• Title/Summary/Keyword: Double-Screen

Search Result 83, Processing Time 0.029 seconds

An alternative method for smartphone input using AR markers

  • Kang, Yuna;Han, Soonhung
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.3
    • /
    • pp.153-160
    • /
    • 2014
  • As smartphones came into wide use recently, it has become increasingly popular not only among young people, but among middle-aged people as well. Most smartphones adopt capacitive full touch screen, so touch commands are made by fingers unlike the PDAs in the past that use touch pens. In this case, a significant portion of the smartphone's screen is blocked by the finger so it is impossible to see the screens around the finger touching the screen; this causes difficulties in making precise inputs. To solve this problem, this research proposes a method of using simple AR markers to improve the interface of smartphones. A marker is placed in front of the smartphone camera. Then, the camera image of the marker is analyzed to determine the position of the marker as the position of the mouse cursor. This method can enable click, double-click, drag-and-drop used in PCs as well as touch, slide, long-touch-input in smartphones. Through this research, smartphone inputs can be made more precise and simple, and show the possibility of the application of a new concept of smartphone interface.

Improvement of Smartphone Interface Using AR Marker (AR 마커를 이용한 스마트폰 인터페이스의 개선)

  • Kang, Yun-A;Han, Soon-Hung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.361-369
    • /
    • 2011
  • As smartphones came into wide use recently, it has become increasingly popular not only among young people, but middle-aged people as well. Most smartphones use capacitive full touch screen, so touch commands are made by fingers unlike the PDAs in the past that use touch pens. In this case, a significant portion of the smartphone's screen is blocked by the finger so it is impossible to see the screens around the finger touching the screen, and difficulty occurs in precise control used for small buttons such as qwerty keyboard. To solve this problem, this research proposes a method of using simple AR markers to improve the interface of smartphones. Sticker-form marker is attached to fingernails and placed in front of the smartphone camera Then, the camera image of the marker is analyzed to determine the orientation of the marker to perceive as onRelease() or onPress() of the mouse depending on the marker's angle of rotation, and use its position as the position of the mouse cursor. This method can enable click, double-click, drag-and-drop used in PCs as well as touch, slide, long-touch-input in smartphones. Through this research, smartphone inputs can be made more precise and simple, and show the possibility of the application of a new concept of smartphone interface.

A Study on the Chest Radiography by Simultaneous Double Radiation Quality (동시(同時) 이선질(二線質)에 의한 Chest Radiography의 연구(硏究))

  • Hayashi, Tare;Ishida, Yuji;Shindo, Koichi;Maeda, Mika
    • Journal of radiological science and technology
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 1989
  • We have developed of the exposure technique for the chest radiography to get different contrast in left and right lung fields simultaneously for the effective diagnosis, I.E., get high contrast to detect tuberculosis, dispersal shadow or exudative lesions of early tuberculosis and get better sharpness and wider latitude to detect growing lesions of lung cancer or lesions overlapped with bones. As a result, by using an additional filter Cu 1.2mm with BX-III screen side and sheet of yellow cellophane on BF-III screen side at the conventional KV ($80KV{\sim}100KV$) for the chest X-ray, we can get similar densities in both left and right lung fields and, thus, this method is considered to be very effective for the quality diagnosis for the routine chest radiography.

  • PDF

A Fully-Differential Correlated Doubling Sampling Readout Circuit for Mutual-capacitance Touch Screens

  • Kwon, Kihyun;Kim, Sung-Woo;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.349-355
    • /
    • 2015
  • A fully-differential touch-screen sensing architecture is presented to improve noise immunity and also support most multi-touch events minimizing the number of amplifiers and their silicon area. A correlated double sampling function is incorporated to reduce DC offset and low-frequency noises, and a stabilizer circuit is also embedded to minimize inherent transient fluctuations. A prototype of the proposed readout circuit was fabricated in a $0.18{\mu}m$ CMOS process and its differential operation in response to various touch events was experimentally verified. With a 3.3 V supply, the current dissipation was 3.4 mA at normal operation and $140{\mu}A$ in standby mode.

Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System (다겹보온자재의 보온성 비교 및 커튼개폐장치 개발)

  • Lee, Si-Young;Kim, Hark-Joo;Chun, Hee;Yum, Sung-Hyun;Lee, Hyun-Joo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • This study was accomplished to compare energy saving effects of several heat insulation materials in greenhouse and to develop new automatic opening and closing equipment which is suitable to the most effective heat insulation material. To find out more effective heat insulation material, the magnitude of heat transfer occurred through aluminum screen (ALS), non-woven fabric (NWF), double-layer aluminum screen with chemical cotton sheet (DAL), and multi-layer fabric screen material quilted with non-woven fabric, chemical cotton, poly foam, and polypropylene (MLF) were compared relatively. The results showed that the relative magnitude of heat transfer occurred through MLF was lower than DAL and ALS by 23.3% and 43.0% respectively. MLF screen material was the most effective compared with other heat insulation materials. But because of thickness, there was a need of new mechanism for automatic operation in greenhouse. Accordingly, new screen system using MLF-thick but profitable for keeping warm in greenhouse-was developed. Opening & closing equipment was designed to roll MLF with pipe axis during opening process and pull MLF with string during closing process with electric motors, clutches, drums, and so on. In hot pepper cultivation and energy saving test during winter time, the early stage yield of pepper under MLF screen system was higher than NWF by 27%, and gasoline consumption of MLF screen system was lower than NWF by 46%.

The thickness of Cu Filter to reduce 1/2 of the patient dose (X선 진단시 피폭선량을 반으로 줄이기 위한 Cu Filter의 두께)

  • Kim, Jung-Min;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Medical X-ray examination are increased double for the last $6{\sim}8$ years. Therefore a patient exposure dose should be decrease half every 7 years. We made an experiment on copper filter thickness to decrease a patient exposure dose up to half and compared to the Image quality by MTF. The results as follow 1. A thin region like extremities needs a thicker Cu filter as compared a thick region. 2. 1/2 reduction filter must be thicker when kVp Increase. 3. Exposure factor should be increas when using 1/2 reduction filter ; extremity is 4.0 times, chest 2.9 times, skull 1.62 times, and abdomen 1.58 times 4. The MTF of using 1/2 reduction filter is lower than without filter. But no difference of visual image. 5. 1/2 reduction filter compared with double speed screen showed almost same image quality.

  • PDF

The Influence of Altering Mobile Phone Interface on the Generation of Mental Model (모바일 폰의 인터페이스 변경이 멘탈모델 형성에 미치는 영향)

  • Park, Ye-Jin;Kim, Bon-Han
    • Science of Emotion and Sensibility
    • /
    • v.11 no.4
    • /
    • pp.575-588
    • /
    • 2008
  • This study is to inquire respective patterns of mental models caused by wrongful usages which can be experienced when a user who is used to a keypad-based mobile phone starts using a touch screen mobile phone and to find out the features of the user's logical process of correcting such wrongful usages to a new mental model. In addition, design improvement to be considered for easy generation of the mental model regarding touch screen mobile phones was reviewed in this study. We set up test subjects for the most frequently used seven high priority functions among touch screen phone functions and carried out the subject assessment together with interview surveys after the video observation experiment. Our test results show that test subjects who were used to keypad-based mobile phones tend to use operation knowledge related to the computer operational system(Window) or the web browse, navigation including Tap or Double Tap in order to correct the mental model when a wrongful usage is made. In addition, the result of comparison and analysis of the subject assessment and the video observation experiment data shows that wrongful usages of touch screen mobile phones mostly occurred in the field of 'information feedback' and 'navigation' among mobile phone components.

  • PDF

Double-Layer 3D Rear Projection Display System using Scattering Polarizer Film (후면투사 방식의 이중스크린 3D 프로젝션 디스플레이)

  • Kim, Tae-Ho;Seo, Jong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.421-425
    • /
    • 2007
  • A new 3D rear projection display system using double-layer polarization-selective screen systems, one stacked in front of the other, has been developed. The front and rear screens are made of scattering polarizer films, and they either diffuse-scatter or transmit the incident light depending on the polarization state of the light. The near and for images are projected onto the front and rear screens, respectively, using light waves with mutually orthogonal polarization states. The new display system produces clear high-resolution images, which are visible over a wide range of viewing angle. It was found that the impression of depth is pronounced and eyestrain is only comparable to that by 2D display systems.

Characteristics of AC Power Electroluminescent Device with the Double Dielectric Layers of Thin and Thick Barium Titanate Films ($BaTiO_3$ 박막과 후막의 2중 유전체로 구서된 AC 분산형 ELD의 특성)

  • Lee, Ju-Hyeon;Chae, Sang-Hoom;Bhattarai, B.B.;Kim, Hak-Soo;Park, Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.679-687
    • /
    • 2001
  • It is known that amorphous BaTiO$_3$ thin films have good insulating properties[1][2]. In this investigation, amorphous BaTiO$_3$ thin films were deposited by rf magnetron sputtering on thick BaTiO$_3$ films of AC powder EL devices which were fabricated by screen-printing. The electrical and optical properties of the EL devices were then investigated. Adding amorphous BaTiO$_3$ thin film, it showed that leakage current density was decreased. Especially, leakage current density was decreased more with he sample of 0.5-hour deposition than the sample of 4-hours deposition. This result led to the improvement of luminous efficiency by 11%. It could be concluded that proper amorphous BaTiO$_3$ thin film deposition improved the surface property of dielectric layer.

  • PDF

Electrochemical Monitoring of NADH Redox with NPQD-modified Electrodes for Cell Viability Assessment

  • JuKyung Lee;Hye Bin Park;Chae Won Seo;Chae Won Seo;SangHee Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.412-417
    • /
    • 2023
  • There is increasing interest in the rapid and highly sensitive monitoring of cell viability in biological and toxicological research. Conventional methods depend on optical assays using Water Soluble Tetrazolium-8 (WST-8) or 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay, which requires a large volume of samples and special instruments, necessitating shipment of clinical samples to laboratories. This paper reports on the development of a rapid and sensitive electrochemical (EC) sensor using screen printed electrode (SPE) and surface modification using 4'-mercapto-N-phenylquinone diamine (4'-NPQD), as double electron mediators, for monitoring cell viability via the measurement of nicotinamide adenine dinucleotide (NADH). We used the sensor to observe the viability of MCF-7 and doxorubicin (Dox)-treated cells. The oxidation current of NADH was measured via chronoamperometry (CA), and the EC results showed a good linear relationship when compared with NADH quantification using WST-8 assay. The analysis time was only 10 s and limit of detection (LOD) of NADH was 1.78 µM. Our EC method has the potential to replace conventional WST assays for cell viability and cytotoxicity experiments.