• 제목/요약/키워드: Double-Cantilever Beam

검색결과 120건 처리시간 0.028초

경량 재료를 이용한 DCB 시험편의 열림 모드에서의 파손 특성에 관한 연구 (A Study on Fracture Characteristics in Opening Mode of a DCB Specimen Using a Lightweight Material)

  • 김재원;조재웅
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2021
  • Recently, many structures using lightweight materials have been developed. This study was conducted by using Al6061-T6 and carbon fiber reinforced plastic (CFRP), two common lightweight materials. In addition, the failure characteristics of an interface bonded between a single material and a heterogeneous bonding material were analyzed. The specimens bonded with CFRP and Al6061-T6 were utilized by the combination of the heterogeneous bonding material. The specimens had a double cantilevered shape and the bonding between the materials was achieved by applying a structural adhesive. The experiments were conducted in opening mode: the lower part of the samples was fixed, while their upper part was subjected to a forced displacement of 3 mm/min by using a tensile tester. Under the tested amount of strength, energy release rate, and considering the specimens' fracture characteristics in opening mode, the specimen "CFRP-Al" presented the maximum stress, followed by "Al" and "CFRP". We can hence conclude that the inhomogeneous material "CFRP-Al" is useful for the construction of lightweight structures bonded with structural adhesive.

Adhesion Reliability Enhancement of Silicon/Epoxy/Polyimide Interfaces for Flexible Electronics

  • Kim, Sanwi;Kim, Taek-Soo
    • 마이크로전자및패키징학회지
    • /
    • 제19권3호
    • /
    • pp.63-69
    • /
    • 2012
  • Adhesion and mechanical reliability of silicon/epoxy/polyimide interfaces are critical issues for flexible electronics. Bonds between these interfaces are mainly hydrogen bonds, so their adhesion is weaker than cohesive fracture toughness and vulnerable to moisture. In order to enhance adhesion and suppress moisture-assisted debonding, UV/Ozone treatment and innovative sol-gel derived hybrid layers were applied to silicon/epoxy/polyimide interfaces. The fracture energy and subcritical crack growth rate were measured by using a double cantilever beam (DCB) fracture mechanics test. Results showed that UV/Ozone treatment increased the adhesion, but was not effective for improving reliability against humidity. However, by applying sol-gel derived hybrid layers, adhesion increase as well as suppresion of moisture-assisted cracking were achieved.

층간파괴인성치에 미치는 성형압력의 영향에 관한 연구 (A Study on the Effect of Molding Pressure on the Interlaminar Fracture Toughness)

  • 김형진;김재동;고성위
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1140-1147
    • /
    • 2001
  • This paper describes the effect of various molding pressure for Mode I. Mode II interlaminar fracture toughness of carbon fiber reinforced plastic composites by using double cantilever beam(DCB), end notched flexure(ENF) and end loaded split(ELS) Specimen. The value of $G_{IC}$, $G_{IIC}$ as a function of various molding pressure is almost same at 307, 431, 585 kPa, however it shows highest value under 307kPa molding pressure, The SEM photographs show good fiber distribution and interfacial bonding of composites when the molding pressure is the 307kPa.

  • PDF

CFRP 복합재료의 혼합모드 I/II 층간파괴인성치에 관한 연구 (A Study on Mixed Mode I/II Interlaminar Fracture Toughness of Carbon Fiber Reinforced Plastic Composites)

  • 김형진;박명일;김재동;고성위
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.48-54
    • /
    • 2000
  • This paper describes the effect of molding pressure, specimen geometries for Mixed Mode I/II interlaminar fracture toughness of carbon fiber reinforced plastic composites by using asymmetrical double cantilever beam(ADCB) specimen. The value of $G_{I/IIC}$ as a function of various molding pressure is almost same at 307, 431, 585 kPa. However it shows the highest value under 307 kPa molding pressure. The effect of $G_{I/IIC}$ due to the change of initial crack length of ADCB specimen was almost negligible in this study. It turns out that the condition for mix mode quasi-static crack growth in ADCB specimen is the ratio of the crack length to that of the specimen, i.e., ${\alpha}/L<0.4$.

  • PDF

알루미나 세라믹스의 R-curve 분석 (R-curve Analysis of Alumina Ceramics)

  • 김성진;손기선;이성학;백성기
    • 한국세라믹학회지
    • /
    • 제31권10호
    • /
    • pp.1099-1106
    • /
    • 1994
  • It is suggested that the microstructural toughening process in the initial rising portion of R-curves observed in polycrystalline alumina should be different from the grain bridging mechanism identified in the long crack regime. Microcracking in the advancing crack front seems to be a prerequisite for the development of unbroken bridging ligaments behind the crack tip. In order to test such a proposition, attempts were made to identify experimentally the presence of microcracks in the frontal zone of propagating cracks. In-situ observation is made of crack growth in a miniature double cantilever beam specimen of a average grain size of 10 ${\mu}{\textrm}{m}$ alumina. Presence of a few microcracks was identified in front of crack tip on the propagating crack plane. The R-curves were re-evaluated based on the observation.

  • PDF

접착이음의 계면균열에 대한 파괴인성 및 평가방법 (Mehods of Fracture Toughness and Evaluation for Interface Crack in Adhesively Bonded Joints)

  • 정남용
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.220-226
    • /
    • 1998
  • In this pater, a method of strength evaluation applying fracture mechanics in adhesively bonded joints of A1/A1 materials was investigated. Various adhesively bonded joints of double-cantilever beam with a interfacial crack in its adhesive layer were prepared for the fracture toughness test of comprehensive mixed mode conditions from nearly pure mode I to mode II. The experiment of fracture toughness was carried out under various mixed mode conditions with an interfacial crack and critical energy release rate, Gc by the experimental measurements of compliances was determined. From the results, fracture toughness on mixed mode with an interfacial crack is well characterized by strain energy release rate and a method of strength evaluation by the fracture toughness in adhesively bonded joints of A1/A1 materials was discussed.

  • PDF

이종 접합부재의 두께 변화에 따른 초음파 산란 보정에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Scattering Compensation Depending on Thickness Variations of Bonded Dissimilar Components)

  • 정남용
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.67-75
    • /
    • 2006
  • In this paper, the compensation of ultrasonic scattering on interface crack depending on thickness variations of A1/Epoxy bonded dissimilar components was applied to improve measuring accuracy by using ultrasonic attenuation coefficient. The optimum conditions of theoretical value and experimental measuring accuracy by the ultrasonic method in A1/Epoxy bonded dissimilar components have been investigated. From the experimental results, the measurement method of interfacial crack lengths by using ultrasonic attenuation coefficient was proposed and discussed. After the ultrasonic scattering compensation depending on thickness variations of bonded dissimilar components was carried out, the measuring accuracy of interfacial crack length was improved by 5%.

DCB 시험편의 평직 CFRP 복합재 층간파괴인성 및 AE 특성 평가 (The Evaluation of Interlaminar Fracture Toughness and AE Characteristics in a Plain Woven CFRP Composite with DCB Specimen)

  • 윤유성;권오헌
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.49-54
    • /
    • 2005
  • Recently, many kinds of advanced composite materials have been used in various industry fields. Among them, fabric CFRP composites are being used as primary structural components in many applications because of their superior properties. However, the complexity of the fabric structure makes understanding of their failure behavior very difficult. The mechanical strength and crack propagation of plain woven carbon fiber fabric laminate composites are examined by acoustic emission(AE) method. AE signals are acquired during the tensile test and fracture tests. Thus, the relationship between AE signal and mechanical behavior curves and crack extension length are shown. Also the interlaminar fracture toughness in terms of AE characteristics are discussed in viewpoint of crack propagation behavior.

SiC 휘스커 보강 알루미나 복합재료에서 Slow Crack Growth 현상의 직접관찰 연구 (In Situ Observation of Slow Crack Growth in a Whisker-Reinforced Alumina Matrix Composite)

  • 손기선;김우상;이성학
    • 한국세라믹학회지
    • /
    • 제33권2호
    • /
    • pp.203-213
    • /
    • 1996
  • In this study the subcritical crack growth behavior in an Al2O3-SiCw composite has been investigated using in situ fracture technique of applied moment double cantilever beam (AMDCB) specimens indside an SEM. This technique allows the detailed observation of whisker and grain bridging in the crack wake region. The experimental results indicated that the KI-a curve was deviated from the conventional powder law form and that the existed a region where the rate of microcrack growth was decreased with increasing the externally applied stress intensity factor. This behavior could be explained by arising crack growth resistance i.e. R-curve behavior which was associated with crack shielding due to whisker and grain bridging. The R-curve was also analyzed from the KI-a curve data in order to quantify the bridging effect in the Al2O3-SiCw composite.

  • PDF

CZM(Cohesive Zone Model)을 이용한 철도차량용 직물 복합재의 모우드 I 층간파괴의 해석적 연구 (Finite Element Analysis and Validation for Mode I Interlaminar Fracture behavior of Woven Fabric Composite For a Train Carbody Using CZM(Cohesive Zone Model))

  • 김승철;김정석;윤혁진;서승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.239-246
    • /
    • 2009
  • The Mode I interlaminar fracture toughness of woven fabric carbon/epoxy and glass/epoxy composites for a train carbody was measured and FEM analysis was conducted. The woven fabric epoxy composite manufactured by hand lay-up, has high stiffness and strength, good resistance for impact, fatigue, corrosion and in-plane failure. The DCB(Double Cantilever Beam) specimen made of woven fabric epoxy composite had the size of 180mm $\times$ 25mm $\times$ 5mm and the insert of 65mm. The Mode I interlaminar toughness of specimen was measured according to ASTM 5528-01. The crack propagation behavior of the DCB specimen was simulated using FEA with cohesive elements that model the adhesive layer between woven fabric plies.

  • PDF