• 제목/요약/키워드: Double-circuit transmission line

검색결과 63건 처리시간 0.023초

초전도 한류기를 포함한 계통의 지락사고에 대한 EMTDC 해석 (An EMTDC Analysis for Ground Faults with a Superconducting Fault Current Limiter)

  • 최효상;현옥배;고태국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.161-166
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 39 kA during the single and double line-to-ground faults, respectively. The SFCL in the transmission line is sufficient.

  • PDF

노후 가공송전선의 수명과 열용량의 평가 (Evaluation for Lifetime and Thermal Ratings for Aged Overhead Transmission Lines)

  • 김성덕
    • 전기전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2012
  • 적절한 송전용량으로 전력공급을 안정하게 유지하기 위하여 노후 가공송전선의 열용량이나 수명 평가가 더욱 중요한 관심사가 되었다. 부하정격과 이도/이격거리 모두는 송전용량을 결정하는 중요한 요소들이다. 국내의 2회선 송전선로에 대한 열용량 및 도체수명을 평가하기 위하여, 전기설비기술기준은 물론 이도 및 지상고에 대한 설계기준들이 검토된다. 상정사고를 가정하여 도체온도와 이도를 계산하고 부하용량을 증대시키기 위한 방안이 모색되었다. 본 논문에서는 노후 도체에 대한 열용량과 한계이도를 적절히 평가함으로써, 기존 전력계통의 신뢰성을 보장하기 위한 개선 방안이 제시되었다.

765 kV 송전철탑 개폐섬락 특성 (Switching Surge Flashover Characteristics of 765 kV Transmission Towers)

  • 심정운;장성철;곽주식;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.276-278
    • /
    • 1996
  • The breakdown Process in large gaps is greatly influenced by the gap geometry. Therefor full scale test are essential for the economical and reliable air insulation design. For switching surge design of 765 kV double circuit transmission line KEPRI is carrying the verifying tests using impulse voltage generator at Gochang test site. In this paper, the intermediate results of verifying tests are presented and the switching surge design criteria of 765 kV transmission tower flashover paths are discussed.

  • PDF

765kV 송전선로의 전기적 및 기계적 소음고찰 (Electrical and Mechanical Noise Study of the 765kV Transmission Line)

  • ;이동일;구자윤
    • 소음진동
    • /
    • 제6권1호
    • /
    • pp.89-95
    • /
    • 1996
  • 송전전압이 500kV 이상이 되면, 송전도체의 코로나 방전에 의해 발생되는 가청소음, 험소음이 송전선로의 도체 선정에 중요한 요소가 되며 또한 바람에 의한 철탑과 도체의 풍소음도 발생한다. 본 논문은 세계최초로 765kV 2회선 교류 송전선을 개발하기 위해 건설한 한전 전력연구웜 765kV 시험송전선로의 상당 480mm$^{2}$ 도체 6가닥으로 구성된 송전선 구성에서 가정소음, 험소음, 풍소음의 통계적인 분석 결과를 나타내었다. 분석결과를 보면 6-480mm$^{2}$ 도체와 철탑구성이 가청소음 설계목표치인 50dB(A)를 만족함을 알 수 있다.

  • PDF

Design of T/R Switch Using LTCC Technology

  • Sim, Sung-Hun;Kang, Chong-Yun;Park, Ji-Won;Yoon, Young-Joong;Kim, hyun-Jai;Park, Hyung-Wook;Yoon, Seok-Jin
    • 한국세라믹학회지
    • /
    • 제40권4호
    • /
    • pp.375-379
    • /
    • 2003
  • In this paper, a novel design of multilayer ceramic-based Transmit/Receive (T/R) switch using Low Temperature Co-fired Ceramic (LTCC) technology have been presented. Compact T/R switch has been designed by transforming quarter-wave transmission line to its lumped equivalent circuit. Especially, high-Q three dimensional inductors with double strip have been proposed and incorporated. The proposed inductor has been modeled by multi-conductor coupled lines. A measured inductor quality factor (Q) of 80 and a Self-Resonance Frequency (SRF) of 6.6 GHz have been demonstrated. The inductor library has been incorporated into the design of WCDMA T/R switch.

신경회로망을 이용한 송전선로 보호용 방향 개전 및 고장상 선택 알고리즘 (A Fault Classification and Direction Estimation Algorithm by Neural Network)

  • 최창열;이명수;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.332-334
    • /
    • 2003
  • The direction and the type of a fault on a transmission line needs to be identified rapidly and correctly. This paper presents a approach to identify fault direction and type with neural network on double circuit transmission line. A neural network based on self organization map(SOM) provides the ability to accurately classify the fault type and to select of a fault direction. In this paper, proposed algorithm uses different patterns of the associated voltages and currents in order to identify fault clusters.

  • PDF

풍소음 저감용 특수 다중도체 방식의 3차원 전계해석 (3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise)

  • 민석원;송기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.254-258
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was developed to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise. When we applied this method to 765 kV double circuit transmission line, we found calculation error of this method was within a reasonable boundary of 1%.

  • PDF

345kV 및 154kV 송전철탑의 뇌사고율 예측계산 (The Calculation of Lightning Flashover rate of 345kV/154kV Transmission Tower)

  • 심응보;우정욱;곽주식;민병욱;황정일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2001
  • This paper described the calculation results of lightning flashover rate on the 345kV and 154kV transmission system of KEPCO. The back-flashover rate and shielding failure rate was calculated by FLASH(lightning flashover rate calculation program from IEEE) and KEPRI's own program which is based on the EGM(Electro Geometrical Model) method. The estimated lightning flashover late of 345kV transmission system of double circuit was 1.0 flash per 100km-year, and the lightning flashover rate of 154kV transmission line was 2.0 flash Per 100km-year approximately.

  • PDF

가공송전선로의 비상용량 응용과 평가 (Application and Evaluation of Emergency Rates in Overhead Transmission Lines)

  • 김성덕
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.442-446
    • /
    • 2014
  • 본 논문에서는 ACSR 가공송전선로의 전력공급 신뢰도를 증진시키기 위한 비상정격의 적용방안에 대하여 기술하였다. 전력산업의 재편으로 인하여 한국전력은 물론 세계의 대부분 전력회사들은 새로운 투자를 하지 않으면서 경제적인 전략들만 모색하여 왔다. 그러나 전력수요가 급격히 증가하였으나 발전량의 증가는 충분히 따라가지 못했다. 따라서 첨두부하 시나 송전선로의 고장의 경우에 기존 송전선로의 송전용량을 증가시키기 위하여, 단시간 또는 장시간정격과 같은 비상용량을 적용하는 방법을 제안한다. 만약 첨두부하시, 정적송전용량 대신에 장시간 비상용량을 적용하면 10 % 또는 그 이상의 전력증대가 가능하다. 또한 2회선 송전선로 중 1회선 고장이나 과부하 경우에 비상용량이 효과적으로 사용될 수 있음을 확인하였다.

Small-Sized High-Power PIN Diode Switch with Defected Ground Structure for Wireless Broadband Internet

  • Kim, Dong-Wook
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.84-86
    • /
    • 2006
  • This letter presents a small-sized, high-power single-pole double-throw (SPDT) switch with defected ground structure (DGS) for wireless broadband Internet application. To reduce the circuit size by using a slow-wave characteristic, the DGS is used for the quarter-wave (${\lambda}$/4) transmission line of the switch. To secure a high degree of isolation, the switch with DGS is composed of shunt-connected PIN diodes. It shows an insertion loss of 0.8 dB, an isolation of 50 dB or more, and power capability of at least 50 W at 2.3 GHz. The switch shows very similar performance to the conventional shunt-type switch, but the circuit size is reduced by about 50% simply with the use of DGS patterns.

  • PDF