• Title/Summary/Keyword: Doublet

Search Result 214, Processing Time 0.032 seconds

Implementation of Impulse Radar System in Time Domain within Laboratory Unit (시영역에서 임펄스 레이더 시스템의 실험적 구현)

  • Doojin Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.2
    • /
    • pp.93-98
    • /
    • 2024
  • This paper presents the method to extract the ultrawide-band (UWB) signal and proposes the simple impulse radar system for sensing real-based target within close-range area. The proposed impulse radar system consists of impulse generator, ultrawide-band antennas, function generator, and digital oscilloscope. It is verified by experiment that a differentiated Gaussian pulse is generated with 200ps of pulse width and corresponding spectrum from 0.3 to 4.7 GHz once a sinusoidal wave with 10MHz is excited. The Gaussian doublet is received by identical antennas and it is shown that the UWB pule width of 328ps and its spectrum is from 0.9 to 4.4 GHz. It is confirmed that the UWB pulse is extracted when the real-based targets such as circular target with 4cm radius and corner reflector are placed at the close-range area.

Ultrastructure of Germ Cells, Cyst Epithelial Cells and Interstitial Cells during Spermatogenesis of the Stone Flounder, Kareius bicoloratus (돌가자미 Kareius bicoloratus의 정자형성과정 중 생식세포, Cyst 상피세포 및 간질세포의 미세구조)

  • Jun, Je-Cheon;Chung, Ee-Yung;Yang, Young Chul
    • Korean Journal of Ichthyology
    • /
    • v.18 no.4
    • /
    • pp.311-318
    • /
    • 2006
  • Ultrastructure of germ cells, the cyst epithelial cells and interstitial cells during spermatogenesis of the stone flounder, Kareius bicoloratus (Pleuronectidae) sampled on the west coast of Korea were investigated by electron microscopic observations. In the primary spermatocyte, the synaptonemal complexes appear in the zygotene stage of the prophase during maturation division. In the growing testis, especially, the interstitial cells (Leydig cells) appear near the primary, secondary spermatocytes and spermatids. Well-developed interstitial cells (steroid hormone secreting cells) which are located in the interlobular space in growing testis have three morphological characteristics of a vesicular nucleus, mitochondria with tubular cristae and smooth endoplasmic reticulum. During spermatogenesis, the primary and secondary spermatocytes attach to the cyst epithelial cell (Sertoli cell) having an elongated ovoid or triangular nucleus and several mitochondria in the cytoplasm. In the growing testis, lipid droplets, the mitochondrial rosettes and glycogen particles appear in the cytoplasm of the cyst epithelial cells near the secondary spermatocytes and spermatids. Particularly, the mitochondria, endoplasmic reticulum, little lipid droplets and the large amount of glycogen particles are present in the cytoplasm of the cyst epithelial cell in the late growing testis. In the late stage of spermiogenesis, the proximal centriole is joined to the nuclear envelope, the distal centriole forms the basal body of the flagellum and gives rise to the axial filament of the flagellum. No acrosome of the sperm is formed as seen in other teleost fish. The head of the spermatozoon is approximately $3{\mu}m$ in length and its tail is about $30{\mu}m$ in length. The axoneme of the tail flagellum of the spermatozoon consists of nine outer doublet microtubules at the periphery and two centrial singlet microtubules at the center. The spermatozoon of this species has two axonemal lateral fins. Especially, the cyst epithelial cells which located near groups of gametes in the various stages, show three functions: nutrition, phagocytosis and steroidogenesis. Especially, the nuclei of cyst epithelial cells in the recovery stage of the testicular developmental stages appear to be irregular in shape after spermiation. Of three functions of the cyst epithelial cell, several characteristics of phagocytosis are showed in the cytoplasm of the cyst epithelial cells in the recovery stage of the testicular developmental stages. At this stage, therefore, it is assumed that the cyst epithelial cells are involved in degeneration and resorption of undischarged germ cells after spermiation.

Magnetic Properties of Superparamagnetic Ni-Zn Ferrite for Nano·Bio Fusion Applications (나노·바이오 융합응용을 위한 초상자성 Ni-Zn Ferrite의 자기적 특성연구)

  • Lee, Seung-Wha;Ryu, Yeon-Guk;Yang, Kea-Joon;An, Jung-Su;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.100-105
    • /
    • 2005
  • $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticles have been prepared by a sol-gel method. The structural and magnetic properties have been investigated by DTA/TGA, XRD, SEM, and $M\ddot{o}ssbauer$ spectroscopy, VSM. $Ni_{0.9}Zn_{0.1}Fe_2O_4$ powder that was annealed at $300^{\circ}C$ has spinel structure and behaved superparamagnetically. The estimated size of superparammagnetic Ni-Zn ferrite nanoparticle is around 10 nm. The hyperfine fields at 13 K for the A and B patterns were found to be 533 and 507 kOe, respectively. The blocking temperature ($T_B$) of superparammagnetic $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticle is about 250 K. The magnetic anisotropy constant and relaxation time constant of $Ni_{0.9}Zn_{0.1}Fe_2O_4$ nanoparticle were calculated to be $1.6\times10^6\;ergs/cm^3$ and ${\tau}_0=5.0{\times}10^{-13}$ s, respectively. Also, Temperature increased up to $43^{\circ}C$ within 10 minutes under AC magnetic field of 7 MHz. It is considered that $Ni_{0.9}Zn_{0.1}Fe_2O_4$ powder that was annealed at $300^{\circ}C$ is available for biomedicine application such as hyperthermia, drug delivery system and contrast agents in MRI.

Characterization and Conversion Electron Mössbauer Spectroscopy of HoMn1-x-FexO3 Thin Films by Pulsed Laser Deposition (PLD를 이용한 HoMn1-x-FexO3 박막 제조 및 후방 산란형 뫼스바우어 분광 연구)

  • Choi, Dong-Hyeok;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.18-21
    • /
    • 2007
  • The hexagonal $HoMn_{1-x}-Fe_xO_3$(x=0.00, 0.05) thin films were prepared using pulsed laser deposition(PLD) method on $Pt/Ti/SiO_2/Si$ substrate. The microstructure and magnetic properties have been studied by x-ray diffraction(XRD), atomic force microscopy (AFH), scanning electron microscope(SEM:), x-ray photoelectron spectroscopy(XPS), and conversion electron $M\"{o}ssbauer$ spectroscopy(CEMS). From the analysis of the x-ray diffraction patterns, the crystal structure for all films was found to be a hexagonal($P6_3cm$), which was preferentially grown along(110) direction. The lattice constant $c_0$ of the film with x=0.05 was close to that of single crystal, whereas lattice constant $a_0$ with respect to single crystal shows a slight decrease. This difference of lattice parameters between film and single crystal was caused by the lattice mismatch between the film and $Pt/Ti/SiO_2/Si$ substrate. Conversion electron $M\"{o}ssbauer$ spectrum of $HoMn_{0.95}Fe_{0.05}O_3$ thin film shows an asymmetry doublet absorption ratio at room temperature, which is due to the oriented direction of crystallographic domains. This is corresponding with analysis of x-ray diffraction. The quadrupole splitting(${\Delta}E_Q$) at room temperature is found to be $1.62{\pm}0.01mm/s$. This large ${\Delta}E_Q$ was caused by asymmetry environment surrounding Fe ion.

Development of Prism Dot-sight Combined with Thermal Imaging Camera (열영상 카메라가 결합된 프리즘 도트사이트 개발)

  • Park, Seung-Hwan;Jung, Bo-Seon;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.479-485
    • /
    • 2014
  • Purpose: This study relates to the development of the prism dot-sight combined with the thermal imaging camera. Methods: We have placed a reflector designed to the doublet type in the front of a BS (beam splitting) prism, have placed an OLED panel and a dot reticle generator to the top and bottom of the reflecting surface of the BS prism, and have placed a detachable magnifier between the BS prism and the observer by which the observer can see the magnified image of the OLED panel. By doing this, we were able to configure the new type prism dot-sight combined with the thermal imaging camera. Results: By placing the removable magnifier designed with a new type between the BS prism and the observer, we could design the new type prism dot-sight which performs the role of the dot sight by removing the magnifier during the day-time, and performs the role of the night scope during the night-time by which we can observe the enlarged image of the thermal imaging camera through the BS prism by attaching the removable magnifier. Conclusions: In this study, we have developed the prism dot-sight combined with the thermal imaging camera which is able to play the role of the day or night scope selectively, by disposing the designed magnifier characterized by the focal length of 44 mm, the viewing angle of ${\pm}7.0^{\circ}$, and the MTF value of 0.5 or more at the criterion of 50 lp/mm and the 0.7 field between the BS prism and the observer. By doing so, we could design and fabricate the new type prism dot-sight combined with the thermal imaging camera which can further increase the rapidity of firing and provide more convenience in the mounting of a firearm than the detachable combination of an existing dot sight and an existing night scope.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Case Study on Groß Schönebeck EGS Project Research in Germany (독일 그로스 쉐네벡 EGS 실증 프로젝트 연구사례)

  • Min, Ki-Bok;Park, Sehyeok;Zimmermann, Gunter
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.320-331
    • /
    • 2015
  • This paper presents a case study of an enhanced geothermal system(EGS) demonstration project conducted in $Gro{\ss}$ $Sch{\ddot{o}}nebeck$, Northerm Germany, focusing on hydraulic stimulation. The project was conducted with doublet system in sandstone and volcanic formations at 4 - 4.4 km depth. Under normal faulting to strike-slip faulting stress regime, hydraulic stimulations were conducted at injection and production wells by massive waterfrac and gel-proppant fracturing. Injectivity index increased from $0.97m^3/(hr^*MPa)$ to $7.5m^3/(hr^*MPa)$ and productivity index increased from $2.4m^3/(hr^*MPa)$ to $10.1m^3/(hr^*MPa)$ by a series of hydraulic stimulations at both wells. After circulation tests through injection and production wells, however, productivity index decreased from $8.9m^3/(hr^*MPa)$ to $0.6m^3/(hr^*MPa)$ in two years. Slip tendency analysis for the stimulation in volcanic layer estimated the required pressure for shear slip and its preferred orientations and it showed reasonable match with actual stimulation results. Through the microseismicity observation for the stimulation of volcanic formation, only 80 seismic events with its moment magnitudes in -1.8<$M_W$<-1.0 were observed, which are unexpectedly low for EGS hydraulic stimulation.

The Effect of the Telephone Channel to the Performance of the Speaker Verification System (전화선 채널이 화자확인 시스템의 성능에 미치는 영향)

  • 조태현;김유진;이재영;정재호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.12-20
    • /
    • 1999
  • In this paper, we compared speaker verification performance of the speech data collected in clean environment and in channel environment. For the improvement of the performance of speaker verification gathered in channel, we have studied on the efficient feature parameters in channel environment and on the preprocessing. Speech DB for experiment is consisted of Korean doublet of numbers, considering the text-prompted system. Speech features including LPCC(Linear Predictive Cepstral Coefficient), MFCC(Mel Frequency Cepstral Coefficient), PLP(Perceptually Linear Prediction), LSP(Line Spectrum Pair) are analyzed. Also, the preprocessing of filtering to remove channel noise is studied. To remove or compensate for the channel effect from the extracted features, cepstral weighting, CMS(Cepstral Mean Subtraction), RASTA(RelAtive SpecTrAl) are applied. Also by presenting the speech recognition performance on each features and the processing, we compared speech recognition performance and speaker verification performance. For the evaluation of the applied speech features and processing methods, HTK(HMM Tool Kit) 2.0 is used. Giving different threshold according to male or female speaker, we compare EER(Equal Error Rate) on the clean speech data and channel data. Our simulation results show that, removing low band and high band channel noise by applying band pass filter(150~3800Hz) in preprocessing procedure, and extracting MFCC from the filtered speech, the best speaker verification performance was achieved from the view point of EER measurement.

  • PDF

Analysis of Motion Response and Drift Force in Waves for the Floating-Type Ocean Monitoring Facilities (부유식 해상관측시설의 파랑중 운동 및 표류력 해석)

  • YOON Gil Su;KIM Yong Jig;KIM Dong Jun;KANG Shin Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.2
    • /
    • pp.202-209
    • /
    • 1998
  • A three-dimensional numerical method based on the Green's integral equation is developed to predict the motion response and drift force in waves for the ocean monitoring facilities. In this method, we use source and doublet distribution, and triangular and rectangular eliments. To eliminate the irregular frequency phenomenon, the method of improved integral equation is applied and the time-mean drift force is calculated by the method of direct pressure integration over the body surface. To conform the validity of the present numerical method, some calculations for the floating sphere are performed and it is shown that the present method provides sufficiently reliable results. As a calculation example for the real facilities, the motion response and the drift force of the vertical cylinder type ocean monitoring buoy with 2.6 m diameter and 3,77 m draft are calculated and discussed. The obtained results of motion response can be used to determine the shape and dimension of the buoy to reduce the motion response, and other data such as the effect of motion reduction due to a damper can be predictable through these motion calculations. Also, the calculation results of drift force can be used in the design procedure of mooring system to predict the maximum wave load acting on the mooring system. The present method has, in principle, no restriction in the application to the arbitrary shape facilities. So, this method can be a robust tool for the design, installation, and operation of various kinds of the floating-type ocean monitoring facilities.

  • PDF

Mossbauer study of $CoCr_xFe_{2-x}O_4$ (Mossbauer 분광법에 의한 $CoCr_xFe_{2-x}O_4$의 연구)

  • 채광표;이혁진;이재광;이성호;이영배
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.74-80
    • /
    • 2000
  • CoCr$_{x}$ Fe$_{2-x}$O$_4$(0.0$\leq$x$\leq$1.0) ferrites have been fabricated by sol-gel method. The crystallographic and magnetic properties of the samples were investigated by means of x-ray diffraction, scanning electron microscophy, Mossbauer spectroscopy and vibrating sample magnetometry. The structure of all the samples is cubic spinel type and the lattice constant decrease with increasing Cr content. The substituted Cr ions were located only in the B-site. The particle size also decreases with increasing Cr content. The Mossbauer spectra consist of two sextets due to Fe$^{3+}$ions at A- and B sites for 0.0$\leq$x$\leq$0.6, while, a paramagnetic doublet appears for 0.8$\leq$x$\leq$1.0. The magnetic hyperfine field decreases with increasing Cr content. The relaxation spectra was shown at 0.8$\leq$x$\leq$1.0 in CoCr$_{x}$ Fe$_{2-x}$O$_4$. The coercivity decreases drastically, while, the saturation magnetization decreases linearly with increasing x.ing x.

  • PDF