• Title/Summary/Keyword: Double-Layered System

Search Result 66, Processing Time 0.019 seconds

Efficient Flooding Algorithm for Mobile P2P Systems using Super Peer (슈퍼피어를 이용한 모바일 P2P시스템을 위한 효율적인 플러딩 알고리즘)

  • Kang, So-Young;Lee, Kwang-Jo;Yang, Sung-Bong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.2
    • /
    • pp.217-221
    • /
    • 2010
  • As the appearances of various new mobile devices and the explosive growth of mobile device users, many researches related to mobile P2P systems have been proceeded actively. In this paper, we propose a new search algorithm for the double-layered super peer system in the mobile environment. For the proposed search algorithm, we divide the entire experiment region into a grid of cells, each of which has the same size. The grid is configured properly by considering the communication range of a mobile device and the number of peers in the system. The proposed search algorithm is a partial flooding search method based on the directions of cells involved with the search. It reduces successfully the network traffic, but shows a low search hit ratio. To enhance the search hit ratio, we introduce a bridge-peer table for a super peer and utilize an n-way search. The experimental results show that the proposed algorithm made an average of 20~30% reduction in the number of message packets over the double-layered system. The success ratio was also improved about 2~5% over the double-layered system.

Analysis of the Stress Characteristics of Double Layered Tube at Elevated Temperature (고온에서 이중튜브의 열응력특성해석)

  • Kim, E.H.;Jang, J.H.;Park, S.P.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.19 no.7
    • /
    • pp.405-410
    • /
    • 2010
  • Double layered tube that has been used for transportation and oil piping system is occasionally exposed to elevated temperature. The change in stress state at elevated temperature is important for the safe design of double layered tube. In this study, the variation of stress state for hydroformed double layered tube of which inner tube is stainless steel and outer tube is mild steel has been analytically analyzed. To characterize the thermal stress at elevated temperature, analytical model to provide thermal stresses between outer tube and inner tube was developed by using theories of elasticity and Lame equation. The feasibility of analytical model is verified by finite element analysis using ANSYS $CLASSIC^{TM}$, commercially available code. The variation of thermal stress at various thickness combination of inner and outer tube has also been investigated by proposed analytical model.

Performance Evaluation on MEA with Double Layered Catalyst (이중구조 촉매층으로 구성된 MEA의 성능 평가)

  • Kim, Hong-Gun;Kwac, Lee-Ku;Kang, Sung-Soo;Kang, Young-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.55-58
    • /
    • 2006
  • An experimental study is performed to evaluate the performance and the efficiency by humidifying MEA and by making the double-layered catalyst in a fuel cell system which is taken into account the physical and thermal concept. An electrical output produced by PEMFC(Polymer Exchange Membrane Fuel Cell) is measured to assess the performance of the stack and the efficiency is also evaluated according to the different situation in which is placed with and without the humidification of MEA(Membrane Electrolyte Assembly). Subsequently, It is found that the measured values of MEA voltage and current are influenced by the MEA temperature, humidification, and the double-layered catalyst which gives more enhanced values to apply for electric units.

  • PDF

Manufacturing of High-Performance Double Layered Tube with Corrugated Internal Pattern via the Hydroforming Process (액압 성형을 이용한 내부복합파형 고효율 이중관 제조 기술)

  • Han, S. W.;Kim, D. Y.;Moon, Y. H.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.143-150
    • /
    • 2022
  • The purpose of this study was to investigate an innovative hydroforming process for the cost-effective manufacturing of double layered tube with circumferentially corrugated patterns. Conventional double pipe heat exchanger has relatively poor heat transfer efficiency because of the limited contact area resulting from the concentrically arranged simple cylindrical structure. As a promising alternative to enhance heat transfer efficiency, double layered tube with corrugated internal pattern was considered in this study. To fabricate corrugated inner tube, innovative tube hydroforming system was developed. The customized loading paths were established using the simulated forming pressure and contracting stroke at various bar diameters. Experimentally obtained cross-sectional profiles were analyzed to evaluate the reliability and applicability of the hydroformed tube with various patterns. The results demonstrate that the proposed hydroforming process can be a feasible alternative for manufacturing high-performance double-tube heat exchangers.

Effective Routing Schemes for Double-Layered Peer-to-Peer Systems in MANET

  • Kim, Ji-Hoon;Lee, Kwang-Jo;Kim, Taek-Hun;Yang, Sung-Bong
    • Journal of Computing Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.19-31
    • /
    • 2011
  • In this paper, we propose two new routing schemes for double-layered peer-to-peer systems; a shorter-lower mobility routing scheme and a reverse path routing scheme. The shorter-lower mobility routing scheme first chooses shortest routing paths among possible routing paths and selects the path associated with the relay peer who has lower mobility to improve the reliability of the system. The reverse path routing scheme carries out unicasting (instead of multicasting) based on the reverse path information that can be obtained during the initial file search to further reduce network traffic. The experimental results showed that a double-layered peer-topeer system with the proposed hybrid scheme improved the reliability of the system about 1.5% over the hop count scheme and reduced network traffic by about 0.5% compared to the hop count scheme.

Behavior of Water Vapor Permeability on Layered System

  • Oh, Ae-Gyeong
    • Fashion & Textile Research Journal
    • /
    • v.11 no.2
    • /
    • pp.359-362
    • /
    • 2009
  • This study investigates the behavior of water vapor permeability of a layered system to find out a comfortable combination of a layered system for outdoor activities and examines the water vapor permeability of various types of outdoor clothing fabrics. The layered system includes the base layer such as sportswool and polyester/cotton fabrics, the middle layer such as single and double sided fleece fabrics, and the shell layer such as polyurethane-coated, PTFE-laminated and microfiber fabrics in this experiment. Results show that the layered system was applied, it was working together as a whole having some influence on each other layer, though every layer offered varying degree of water vapor permeability. Water vapor permeability of layered system exactly followed the same trend as the shell layer, which is all vapor permeable water repellent fabrics as a single layer. The rate of water vapor transfer through a layered system is mainly related to the type of vapor permeable water repellent fabrics used for the shell layer.

System Identification for Structural Vibration of Layered Stone Pagoda System (적층식 석탑의 진동 시스템 인식)

  • Kim, Byeong Hwa
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.237-244
    • /
    • 2017
  • This study proposes a numerical model to explain the closely placed double modes in the vibration of a layered stone pagoda system. The friction surface between the stones is modelled as the Timoshenko finite element while each stone layer is modelled as a rigid body. It is assumed that the irregular asperity on the friction surface enables the stone to be excited. This results in the closely placed modes that are composed of natural modes and self-excited modes. To examine the validity of the proposed model, a set of modal testing and analysis for a layered stone pagoda mock-up model has been conducted and a set of closely placed double modes are extracted. Applying the extended sensitivity-based system identification technique, the various system parameters are identified so that the modal parameters of the proposed numerical model are the same with those of the experimental mock-up. For a horizontal impulse excitation, the simulated acceleration responses are compared with measurements.

Mechanical Behavior of Layered YSZ Thermal Barrier Coatings using Indentation Test (압입시험법에 의한 YSZ 층상 열차폐 코팅재의 기계적 거동)

  • Lee, Dong-Heon;Lee, Kee-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.396-403
    • /
    • 2011
  • In this study, we investigated the mechanical behaviors of layered thermal barrier coatings by indentations. Various single and double-layered thermal barrier coatings were deposited by air plasma spray process using different type of commercialized YSZ (Yttria stabilized zirconia) starting powders. Indentation stress-strain curve, load-displacement curve and hardness of the single and the double-layered thermal barrier coatings were obtained experimentally and analyzed. The indentation damages at the same loads were compared, and thus, the results depend on the structure of each coating. The result indicates improvement in damage resistances from tailoring of layered structures in the component of gas turbine system is expected.

A Study on the Performance Evaluation of Double-Layered Catayst MEA (이중촉매 MEA의 성능평가에 관한 연구)

  • Kim Hong-Gun;Kang Sung-Soo;Kwac Lee-Ku;Kang Young-Woo
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.50-59
    • /
    • 2006
  • An experimental and numerical study is carried out to investigate the performance and the efficiency humidifying Membrane Electrolyte Assembly and having the double-layered catalyst in a fuel cell system which is taken into account the physical and thermal concept. Based on the principals of the problem, the equation of electronic charge conservation equation, gas-phase continuity equation, and mass balance equation are used for the numerical calculation. A unit cell for $200cm^2$ MEA is assembled and measured for finding better operational situation. After finding the optimal condition, 10 cell stacked PEMFC is fabricated. For the performance evaluation, V-I and power curves are examined in detail by changing the condition of humidity, temperature, pressure, thickness of catalyst and oxidant. It is found that the power is maximized around 500W at 80A.

  • PDF

Coupled effects of electrical polarization-strain gradient on vibration behavior of double-layered flexoelectric nanoplates

  • Barati, Mohammad Reza
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.573-581
    • /
    • 2017
  • A vibrating double-layered nanoscale piezoelectric plate is developed accounting for the flexoelectricity and surface effects. The flexoelectricity is due to the coupling between electrical polarization and strain gradient. Applying Hamilton's principle, the governing equations and related boundary conditions are derived. Assuming suitable approximate functions, the governing equations are numerically solved for simply-supported and clamped boundary conditions. Obtained results indicate that both the flexoelectricity and surface effects possess notable impact on the vibration frequencies of the system. Only flexoelectricity yields a considerable difference between the present model and previous investigations on conventional piezoelectric nanoplates. Generally, a parametric study has been performed to examine the effects of surface elasticity, flexoelectricity, applied electric voltage, interlayer stiffness, geometrical parameters and boundary conditions on vibration frequencies of piezoelectric nanoplates.