• Title/Summary/Keyword: Double-Circuit

Search Result 531, Processing Time 0.023 seconds

Fault Location for Incomplete-Journey Double-Circuit Transmission Lines on Same Tower Based on Identification of Fault Branch

  • Wang, Shoupeng;Zhao, Dongmei;Shang, Liqun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1754-1763
    • /
    • 2017
  • This paper analyses the characteristics of incomplete-journey double-circuit transmission lines on the same tower formed by single-circuit lines and double-circuit lines, and then presents a fault location algorithm based on identification of fault branch. With the relationship between the three-phase system and the double-circuit line system, a phase-mode transformation matrix for double-circuit lines can be derived. Based on the derived matrix, the double-circuit lines with faults can be decoupled, and then the fault location for an incomplete-journey double-circuit line is achieved by using modal components in the mode domain. The algorithm is divided into two steps. Firstly, the fault branch is identified by comparing the relationships of voltage amplitudes at the bonding point. Then the fault location, on the basis of the identification result, is calculated by using a two-terminal method, and only the fault distance of the actual fault branch can be obtained. There is no limit on synchronization of each terminal sampling data. The results of ATP-EMTP simulation show that the proposed algorithm can be applied within the entire line and can accurately locate faults in different fault types, fault resistances, and fault distances.

Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines (전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Ahn, Yong-Jin;Kang, Sang-Hee;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.221-226
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.221-221
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation (낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준)

  • Woo, J.W.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • Lee, Won-Seok;Jung, Chang-Ho;Lee, Jun-Kyong;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.317-319
    • /
    • 2003
  • This paper describes an adaptive distance relay for double-circuit line protection with mutual impedance and fault resistance. Double-circuit lines have two operating condition; both lines of a double-circuit line are in operation and one line is switched-off and both ends of the line are grounded. For optimal distance protection, the trip region is calculated, which have respect to mutual impedance and fault resistance.

  • PDF

Design of Pixel Circuit of Micro LED Display with Double Gate Thin Film Transistors (더블 게이트 박막 트랜지스터를 활용한 Micro LED 디스플레이 화소 회로 설계)

  • Kim, Taesoo;Jeon, Jaehong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.50-55
    • /
    • 2022
  • Due to the wavelength shift problem of micro LED caused by the change of current density, the active matrix driving pixel circuit that is used in OLED cannot be applied to micro LED displays. Therefore, we need a gray scale method based on modulation of duration time of light emission. In this study, we propose the PWM-controlled micro LED pixel circuit based on CMOS thin film transistors (TFTs). By adopting CMOS inverter structure, we can reduce the number of storage capacitors from the circuit and make the operating speed of the circuit faster. Most of all, our circuit is designed to make operating speed of PWM circuit faster by adopting feedback effect through double gate TFT structure. As a result, it takes about 4.7ns to turn on the LED and about 5.6ns to turn it off. This operating time is short enough to avoid the color distortion and help the precise control of the gray scale.

Synchronization and Secure Communication in Hyper-chaos system using SC-CNN (SC-CNN을 이용한 하이퍼카오스 동기화와 비밀통신)

  • 배영철;임정석;황인호;김주완
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1175-1183
    • /
    • 2001
  • In this paper, we use hyper chaos circuit which is made through the phase differences which is generated during the process of weak-coupling of CNN between two and more chaos attractors. Notwithstanding the complexity of the hyper chaos, we could do the synchronization and according to it, Secure communication through this method coo]d be accomplished. On this research, we configurated 2-double scroll and 3-double scroll circuit ,not using Chua circuit, but SC-CNN(State-Controlled CNN) which is more flexible to configure the system.

  • PDF

Design and Analysis of Double-Layered Microwave Integrated Circuits Using a Finite-Difference Time-Domain Method

  • Ming-Sze;Hyeong-Seok;Yinchao
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.255-262
    • /
    • 2004
  • In this paper, a number of double-layered microwave integrated circuits (MIC) have been designed and analyzed based on a developed finite-difference time-domain (FDTD) solver. The solver was first validated through comparisons of the computed results with those previously published throughout the literature. Subsequently, various double-layered MIC printed on both isotropic and anisotropic substrates and superstrates, which are frequently encountered in printed circuit boards (PCB), have been designed and analyzed. It was found that in addition to protecting circuits, the added superstrate layer can increase freedoms of design and improve circuit performance, and that the FDTD is indeed a robust and versatile tool for multilayer circuit design.

The Synchronization of Hyper-chaos circuit using SC-CNN (SC-CNN을 이용한 하이퍼카오스 회로에서의 동기화)

  • 배영철;김주완
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.899-902
    • /
    • 2002
  • In this paper, we introduce a hyper-chaos synchronization method using State-Controlled Cellular Neural Network(SC-CNN). We make a hyper-chaos circuit using SC-CNN with the n-double scroll. A hyper-chaos circuit is created by applying identical n-double scrolls with weak coupled method, to each cell. Hyper-chaos synchronization was achieved using drive response synchronization between the transmitter and receiver about each state variable in the SC-CNN.

  • PDF