1975. The water drainage facility on the northern shore is composed of five stages. The functions of the wooden waterway and the rectangular stone water catchment facility seem not to be only for the water drainage of Wolji Pond. In light of the points that there are wood plugs in the wooden waterway and that there is a water catchment facility in the final stage, it is judged that the water of Balcheon Stream (撥川) may be charged in reverse according to this setup. Namely, the water could enter and exit in either direction in the water drainage facility on the northern shore It also seems that the supply to the wooden waterway could be opened and shut through the water catchment facility of rectangular stone group as well. The water drainage facility on the western shore is very similar to the water drainage facility on the northern shore, so it is difficult to avoid the belief that it existed during the Silla Dynasty, or it has been produced by imitating the water drainage facility on the northern shore at some future point in time. It seems to have functioned as the water drainage facility for the supply of agricultural water during the Joseon Dynasty. The water supply and drainage facilities in Wolji Pond have been understood as a systematized distribution network that has been intertwined organically with the facility of Donggung Palace, which was the center of the Silla capital. Water has been supplied to each facility group, including Wolji Pond, through this structure; it includes the drainage system connecting to the Namcheon River (南川) through the Balcheon Stream, which was an important canal of the capital center.

A Study on Risk Evaluation Method of Ground Subsidence around Sewer (하수관로 주변 도로함몰 위험도 평가 방법에 관한 연구)

  • Kim, Jinyoung;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.7
    • /
    • pp.13-18
    • /
    • 2018
  • Recently, road subsidence has been increasing in urban areas, threatening the safety of citizens. In the lower part of the road, various road facilities such as water supply and drainage pipelines and telecommunication facilities are buried, and the deterioration of the facilities causes the road subsidence. In particular, in the case of old sewer pipes which are attracting attention as a main cause of road subsidence, the management of sewer pipe replacement, repair and reinforcement is being performed depending on the burial year. Therefore, in this study, we tried to suggest a reliable road subsidence risk assessment method considering various sewer specifications and surrounding environment information and CCTV exploration result and GPR exploration result.

A Survey of the Kitchen Facilities and Present Meal Situation in the Korean big cities (한국 대도시 가정의 부엌설비 및 조리기구에 관한 실태조사 제I보 : 부엌설비 및 식사현황에 관하여)

  • Kim, Yong-In;Kim, Ki-Sook
    • Korean journal of food and cookery science
    • /
    • v.6 no.1
    • /
    • pp.53-60
    • /
    • 1990
  • This survey was performed to investigate the kitchen facilities and present meal situation in the four Korean big cities; Seoul, Pusan, Kwangju and Taejon. The results are as follows; 1. The kitchen facilities. The number of families with old-fashioned kitchen forms a percentage of 10.8. The kitchen floor consists mainly of polyvinyl chloride materials such as monoryum and vinyl. Gas fuel is mostly used for home cooking. The families equipped waterworks and drainage system in the kitchen cover 92.6% and 85.7% respectively. 2. The present meal situation. Most of the housewives do the cooking for themselves (94.4%) and it is desirable for the health and nutrition of the whole family. The number of families that use the dining kitchen for daily meals covers 53.4%. All the family have their dinner together at most once a week. The instant foods are used frequently in the family whose housewife has a job and the family with high income.

  • PDF

GIS-based Urban Flood Inundation Analysis Model Considering Building Effect (건물영향을 고려한 GIS기반 도시침수해석 모형)

  • Lee, Chang-Hee;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.3
    • /
    • pp.223-236
    • /
    • 2007
  • Recently in urban area flood damages increase due to local concentrated heavy rainfall. Even in the cities where stormwater drainage systems are relatively well established flood damage still occurs because of the capacity limitations of the existing stormwater drainage systems. When the flood exceeds the capacity limitation of the urban storm sewer system, it yields huge property losses of public facilities involving roadway inundation to paralyze industrial and transportation system of the city. To prevent such flood damages in urban area, it is necessary to develop adequate inundation analysis model which can consider complicated geometry of urban area and artificial drainage system simultaneously. The Dual-Drainage model used in this study is the urban inundation analysis model which combines SWMM with DEM based 2-dimensional surface flood inundation model. In this study, the dual drainage model has been modified to consider the effect of complex buildings in urban area. Through the simulation of time variable inundation process, it is possible to identify inundation alert locations as well as to establish emergency action plan for the residencial area vulnerable to flood inundation.

Preference Analysis between Two Administrator Groups on Forest Road Facilities (임도시설에 관한 관리자 집단 간의 의식성향 분석)

  • Ji, Byoung Yun;Kweon, Hyeong-keun;Hwang, Jin Seong;Jung, Do Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.449-455
    • /
    • 2016
  • This study was conducted to provide the basic policy information for systematic forest road planning and maintenance management by surveying two different administrator groups. The survey results showed that the high priorities of forest road planning were silviculture, disaster prevention, and timber harvesting, and main forest road type was preferred for future use. Also 92.9% of the respondents expressed difficulties due to insufficient manpower and budget. The expected damage types due to forest road construction were threat-to-life by slope failure and dispute on crossing private land. The current main maintenance tasks on forest roads included drainage and road surface maintenance works. Main forest road facilities that should be needed after the construction were installation of additional drainage structures, and slope revegetation and stabilization.