Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

  • Hong, Min;Xin, Huanhai;Liu, Weidong;Xu, Qian;Zheng, Taiying;Gan, Deqiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.320-328
    • /
    • 2016
  • The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

출력변동 저감 및 출력범위 예측 향상을 위한 풍력-연료전지 하이브리드 시스템의 운영방법 (Operation Scheme to Regulate the Active Power Output and to Improve the Forecasting of Output Range in Wind Turbine and Fuel-Cell Hybrid System)

  • 김윤성;문대성;원동준
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.531-538
    • /
    • 2009
  • The paper deals with an operation scheme to improve the forecasting of output range and to regulate the active power output of the hybrid system consisting of a doubly fed induction generator (DFIG) and a fuel-cell. The power output of the wind turbine fluctuates as the wind speed varies and the slip power between the rotor circuit and power converter varies as the rotor speed change. The power fluctuation of a DFIG makes its operation difficult when a DFIG is connected to grid. A fuel cell system can be individually operated and adjusted output power, hence the wind turbine and fuel cell hybrid system can overcome power fluctuation by using a fuel-cell power control. In this paper, a fuel-cell is performed to regulate the active power output in comparison with the regulated active power output of a DFIG. And it also improves the forecasting of output range. Based on PSCAD/EMTDC tools, a DFIG and a proton exchange membrane fuel cell(PEMFC) is simulated and the dynamics of the output power in hybrid system are investigated.

매트릭스 컨버터를 이용한 풍력발전용 DFIG 시뮬레이터 검증 (Verification of DFIG Simulator for Wind Power Generation using Matrix Converter)

  • 서영거;고종선;최남섭;한병문;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.326-328
    • /
    • 2008
  • 본 논문의 목표는 실제 시스템과 가장 유사한 이중여자 유도발전기(Doubly-Fed Induction Generator)의 시뮬레이터를 구현하고 실험을 통해서 그것을 검증하는 것이다. 바람의 속도를 2D 룩업 테이블을 이용하여 데이터화 한 후 터빈 모델의 입력으로 인가한다. 터빈 모델의 파라미터는 실험용 이중여자 유도발전기의 것과 동일하게 설정하여 실제 시스템과 유사하게 하였다. 지금까지는 이중여자 유도발전기를 모사하기 위하여 매트랩(Matlab) 등을 이용하였지만 실제와 다소 다르다는 문제와 구현하기 힘들다는 문제를 가지고 있었다. 하지만 본 논문에서는 심플로러(Simplorer)를 이용하여 쉽고 정확한 시뮬레이터를 구현하였다. 터빈과 이중여자 유도발전기는 기어를 이용하여 직결함으로써 실제 시스템과 매우 가깝게 모사하였으며 이중여자 유도발전기의 회전자를 여자시키기 위해 이산 캐리어 변조 방법을 이용하여 매트릭스 컨버터를 구동하였다. 그리고 실험을 통해서 시뮬레이터의 결과와 실험 결과의 비교 및 검증을 한다. 궁극적으로 어떤 지역의 바람의 품질과 발전량 등 중요한 정보를 얻기 위해 실제 크기의 발전기를 설치하지 않고 본 논문에서 개발한 시뮬레이터를 이용하여 쉽게 그 정보들을 얻을 수 있다.

  • PDF

풍력 발전단지의 출력 지령값을 고려한 계통 연계 운영 방안 (A New Control Scheme of Wind Farm Considering P,Q References)

  • 최정현;박진우;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1172-1173
    • /
    • 2008
  • At the moment, the control ability of wind farms is a prime research concern for the grid integration of large wind farms, due to their required active role in the power system. As more wind turbines are installed, the power from wind energy will start to replace conventional generation units and its influence on power systems cannot be neglected. Besides, because of the intermittent nature of wind the output power of wind turbines fluctuates according to wind speed variation. Especially an isolated power system with small capacity such like Jeju needs more systematic solutions and regulations(grid code). This paper presents the idea of approach for centralized operating wind farm strategy to regulate the wind farm power production to the reference power ordered by the system operator. The doubly fed induction generator(DFIG) can control active and reactive power in feasible range. So wind farm comprised of DFIG has the possibility of a controllable component in the power system. The presented wind farm control has a hierarchical structure with both a wind farm control level and a wind turbine control level.

  • PDF

분산전원용 1MW급 권선형유도발전기 제어 (Control of a 1MW-class Doubly-fed Induction Generator for Distributed Resources)

  • 박정우;이기욱;김동욱;염기대;이광수;박진순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.483-486
    • /
    • 2005
  • 국내에서 대체에너지 공급 비율을 보면 청정에너지로 분류할 수 있는 태양열에너지, 태양광 에너지, 풍력에너지를 모두 합하여 대체에너지의 10% 이하이며, 대체에너지 비율의 90% 이상을 폐기물로부터 얻은 에너지가 차지하고 있는 실정이다. 신재생에너지원에는 여러 종류가 있지만 해양에너지원에 대해 대상을 설정하고 이에 대한 부존량을 살펴보면 진도 주변의 해역에서 조류발전 부존량이 약 362만 kW가 되며, 시화호와 새만금 등지에서의 조력발전 부존량이 650만 kW, 동해안 후포 연안을 비롯한 파력발전 부존량이 20만 kW가 되는 것으로 알려져 있다. 이에 따라 해양에너지를 실용화하기 위한 연구가 국내외에서 연구되고 있다. 본 논문은 권선형유도발전기를 갖는 조류발전 시스템을 대상으로 연구한 결과로 권선형유도발전기를 제어하기 위한 전력변환장치 개발과 관련한 내용이다. 신재생에너지원이 발전 단가 측면에서 경제성을 갖기 위해서 발전기 용량은 5MW 급까지 대용량화 되어 있는 단계이지만 국내에서는 아직 MW급 이상이 되는 권선형유도발전기와 권선형유도발전기를 제어하는 전력변환장치에 대한 연구 실적이 없는 상황이다. 이에 본 논문에서는 IMW급의 권선형유도발전기에 대한 개발 사례를 소개하면서 유효전력제어, 역률제어 특성과 운전 속도에 따라 변동되는 회전자 측에서의 피상전력 제어 특성에 대해 고찰하고자 한다.

  • PDF

Adaptive Gain-based Stable Power Smoothing of a DFIG

  • Lee, Hyewon;Hwang, Min;Lee, Jinsik;Muljadi, Eduard;Jung, Hong-Ju;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2099-2105
    • /
    • 2017
  • In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. The simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

Fault Response of a DFIG-based Offshore Wind Power Plant Taking into Account the Wake Effect

  • Kim, Jinho;Lee, Jinsik;Suh, Yongsug;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.827-834
    • /
    • 2014
  • In order to meet the low voltage ride-through requirement in a grid code, a wind power plant (WPP) has to stay connected to a grid, supporting the voltage recovery for a grid fault. To do this, a plant-level controller as well as a wind generator (WG) controller is essential. The dynamic response of a WPP should be analyzed in order to design a plant-level controller. The dynamic response of a WPP for a grid fault is the collective response of all WGs, which depends on the wind speed approaching the WG. Thus, the dynamic response of a WPP should be analyzed by taking the wake effect into consideration, because different wind speeds at WGs will result in different responses of the WPP. This paper analyzes the response of a doubly fed induction generator (DFIG)-based offshore WPP with a grid fault taking into account the wake effect. To obtain the approaching wind speed of a WG in a WPP, we considered the cumulative impact of multiple shadowing and the effect of the wind direction. The voltage, reactive power, and active power at the point of common coupling of a 100 MW DFIG-based offshore WPP were analyzed during and after a grid fault under various wind and fault conditions using an EMTP-RV simulator. The results clearly demonstrate that not considering the wake effect leads to significantly different results, particularly for the reactive power and active power, which could potentially lead to incorrect conclusions and / or control schemes for a WPP.

Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석 (Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter)

  • 김일환;강경보;김재홍;문상호;오성보;김세호
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.150-157
    • /
    • 2005
  • 본 논문에서는 이중여자 유도발전기의 회전자에 back to back 컨버터가 채용된 가변속 풍력터빈 시스템의 모델링과 해석을 나타내었다. 제어시스템의 특성을 파악하기 위해서 시뮬레이션에서는 Psim 프로그램을 사용하여 660[kW] 의 출력정격을 갖는 시스템을 모델로 하였다. 모델링에서는 블레이드 제어 시스템 모델과 회전자와 계통선에 연결된 컨버터 시스템을 모델링 하였다. 풍속의 변화에 따라 원하는 출력을 얻을 수 있도록 피치각을 제어하여 정격풍속 이하에서도 최대출력이 발생하도록 하였고, 정격풍속 이상에서는 회전자 속도를 일정하게 하여 정격출력을 유지할 수 있도록 하였다. 또한 무효전력을 제어하여 출력의 역률을 제어하였다. 제안한 해석방법의 타당성을 검증하기 위하여 풍속변화에 따른 모델 시스템의 시뮬레이션 결과 값들과 제주행원 풍력발전 단지에서 운용되고 있는 V47 660[kW] 시스템의 실측 결과들과 서로 비교 검증하여 제안한 해석 방법의 타당성을 입증하였다.

최대 전압 강하에 비례하는 무효전류 공급 루프를 이용한 DFIG 풍력단지의 계층전압제어 (Hierarchical Voltage Regulation of a DFIG-based Wind Power Plant Using a Reactive Current Injection Loop with the Maximum Voltage Dip for a Grid Fault)

  • 박건;김진호;강용철
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1334-1339
    • /
    • 2016
  • In a power grid that has a high wind power penetration, the fast voltage support of a wind power plant (WPP) during the grid fault is required to stabilize the grid voltage. This paper proposes a voltage control scheme of a doubly-fed induction generator (DFIG)-based WPP that can promptly support the voltage of the point of common coupling (PCC) of a WPP during the grid fault. In the proposed scheme, the WPP and DFIG controllers operate in a voltage control mode. The DFIG controller employs two control loops: a maximum voltage dip-dependent reactive current injection loop and a reactive power to voltage loop. The former injects the reactive power in proportion to the maximum voltage dip; the latter injects the reactive power in proportion to the available reactive power capability of a DFIG. The former improves the performance of the conventional voltage control scheme, which uses the latter only, by increasing the reactive power as a function of the maximum voltage dip. The performance of the proposed scheme was investigated for a 100-MW WPP consisting of 20 units of a 5-MW DFIG under various grid fault scenarios using an EMTP-RV simulator. The simulation results indicate that the proposed scheme promptly supports the PCC voltage during the fault under various fault conditions by increasing the reactive current with the maximum voltage dip.

풍력터빈 상태진단에 적용된 다양한 신경망 모델의 유효성 비교 (Comparison of the effectiveness of various neural network models applied to wind turbine condition diagnosis)

  • 응고만투안;김창현;딘민차우;박민원
    • 한국산업정보학회논문지
    • /
    • 제28권5호
    • /
    • pp.77-87
    • /
    • 2023
  • 재생 에너지 생성에서 중요한 역할을 하는 풍력 터빈은 작동 상태를 정확하게 평가하는 것이 에너지 생산을 극대화하고 가동 중지 시간을 최소화하는 데 매우 중요하다. 이 연구는 풍력 터빈 상태 진단을 위한 다양한 신경망 모델의 비교 분석을 수행하고 센서 측정 및 과거 터빈 데이터가 포함된 데이터 세트를 사용하여 효율성을 평가하였다. 분석을 위해 2MW 이중 여자 유도 발전기 기반 풍력 터빈 시스템(모델 HQ2000)에서 수집된 감시 제어 및 데이터 수집 데이터를 활용했다. 활성화함수, 은닉층 등을 고려하여 인공신경망, 장단기기억, 순환신경망 등 다양한 신경망 모델을 구축하였다. 대칭 평균 절대 백분율 오류는 모델의 성능을 평가하는 데 사용되었다. 평가를 바탕으로 풍력 터빈 상태 진단을 위한 신경망 모델의 상대적 효율성에 관한 결론이 도출되었다. 본 연구결과는 풍력발전기의 상태진단을 위한 모델선정의 길잡이가 되며, 고도의 신경망 기반 기법을 통한 신뢰성 및 효율성 향상에 기여하고, 향후 관련연구의 방향을 제시하는데 기여한다.