• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.024 seconds

Evaluating pollution origins of runoff in urban area by stormwater (강우시 도시지역 강우 유출수 오염부하 기원평가)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.930-934
    • /
    • 2006
  • In this study, we conducted water-quality analysis of wastewater and in-situ flow measurement using automatic flow rate measuring instrument to identify characteristics of wastewater in urban areas, and collected samples in gutter fur storm water drain, rainfall bucket, and aqueduct of pipe from roof, and outfalls of basins to examine the contribution by pollution origins such as base wastewater, atmospheric washing, runoff by roof surface, runoff by road surface, erosion of sewer sediment. In the result, the concentration of pollutants reached peak in the beginning of rainfall due to first flush, was 3 to 10 times higher than average concentration of dry period, and was lower than that of dry period due to dilution of storm water. In the analysis of the contribution by pollution origins, the ratio of load by sewer sediment resuspension to the total pollution load was 54.6% fer COD, and 73.3% fur SS. Accordingly, we can reduce the total pollutant load by periodical dredging and washing of sewer sediment, and control the loadings by overflow of combined sewer overflows.

  • PDF

Risk Factors of Tissue-Expander Infection in Breast Reconstruction (유방재건술에서 조직확장기 감염의 위험인자)

  • Han, Sung-Bum;Lee, Dong-Won;Lew, Dae-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.621-626
    • /
    • 2011
  • Purpose: Implant-based breast reconstruction has multiple advantages such as decreased morbidity, shorter operative time and faster recovery. However, postoperative infection with tissue expander increases medical cost and causes a delay in concurrent antineoplastic treatment. To reduce tissue expander infection, it is important to identify related risk factors and minimize them when possible. Methods: A retrospective review of patient records in a single breast cancer center was performed. Eighty-six tissue expanders were placed in 80 women for postmastectomy breast reconstruction. Variables including patients'age, body mass index (BMI), preoperative breast volume, operation time, drain indwelling time, postoperative seroma/hematoma formation, chemotherapy, and radiation therapy were evaluated. Infection was defined as the status that shows any symptom of local inflammation and identification of pathogens. Representative values were compared through Student's t-test and univariate and multivariate analyses. Results: We examined 86 postmastectomy tissueexpanders which were placed between June 2004 and April 2010. Seven cases of tissue expander infection (8.1%) were identified. The infected tissue expander was removed in three of the cases. The relationship between BMI, and preoperative breast volume and that between infection and non-infection groups were significant ($p$ <0.05). Univariate analysis showed significant association between BMI ($p$=0.023) and preoperative breast volume ($p$=0.037). Multivariate analysis revealed that BMI and preoperative breast volume were independent variables regarding tissue expander infection. Conclusion: Certain characteristics of implant-based breast reconstruction patients increase infection rate of tissue expander. These risk factors should be monitored and evaluated before surgeries for more successful outcome.

A Study on the Characteristics of Z-Trap and Improvement of Maintenance Ability in the Sewage Bay (오수받이 내 Z-트랩 특성 및 유지관리 능력 향상에 관한 연구)

  • Kim, Yong-Cheol;Lee, Chang-Woo
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.450-458
    • /
    • 2019
  • Purpose: The purpose of this study is to develop a new sewage bay that has removed its previous problems and verify the excellence of the maintainability of the new sewage bay. Method: The fluid characteristics in the developed sewage bay was analysed with computer simulation tool(COMSOL MultiphysicsTM ver. 3.2 ; COMSOL) and clarified the problems of the existing sewage bay. In addition, the durability of the newly developed sewage bay was verified by the long-term usability testing. Results: As a result of the simulation of a blocked drainage trap, an whirlpool and blockage did not occurred at the flow rate of 0.6m/sec, and we verified that switch device of drain trap was in good condition durably with 6 months long-term usability test. Conclusion: In this study, a newly advanced sewage bay was developed that solved the problems of the existing sewage bay structure. With the fluid simulation and the long-term usability tests, the excellence of the maintenance ability of the newly developed sewage bay was proved.

Meshed Acellular Dermal Matrix for Two-Staged Prepectoral Breast Reconstruction: An Institutional Experience

  • Luo, Jessica;Willis, Rhett N. Jr;Ohlsen, Suzanna M.;Piccinin, Meghan;Moores, Neal;Kwok, Alvin C.;Agarwal, Jayant P.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.166-173
    • /
    • 2022
  • The introduction of acellular dermal matrix (ADM) to breast reconstruction has allowed surgeons to reexplore the prepectoral implant placement technique in postmastectomy breast reconstruction. Our institution adopted a novel approach using meshed ADM to lessen the financial burden of increased ADM utilization with the prepectoral breast reconstruction. This is a retrospective, single-center review of two-stage prepectoral breast reconstruction using meshed human-derived ADM for anterior prosthesis coverage. Patient demographics, oncologic data, perioperative characteristics, and complications were examined and reported as means with standard deviations. Cost-saving with the meshed technique was evaluated. Forty-eight patients (72 breasts) with a mean age of 48.5 ± 15.0 years (range 26-70 years) were included in the study. The mean follow-up time was 13.2 ± 4.4 months (range 4.1-25.8 months). Nineteen breasts (24.6%) experienced complications, with seromas being the most common complication (12.5%, n = 9). Expander removal and reoperation occurred at a rate of 8.3 and 9.7%, respectively. The average time to drain removal was 18.8 ± 6.6 days (range 8-32 days). Meshed ADM provided an average cost savings of $6,601 for unilateral and $13,202 for bilateral reconstructions. Our study found that human-derived meshed ADM can be safely used in two-staged prepectoral tissue expander-based breast reconstruction and can result in significant cost savings.

AI based complex sensor application study for energy management in WTP (정수장에서의 에너지 관리를 위한 AI 기반 복합센서 적용 연구)

  • Hong, Sung-Taek;An, Sang-Byung;Kim, Kuk-Il;Sung, Min-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.322-323
    • /
    • 2022
  • The most necessary thing for the optimal operation of a water purification plant is to accurately predict the pattern and amount of tap water used by consumers. The required amount of tap water should be delivered to the drain using a pump and stored, and the required flow rate should be supplied in a timely manner using the minimum amount of electrical energy. The short-term demand forecasting required from the point of view of energy optimization operation among water purification plant volume predictions has been made in consideration of seasons, major periods, and regional characteristics using time series analysis, regression analysis, and neural network algorithms. In this paper, we analyzed energy management methods through AI-based complex sensor applicability analysis such as LSTM (Long Short-Term Memory) and GRU (Gated Recurrent Units), which are types of cyclic neural networks.

  • PDF

Characterization of Composite Ground Reinforced with Recycled-Aggregate Porous Concrete Pile (RAPP) (순환골재 다공질 콘크리트말뚝(RAPP)에 의해 보강된 복합지반의 거동 특성)

  • You, Seung-Kyong;Kim, Se-Won;Lee, Chul-Ho;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.117-130
    • /
    • 2009
  • In this paper, a series of laboratory chamber tests were carried out to evaluate the applicability of a porous concrete pile fabricated with recycled aggregates (RAPP) for the soft ground improvement. While performing the laboratory chamber tests for the RAPP, the surface settlement, excess pore pressure and vertical stress distribution with time were compared with those of SCP provided by You (2003) under the same experimental condition. In addition, the experimental results were compared with the numerical simulation using ABAQUS in this study. The results show that the settlement reduction is significantly enhanced due to the stress-sharing mechanism between the RAPP and soil formation by stress concentration on the RAPP. Furthermore, the comparison of consolidation rate shows that the RAPP can accelerate consolidation as well, which behaves as a vertical drain.

Evaluation of Spatial Distribution of Consolidation Settlement of Songdo Marine Clay by Probabilistic Method (확률론적 방법에 의한 인천송도지반 압밀침하량의 공간적 분포 평가)

  • Kim, Dong-Hee;Choi, Young-Min;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.9
    • /
    • pp.15-24
    • /
    • 2010
  • Because the thickness and depth of consolidation layer vary at every location, the consolidation settlement and time have to be evaluated spatially. Also, for a rational evaluation of the uncertainty of the spatial distribution of consolidation settlement and time, it is necessary to adopt a probabilistic method. In this study, mean and standard deviation of consolidation settlement and time of whole analysis region are evaluated by using the spatial distribution of consolidation layer which is estimated from ordinary kriging and statistics of soil properties. Using these results and probabilistic method, the area that needs adopting the prefabricated vertical drain as well as raising the ground level for balancing the final design ground level is determined. It is observed that such areas are influenced by the variability of soil properties. The design procedure and method presented in this paper can be used in the decision making process for a geotechnical engineering design.

Assessment of Meningeal Lymphatics in the Parasagittal Dural Space: A Prospective Feasibility Study Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging

  • Bio Joo;Mina Park;Sung Jun Ahn;Sang Hyun Suh
    • Korean Journal of Radiology
    • /
    • v.24 no.5
    • /
    • pp.444-453
    • /
    • 2023
  • Objective: Meningeal lymphatic vessels are predominantly located in the parasagittal dural space (PSD); these vessels drain interstitial fluids out of the brain and contribute to the glymphatic system. We aimed to investigate the ability of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in assessing the dynamic changes in the meningeal lymphatic vessels in PSD. Materials and Methods: Eighteen participants (26-71 years; male:female, 10:8), without neurological or psychiatric diseases, were prospectively enrolled and underwent DCE-MRI. Three regions of interests (ROIs) were placed on the PSD, superior sagittal sinus (SSS), and cortical vein. Early and delayed enhancement patterns and six kinetic curve-derived parameters were obtained and compared between the three ROIs. Moreover, the participants were grouped into the young (< 65 years; n = 9) or older (≥ 65 years; n = 9) groups. Enhancement patterns and kinetic curve-derived parameters in the PSD were compared between the two groups. Results: The PSD showed different enhancement patterns than the SSS and cortical veins (P < 0.001 and P < 0.001, respectively) in the early and delayed phases. The PSD showed slow early enhancement and a delayed wash-out pattern. The six kinetic curve-derived parameters of PSD was significantly different than that of the SSS and cortical vein. The PSD washout rate of older participants was significantly lower (median, 0.09; interquartile range [IQR], 0.01-0.15) than that of younger participants (median, 0.32; IQR, 0.07-0.45) (P = 0.040). Conclusion: This study shows that the dynamic changes of meningeal lymphatic vessels in PSD can be assessed with DCE-MRI, and the results are different from those of the venous structures. Our finding that delayed wash-out was more pronounced in the PSD of older participants suggests that aging may disturb the meningeal lymphatic drainage.

Efficacy of the omental roll-up technique in pancreaticojejunostomy to prevent postoperative pancreatic fistula after pancreaticoduodenectomy

  • Sisira Jayaratnam;Cherring Tandup;Yashwant Raj Sakaray;Kailash Chand Kurdia;Ashish Gupta;Lileswar Kaman
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.3
    • /
    • pp.358-363
    • /
    • 2024
  • Backgrounds/Aims: Pancreaticoduodenectomy (PD) is being performed more frequently. A pancreaticojejunostomy (PJ) leak is the major determinant of patient outcomes. An omental flap around PJ might improve postoperative outcomes. Methods: A prospective randomized controlled trial was planned at PGIMER, Chandigarh. Fifty-eight patients meeting the criteria were included in the study. Group A underwent PD with omental roll-up and group B underwent standard PD. Results: The mean age of patients in group A was 57.1 ± 14.3 years and 51.2 ± 10.7 in group B. Jaundice (p = 0.667), abdominal pain (p = 0.69), and co-morbidities were equal among the groups. The body mass index of patients in group B was higher at 24.3 ± 5.4 kg/m2 (p = 0.03). The common bile duct diameter (12.6 ± 5.3 mm vs. 17.2 ± 10.3 mm, p = 0.13) and the pancreatic duct diameter (4.06 ± 2.01 mm vs. 4.60 ± 2.43 mm, p = 0.91) were comparable. The intraoperative blood loss (mL) was significantly higher in group B (233.33 ± 9.57 vs. 343.33 ± 177.14, p = 0.04). Drain fluid amylase levels on postoperative day (POD) 1 (p = 0.97) and POD3 (p = 0.92) were comparable. The rate of postoperative pancreatic fistula (POPF) grade A (p ≥ 0.99) and grade B (p = 0.54) were comparable. The mean postoperative length of stay among was similar (p = 0.89). Conclusions: An omental wrap can be performed without increase in complexity of the procedure. However, its utility in preventing POPFs and morbidity remains unclear.

Incorporating a continuous suction system as a preventive measure against fistula-related complications in head and neck reconstructive surgery

  • Chang, Hsien Pin;Hong, Jong Won;Lee, Won Jai;Kim, Young Seok;Koh, Yoon Woo;Kim, Se-Heon;Lew, Dae Hyun;Roh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.449-457
    • /
    • 2018
  • Background Although previous studies have focused on determining prognostic and causative variables associated with fistula-related complications after head and neck reconstructive surgery, only a few studies have addressed preventive measures. Noting that pooled saliva complicates wound healing and precipitates fistula-related complications, we devised a continuous suction system to remove saliva during early postoperative recovery. Methods A continuous suction system was implemented in 20 patients after head and neck reconstructive surgery between January 2012 and October 2017. This group was compared to a control group of 16 patients at the same institution. The system was placed orally when the lesion was on the anterior side of the retromolar trigone area, and when glossectomy or resection of the mouth floor was performed. When the orohypopharynx and/or larynx were eradicated, the irrigation system was placed in the pharyngeal area. Results The mean follow-up period was $9.2{\pm}2.4$ months. The Hemovac system was applied for an average of 7.5 days. On average, 6.5 days were needed for the net drain output to fall below 10 mL. Complications were analyzed according to their causes and rates. A fistula occurred in two cases in the suction group. Compared to the control group, a significant difference was noted in the surgical site infection rate (P<0.031). Conclusions Clinical observations showed reduced saliva pooling and a reduction in the infection rate. This resulted in improved wound healing through the application of a continuous suction system.