• Title/Summary/Keyword: Double plate

Search Result 356, Processing Time 0.025 seconds

Structural Behavior of the RC Column-Steel Beam Joint with Band Plate (Band Plate로 연결된 RC기둥-철골보 접합부의 이력거동에 관한 실험연구)

  • Seo, S.Y.;Yi, W.H.;Lee, L.H.;Yoon, S.J.
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.213-221
    • /
    • 2002
  • This paper presents the experimental result of Reinforced Concrete column-steel beam joint connected by Band Plates(BP). Main parameters in the test are the shape of BP and thickness of plate. Ten interior and exterior RC column-steel beam joint specimens are designed. Cyclic loads are applied to the beam end of eight specimens (four interior specimens and four exterior specimens). To evaluate the cyclic effect, monotonic loads are acted for two specimens. All specimen showed similar failure pattern such as the plate of BP get torn after the large deformation. Even though the specimen with double cross type BP has lower strength than the specimen with single cross type BP, the energy dissipation capacity of the specimen turned out high. Thus, provided the strength of joint with double cross type to be designed to have suitable strength by increasing the thickness of plate, the joint system may show higher seismic capacity.

Development of Doubler Plate Design System for Ship Structure Subjected to In-plane Combined Loads and Lateral Pressure (면내조합하중과 횡압 하의 선박 이중판 설계시스템 구축)

  • Ham, Juh-Hyeok
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.146-152
    • /
    • 2019
  • A design system was developed for the doubler plate of a ship structure simultaneously subjected to in-plane loads and lateral pressure based on general dimensions and those of a representative ship structure. An equivalent design equation that considers various structural design parameters was derived by introducing the equivalent plate thickness theory, and the design of the doubler plate reinforcement of the ship structure was developed. A hybrid structural design system was established for a doubler plate simultaneously subjected to in-plane loads and lateral pressure consisting of two modules: an optimized design module and a double plate strength & design review module. The practical application of this design system was illustrated to show its usability. It was found that the design safety of the doubler plate was ensured, and this system could be used as an initial design guide to review the double plate reinforcement for a dent or corrosion of the ship plate members. Using the developed design system would make it possible to obtain a more reasonable doubler plate structure that considers the rational reinforcement of plate members of ship structures. In addition, a more reliable structural analysis using a strength evaluation process can be performed to verify the efficiency of the optimum structural design for the doubler plate structure.

Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube (표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구)

  • Chun, Tae-Kyu;Yang, Young-Joon;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

Safety Assessment of Double Deck Plate Wall Formwork against Lateral Pressure of Fresh Concrete (콘크리트 측압에 대한 더블 데크플레이트 벽체 거푸집의 안전성 평가)

  • Lee, Hye-Ji;Mun, Ju-Hyun;Yang, Keun-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.225-226
    • /
    • 2023
  • This study examined the lateral deformation of double deck plate wall formworks against the lateral pressure of fresh concrete and then compared with the construction specification.

  • PDF

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Investigation of shear lag effect on tension members fillet-welded connections consisting of single and double channel sections

  • Barkhori, Moien;Maleki, Shervin;Mirtaheri, Masoud;Nazeryan, Meissam;Kolbadi, S.Mahdi S.
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.445-455
    • /
    • 2020
  • Shear lag phenomenon has long been taken into consideration in various structural codes; however, the AISC provisions have not proposed any specific equation to calculate the shear lag ratio in some cases such as fillet-welded connections of front-to-front double channel sections. Moreover, those equations and formulas proposed by structural codes are based on the studies that were conducted on riveted and bolted connections, and can be applied to single channel sections whilst using them for fillet-welded double channels would be extremely conservative due to the symmetrical shape and the fact that bending moments will not develop in the gusset plate, resulting in less stress concentration. Numerical models are used in the present study to focus on parametric investigation of the shear lag effect on fillet-welded tension connection of double channel section to a gusset plate. The connection length, the eccentricity of axial load, the free length and the thickness of gusset plate are considered as the key factors in this study. The results are then compared to the estimates driven from the AISC-LRFD provisions and alternative equations are proposed.

Electric Resistance Double Spot Welding Process of Dissimilar Metal Plates of Steel and Aluminum by Using Heating Dies (가열금형을 사용하는 강철과 알루미늄 이종금속판재의 전기저항 이중스폿용접)

  • Kim, T.H.;Sun, Xiaoguang;Jin, I.T.
    • Transactions of Materials Processing
    • /
    • v.27 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • In this paper, a double spot welding process, utilizing electric resistance heating dies, is suggested for the spot welding of dissimilar metal plates for drawing and concurrent spot welding. This double welding process has two heating methods for the fusion welding at the interfacial zone between steel and aluminum plates, such as heating method by thermal conduction of electric resistance by welding current induced to heating dies, and heating method by electric resistance between contacted surfaces of two plates by welding current induced to copper electrode. This double welding process has welding variables such as each current induced in heating dies and in copper electrode, outer diameters of heating dies, and edge shape of copper electrode. Experiments for current conditions in welding process should be demanded in order to get successful welding strength. It was known that the welding strength could be reached to the value demanded on industry fields under such welding conditions as heating dies of outer ring dia.12mm contacted on steel plate, as heating dies of outer ring dia. 14mm contacted on aluminum plate, and as copper electrode of dia. 6.0mm, and as 3 times continuous heating method by $1^{st}$ current of 11 kA(9cycle), $2^{nd}$ current 11 kA(60cycle), $3^{rd}$ current 7 kA(60cycle) applied in steel heating dies and copper electrodes, flat edge of copper electrode, for double spot welding process of dissimilar metal plates of steel and aluminum of 1.0 mm thickness.

Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture (하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구)

  • Lee, Won;Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.