• Title/Summary/Keyword: Downward flow

Search Result 252, Processing Time 0.024 seconds

Control of vortex shedding from circular cylinder by acoustic excitation (원통내부의 음향여기에 의한 와류유출제어)

  • Kim, Gyeong-Cheon;Bu, Jeong-Suk;Lee, Sang-Uk;Gu, Myeong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1649-1660
    • /
    • 1996
  • The flow around a circular cylinder was controlled by an acoustic excitation issued from a thin slit along the cylinder axis. The static pressure distributions around the cylinder wall and flow characteristics in the near wake have been measured. Experiments were performed under three cases of Reynolds number, 7.8 * 10$\^$4/, 2.3 * 10$\^$5/ and 3.8 * 10$\^$5/. The effects of excitation frequency, sound pressure level and the location of the slit were examined. Data indicate that the excitation frequency and the slit location are the key parameters for controlling the separated flow. At Re$\_$d/, = 7.8 * 10$\^$4/, the drag is reduced and the lift is generated to upward direction, however, at Re$\_$d/, =2.3 * 10$\^$5/ and 3.8 * 10$\_$5/, the drag is increased and lift is generated to downward direction inversely. It is thought that the lift switching phenomenon is due to the different separation point of upper surface and lower surface on circular cylinder with respect to the flow regime which depends on the Reynolds number. Vortex shedding frequencies are different at upper side and lower side. Time-averaged velocity field shows that mean velocity vector and the points of maximum intensities are inclined to downward direction at Re$\_$d/ = 7.8 * 10$\^$4/, but are inclined to upward direction at Re$\_$d/ = 2.3 * 10$\^$5/.

Net Radiation Estimation Using Flux Tower Data and Integrated Hydrological Model: For the Seolmacheon and Chungmichen Watersheds (플럭스 타워 관측 자료 및 통합수문모형을 이용한 순복사량 산정: 설마천, 청미천 유역을 대상으로)

  • Kim, Daeun;Baek, JongJin;Jung, Sung-Won;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.3
    • /
    • pp.301-314
    • /
    • 2013
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. To understand energy flow, flux towers are up and running throughout the world. In step with, in domestic major areas, there have been observed using several flux towers. In this study, downward shortwave radiation, downward long wave radiation, and net radiation that take important part in hydro-meteorology and ecology were calculated by proposed physical equations using flux data of the Seolmacheon and Choengmicheon, then, the calculated net radiation and observed net radiation were individually compared and validated. The results confirmed applicability of physical methods for insufficient hydro-meteorological data and possibility for observed data of hydro-meteorological variables.

Directional Properties of 4 Type Constitution in Sasang Constitutional Medicine (사상의학에서 각 체질별 기운의 방향 특성)

  • Kim, Kwang-Hyeon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.21 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • 1. Objectives The purpose of this study is to find the ground why constitution must be classified into 4 types. 2. Methods I analysed the basic presuppositions to class 4 Type Constitution in Sasang Constitutional Medicine(SCM). And I connected the presuppositions with other theories from the viewpoint of directional properties of human body. 3. Results and Conclusions The most important presupposition to class 4 Type Constitution and apply to clinical therapy in SCM is that there is native strength and weakness of lung's Exhale Dispersing Qi, liver's Inhale Gathering Qi, spleen's Ascending Yin Qi and kidney's Descending Yang Qi. If there is superior tendency of Qi flow direction in human body, 6 directions(upward, downward, forward, backward, outward and inward) will be remarkable. But, in embryonic period, the outer skin is originated from the back(ectoderm) and the alimentary canal is from the front(endoderm). Therefore 4 directions(upward, downward, outward and inward) will be more remarkable, and those directions are included in the former presupposition.

  • PDF

Visualization of Flow Fields Around a Flapped Rudder (플랩이 부착된 타 주위 유동장의 가시화)

  • Kim, Seong-Dong;Kim, Jin-Gu;Lee, Gyoung-Woo;Choi, Min-Seon;Cho, Dae-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.615-620
    • /
    • 2000
  • Manoeuvrability of ships has been receiving a great deal of attention both concerning navigation safety and the prediction of ship manoeuvring characteristics, especially at the preliminary design stage. Recently, in order to improve manoeuvrability of ships, High-lift devices could be applied to design of rudder at design stage. Now, among the them, we carried out the flow visualization and investigation of flow field around a flapped rudder(trailing-edge flap). A trailing-edge flap is simply a portion of the trailing-edge section of airfoil that is hinged and which can be deflected upward or downward. Flow visualization results of flap defection shown as follow Photos including main body and flap defection.

  • PDF

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry in Small Size Pipe (2) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(2))

  • 이동원;윤찬일;주문창
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2002
  • Pressure drop were experimentally investigated for ice slurry flowing in the acrylic pipes with inner diameter of 24 mm. Ice slurry was made from 6.5% ethylene glycol-water solution, and the pipes is consisted of horizontal, vertical (upward and downward) and $90^{\circ}$ elbow pipe. The ice Packing factor (IPF) and the flow rate of the experiments were varied from 0 to 30% and from 5 to 70kg/min respectively The measured pressure drop in various pipe positions were compared with those for the solution flow (IPF=0). The pressure drop was larder than that for solution flows as the IPF increased when the flow rate was low or very high. Sharp increases in pressure drop were observed for the cases when IPF is more than 70% in horizontal and vertical pipes, whereas the pressure drop increased with the IPF simultaneously in an elbow pipe.

An experimental study on the wake structure behind a van type vehicle (Van형 자동차의 후류구조에 대한 실험적 해석(와류 형성을 중심으로))

  • 성봉주;장병희
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.51-59
    • /
    • 1988
  • The wake structure behind a van type vehicle was studied experimentally with a 5-hole yawhead probe. Through an effective calibration method of the 5-hole yawhead probe, the flow properties such as velocity vector, total pressure and static pressure were obtained on two cross sections within the wake. These results combined with the surface flow visualization performed in the previous study, yielded some information about the wake structure. When the model was placed in a stream with zero yaw angle, two counter rotating vortices were observed behind the model which pull down the surface flow on each side of the model. With increasing the yaw angle, the surface flow on the windward side changed to divide the flow in two directions, one flows upward on the upper part and the other flows downward on the lower part of the windward side. Hence a new weak vortex was created on the upper windward side, which resulted 3 vortices within the wake. The size and the strength of the vortices increased with yaw angle.

  • PDF

Reconstruction of Density Distribution for Unsteady and Asymmetric Flow Using Three-dimensional Digital Speckle Tomography (3차원 디지털 스펙클 토모그래피를 이용한 비정상 비대칭 유동의 밀도 분포 재건)

  • Kim, Yong-Jae;Ko, Han-Seo;Baek, Seung-Hwan
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.21-24
    • /
    • 2006
  • Transient and asymmetric density distributions have been investigated by a digital speckle tomography with a novel integration method. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and unsteady. The speckle movements which have been formed by a ground glass between no flow and downward butane flow from an elliptical nozzle have been calculated by a cross-correlation tracking method so that those distances can be transferred to deflection angles of laser rays for density gradients. A novel integration method has been developed to obtain projection data from the deflection angles for the speckle tomography. The unsteady density fields have been reconstructed from the accurate projection values by the digital speckle tomography method using the developed integration method.

  • PDF

Fluidelastic instability of a curved tube array in single phase cross flow

  • Kang-Hee Lee;Heung-Seok Kang;Du-Ho Hong;Jong-In Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1118-1124
    • /
    • 2023
  • Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6×9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability.

Helium-Air Exchange Flow Through Openings with Vertical Partitions (수직평판을 삽입한 개구부의 헬륨 및 공기 치환류)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.79-87
    • /
    • 2000
  • This paper describes experimental investigations of helium-air exchange flow through openings with vertical partitions. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. Exchange flow rates are investigated experimentally by using partitioned opening and opening with extended partition to assess fluids interference of the exchange flow at the stand pipe rupture accident. A tests vessel with the two types of opening on top of test cylinder is used in the experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Amplitude and progress of interference fringes of the flows are observed and used as a support in comparison with the exchange flow rates. Flow passages of upward flow of the helium and downward flow of the air for both two types of the opening are separated by inserted partition within the opening, but in the case of partitioned opening, unseparated flow is formed at the opening entrance and the two flows interface. The exchange flow rate for the partitioned opening is not greater than that of the opening with extended partition because of the fluids interference at the entrance of opening. Finally, the fluids interference at the opening entrance is found to be one of important factors on the helium-air exchange flow rate.

  • PDF

Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator (알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험)

  • Kim Nae-Hyun;Shin Tae-Ryong;Sim Yong-Sup
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.