• Title/Summary/Keyword: Doublet

Search Result 214, Processing Time 0.024 seconds

Development of the Dot Sight Device by Using the Doublet Reflector (Doublet 반사경을 이용한 도트 사이트 장치의 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.65-69
    • /
    • 2008
  • Purpose: To develop a dot sight device for a sighting shot using the doublet reflector. Methods: We designed the singlet reflector and the doublet reflector by Sigma 2000 program and compared the one to the other. Results: In analysis of finite ray aberration, we could confirm that it has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector. If you use the doublet reflector, the central thickness of optical system become more than two times bigger than the existing one. As a result, when the image of a target object is made on the observer's retina, if you make the first side's radius of curvature equal with the second one as the case of the singlet reflector, changes in magnification are appeared. To conquer this problem, we had to make be satisfied with the afocal condition in the case of doublet reflector. Conclusions: we could develop the dot sight device for a sighting shot using the doublet reflector which has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector.

  • PDF

Longitudinal vibration of double nanorod systems using doublet mechanics theory

  • Aydogdu, Metin;Gul, Ufuk
    • Structural Engineering and Mechanics
    • /
    • v.73 no.1
    • /
    • pp.37-52
    • /
    • 2020
  • This paper investigates the free and forced longitudinal vibration of a double nanorod system using doublet mechanics theory. The doublet mechanics theory is a multiscale theory spanning between lattice dynamics and continuum mechanics. Equations of motion and boundary conditions for the double nanorod system are obtained using Hamilton's principle. Clamped-clamped and clamped-free boundary conditions are considered. Frequencies and dynamic displacements are determined to demonstrate the effects of length scale parameter of considered material and geometry of the nanorods. It is shown that frequencies obtained by the doublet mechanics theory are bounded from above (van Hove singularity) and unlike classical elasticity theory doublet mechanics theory predicts finite number of modes depending on the length of the nanotube. The present doublet mechanics results have been compared to molecular dynamics, experimental and nonlocal theory results and good agreement is observed between the present and other mentioned results. The difference between wave frequencies of graphite is less than 10% between doublet mechanics and experimental results near to the end of the first Brillouin zone.

Optical Design of Cemented Doublets by Using Equivalent Lens System (등가렌즈를 이용한 2매 접합렌즈계의 설계)

  • 전영세;김형수;이종웅;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.282-290
    • /
    • 1998
  • The equivalent lens conversion technique is applied to design achromatic doublet and aplanatic doublet. A thin doublet which has zero axial thicknesses, are corrected for the third order aberrations at first, and the thin doublet is converted into thick lens system by using the equivalent lens conversion. Two types of cemented doublets, the Fraunhofer type and the Steinheil type, are designed by using a crown glass BaK-2 and a flint glass SF-2. In the thin doublet design, there are two achromatic solutions and a aplanatic solution for the both types.

  • PDF

Finite element analysis for longitudinal vibration of nanorods based on doublet mechanics

  • Ufuk Gul;Metin Aydogdu
    • Advances in nano research
    • /
    • v.15 no.5
    • /
    • pp.411-422
    • /
    • 2023
  • In the present study, the axial vibration of the nanorods is investigated in the framework of the doublet mechanics theory. The equations of motion and boundary conditions of nanorods are derived by applying the Hamilton principle. A finite element method is developed to obtain the vibration frequencies of nanorods for different boundary conditions. A two-noded higher order rod finite element is used to solve the vibration problem. The natural frequencies of nanorods obtained with the present finite element analysis are validated by comparing the results of classical doublet mechanics and nonlocal strain gradient theories. The effects of rod length, mode number and boundary conditions on the axial vibration frequencies of nanorods are examined in detail. Mode shapes of the nanorods are presented for the different boundary conditions. It is shown that the doublet mechanics model can be used for the dynamic analysis of nanotubes, and the presented finite element formulation can be used for mechanical problems of rods with unavailable analytical solutions. These new results can also be used as references for the future studies.

A Study on the Determination of a Practical Ship Hull Form by the Streamline Tracing Method (유선추적(流線追跡)에 의(依)한 실용선형(實用船型) 결정법(決定法)에 관(關)한 연구(硏究))

  • Kyu-Jong,Cho
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-16
    • /
    • 1971
  • Ship hulls obtained by the streamline tracing method usually have characteristically drooped keel lines at the bottom, and a flattening of these bottoms would contribute considerably in utilizing these analytically obtainable hull forms in practical usage. In this dissertation, the author deals with a study on the determination of a practical hull form by the streamline tracing method with a particular emphasis on the bottom flattening problem. Investigations are centered around the form and the terms of bottom doublet distribution. Several examples are computed by varying bottom doublet sheet systematically while the main side source distribution is kept the same. The following conclusions are obtained based on those computed results: after the strength of a bottom doublet sheet can be determined more easily and efficiently by employing the concept of a control plane. If the distance from the distributed plane of the bottom doublet sheet to the control plane is defined as the control distance, the strength of the bottom doublet sheet, the flatness of traced lines, and the increment of the beam length ratio by adding the bottom doublet sheet are all related to the control distance by linear equations near the design bottom. It is observed that a better result can be obtained by using a "line-sampling method" for ${\zeta}_K>2T/L$, and a "plane-sampling method" for ${\zeta}_K{\leq}2T/L$, provided that the check points are sampled in the range ${\xi}{\leq}0.7$.

  • PDF

Assessment of PLLIF Measurement for Spray Mass Distribution of Like-Doublet Injector (Like-Doublet 인젝터의 분무 질량분포 측정을 위한 PLLIF기법의 신뢰성 평가)

  • Jung Kihoon;Koh Hyeonseok;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.1
    • /
    • pp.98-106
    • /
    • 2003
  • A PLLIF (Planar Liquid Laser Induced Fluorescence) technique has been known to be a useful tool for the measurement of the spray patterns for various spray injectors because it can obtain two-dimensional images with high spatial resolutions without any intrusion on the spray field. In case of dense spray, however, the secondary emission as well as the extinction of an incident laser beam or a fluorescence signal can cause errors in quantifying a mass distribution. Unfortunately, a like-doublet injector which has a dense spray zone at the center may not be a good example or the application of the PLLIF technique. Therefore, we took PLLIF data for the like-doublet injector with a 12 bit color CCD camera by varying laser power, and then assessed their accuracy by comparing with the data obtained with a mechanical patternator and a PDPA (Phase Doppler Particle Analyzer). The experimental results showed that the gray level of fluorescence signal increases nonlinearly due to a secondary emission at the dense spray zone but this nonlinearity can be avoided by reducing the incident laser beam power. In addition, the mass flux distribution of the spray could be obtained by using the mass concentration data from PLLIF technique and the velocity profiles of liquid drops, and this distribution showed good agreement with that of mechanical pattemator. Therefore, it is possible that the PLLIF technique can be successfully applied to finding the mass distributions of like-doublet injectors.

  • PDF

Development of Dot Sight with Prism Beam Splitter (빔분리프리즘 도트사이트 장치의 개발)

  • Lee, Dong-Hee;Jung, Bo-Seon;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.519-524
    • /
    • 2013
  • Purpose: This study relates to the development of dot-sight device, whose length is reduced, with a prism beam splitter. Methods: We developed a new dot-sight device whose length was reduced by eliminating the optical axis tilt of the doublet reflector to reduce the occurrence of the parallax and by redesigning the doublet reflector to use a prism beam splitter. Results: We could develop the new type dot-sight device having a prism beam splitter and the dot reticle generator and the doublet reflector, of which optical axises showed a T-letter type with the optical axis of the observer's eye. Conclusions: In this study, we designed and developed a new type dot sight employing a prism beam splitter that could be able to further enhance the accuracy of the fire in comparison with the traditional dot sight, thereby reducing the overall optical length of system. The new designed dot sight was able to be reduced 2.2 times on the overall optical length, and could be improved more than three times on the accuracy of shooting in the horizontal direction, than the traditional dot sight.

Study of Mg2Ni1-xFex Alloys by Mössbauer Resonance (Mössbauer 공명에 의한 Mg2Ni1-xFex 합금의 연구)

  • Song, MyoungYoup
    • Journal of Hydrogen and New Energy
    • /
    • v.10 no.2
    • /
    • pp.119-130
    • /
    • 1999
  • After preparing $Mg_2Ni_{1-x}{^{57}}Fe_x$(x=0.015, 0.03, 0.06, 0.12 and 0.24) alloys, they were studied by $M{\ddot{o}}ssbauer$ resonance. The $M{\ddot{o}}ssbauer$ spectra of x=0.015 and 0.03 alloys exhibit two doublets (doublet 1, 2). That of x=0.06 alloys shows two doublets (doublet 1,2) and one six-line, and those of x=0.12 and 0.24 alloys have only one six-line. The doublet 1 for x=0.015, 0.03 and 0.06 alloys is considered to result from a fraction of Fe in excess showing a superparamagnetic behavior. The doublet 2 is considered to result from the Fe substituted for Ni in the $Mg_2Ni$ phase. The values of isomer shift 0.24 ~ 0.28 mm/s suggest that the iron exist in the state $Fe^{+3}$. The result that the quadrapole splitting of the doublet 2 is not zero shows that the distribution of electrons around the iron is asymmetric. Their values for the doublet 2, 1.20 ~ 1.38 mm/s, approach the value of quadrapole for the oxidation number +3. The six-line showing the magnetic hyperfine interactions results from the iron which has not substituted the nickel in the $Mg_2Ni$ phase. The $M{\ddot{o}}ssbauer$ spectra of the hydrided alloys with x=0.015 and 0.03 show six-line. This suggests that the iron segregates with the hydriding reaction. The analysis results of the $M{\ddot{o}}ssbauer$ spectrum, the variation of magnetization with magnetic field, Auger electron spectroscopy and electron diffraction show the segregation of Ni and the formation of MgO. This is considered to result from the reaction of the $Mg_2Ni$ phase with the oxygen contained in the hydrogen as impurity.

  • PDF

Time-delay Estimation Method for Performance Enhancement of Underwater Source Localization using Doublet Array (Doublet 센서배열의 수중음원 위치 추정 성능 향상을 위한 시간지연 추정 기법)

  • Sim, Min-Seop;Lee, Ji-Hyeog;Lee, Hyeong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.69-76
    • /
    • 2020
  • The sound signal radiated from an underwater source is received by the hydrophone of the system, including multi-path time-delay and multi-path signal by sea surface and bottom reflection. The system using a time-delay between received signals for the source localization shows performance degradation due to incoherence by the multi-path propagation environment and the disturbance of a marine environment. Various types of array and signal processing have been used for robust source range and bearing estimation in this environment. In this paper, we use a line array composed of doublet array and an estimated time-delay correction method for robust localization performance in a multi-path propagation environment. Three doublet arrays are located on the same line, and the time-delay between signals received on each doublet array is estimated in a two-step procedure. The estimated time-delay value is obtained by the cross-correlation function and corrected by the interaction formula between the center-frequency of received signal and the geometry of the array with respect to aperture. By this proposed procedure, the range and bearing of source from array were calculated. In order to confirm the validity of the proposed method and array, we simulated localization and estimation using the Monte-Carlo method.

Development of 3X Scope with Objective Configured with Doublet+Meniscus Lens (더블렛+메니스커스렌즈 대물부를 가지는 3X 스코프 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.487-492
    • /
    • 2014
  • Purpose: This study relates to the development of the 3X scope, whose objective part is configured with a doublet + a meniscus lens. Methods: By the initial condition of the objective part having a configuration of a doublet + a singlet, we could optimize the optical system of scope in order to minimize the finite ray aberrations of the objective part and the whole optical system of scope, and so we could develope a new type 3X scope. Results: On the condition of the objective part having a configuration of a doublet + a singlet, when the optical system of scope was optimized in order to minimize the finite ray aberrations, we could find that the singlet became the meniscus type lens having the concave shape to the direction of the doublet, and the longer the distance between the doublet and the meniscus lens is, the more the finite ray aberrations are minimized. Conclusions: In this study, we could develope a new type 3X scope of which finite ray aberrations can be reduced to 1/14 than the existing scope by adopting the objective part of the 3X scope having a configuration of three lenses composed of a doublet + a singlet. We could confirm that this reduction of aberrations can be a means to increase the effective aperture than the existing scope and to shorten the length of the optical system.