• Title/Summary/Keyword: Double cam

Search Result 53, Processing Time 0.026 seconds

Motion Analysis of the Eccentric Driving Cam on Double Raschel Machine (더블 라셀기 편심캠 구동장치의 운동해석)

  • 권상석;김환국;김영규;전두환
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.147-150
    • /
    • 2001
  • 더블 라셀기(Double Raschel Machine)는 레이스와 메리야스 직물 등을 생산하기 위한 섬유기계로써 대부분의 섬유기계들이 그러하듯이 수많은 링크와 기구들로 이루어져 있다. 따라서, 이러한 복잡한 링크들로 이루어진 기계 구조물을 국산화 개발하기 위해서는 설계오류에 따른 수많은 시행착오와 시간이 소요된다. (중략)

  • PDF

Full mouth implant rehabilitation with double scanning of provisional restoration (임시치아 double scanning을 이용한 전악 임플란트 수복 증례)

  • Yang, Dong-Hun;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.252-257
    • /
    • 2014
  • It is important to produce a provisional restoration reflecting the patient's jaw relation, occlusal plane, lip support, shape of teeth, and occlusion type for fully edentulous patients before making a definite prosthesis. The patient introduced in this study showed bad prognosis of remained tooth after severe periodontal diseases. Therefore, remaining teeth were extracted and replaced with dental implants. Provisional restorations were fabricated and the the patient's vertical and horizontal jaw relationship, occlusal plane, amount of overjet and overbite, size of teeth, and length of anterior tooth were recorded. Provisional restorations were scanned and CAD/CAM techniques were used to fabricate a monolithic zirconia bridge, which contour is identical with the provisional restorations. The patient was satisfied with the treatment results on functional, esthetic aspects and the prosthesis retained stable during the four-month clinical observation period.

A Study on 5-Axis Machining of Roller Gear Cam for Rotary Table (로터리테이블용 롤러기어캠의 5-축 가공에 관한 연구)

  • Cho, Hyun-Deog;Park, Jong-Bae;Shin, Yong-Bum;Lee, Kang-Su
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.127-134
    • /
    • 2017
  • A rotary table is a positioning device used in metalworking for the multiple axes of machine tools, and the utilization trend is increasing with machining efficiency. In the construction of a rotary table, the core technology is a power transfer unit that drives the table, typically a gear type and a roller gear cam type. As the rollers installed on the turret column have rolling movement on the contact surface of the roller gear cam, the roller gear cam type has the advantage of low wear, high load, and fast driving. Therefore, it is currently being replaced by a roller gear cam type. In this study, we researched a 5-axis machining method for the roller gear cam on a rotary table and a new method of applying double roller gear cam curve to reduce the noise and shock between the roller and the cam surface. We implemented the 5-axis machining process in this study using software to generate NC-code and machined the roller gear cams using a Mazak Integrex-200IV. We found that the roller gear cam and turret were able to identify mutual touch status and the noise from the operation of the roller gear cam was substantially reduced.

Triangular Mesh Generation on Places or Surfaces by a New Looping Method (새로운 분할법에 의한 평면 및 곡면의 삼각형 요소망 자동생성)

  • 이민철;전만수;임우섭
    • Korean Journal of Computational Design and Engineering
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 1999
  • A general approach to automatic generation of triangular meshes on three-dimensional surfaces is presented in this paper. The approach, developed with emphasis on program generality and interface with CAD/CAM systems, is based on the double mapping method and the looping method. The double mapping method is introduced and anew splitting scheme is proposed for the looping method employed for triangular mesh generation on the parametric domain. Several application examples are given.

  • PDF

Study on The Strip Layout Design of LCD Shield Case Using 3D CAD/CAM (3차원 CAD/CAM을 활용한 액정용 실드 케이스의 스트립 레이아웃 설계에 관한 연구)

  • Choi, Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.979-983
    • /
    • 2007
  • In this thesis, a strip layout drawing of LCD S/C (shield case) was prepared. In the press die, strip layout drawing is a major factor that decides the mass production of a product. The 3D CAD/CAM system was applied for the easy correction of the interference factor with other parts to be mounted. The material use ratio was enhanced to 60.17% by optimizing the blank layout and strip layout in double width array. Furthermore, the flatness of the product was made to fit the requirements by adding the bidding process intensively on the notching part where the occurrence of the change in shape is expected owing to the thin material. For the 3D CAD/CAM software, Unigraphics NX3.0 was used. The strip layout drawing was prepared in 12 processes.

  • PDF

Identification of a Technique Optimized for the Isolation of Spermatogonial Stem Cells from Mouse Testes

  • Han, Na Rae;Park, Hye Jin;Lee, Hyun;Yun, Jung Im;Choi, Kimyung;Lee, Eunsong;Lee, Seung Tae
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.327-336
    • /
    • 2018
  • To date, there are no protocols optimized to the effective separation of spermatogonial stem cells (SSCs) from testicular cells derived from mouse testes, thus hindering studies based on mouse SSCs. In this study, we aimed to determine the most efficient purification method for the isolation of SSCs from mouse testes among previously described techniques. Isolation of SSCs from testicular cells derived from mouse testes was conducted using four different techniques: differential plating (DP), magnetic-activated cell sorting (MACS) post-DP, MACS, and positive and negative selection double MACS. DP was performed for 1, 2, 4, 8, or 16 h, and MACS was performed using EpCAM ($MACS^{EpCAM}$), Thy1 ($MACS^{Thy1}$), or GFR ${\alpha}1$ ($MACS^{GFR{\alpha}1}$) antibodies. The purification efficiency of each method was analyzed by measuring the percentage of cells that stained positively for alkaline phosphatase. DP for 8 h, $MACS^{Thy1}$ post-DP for 8 h, $MACS^{GFR{\alpha}1}$, positive selection double $MACS^{GFR{\alpha}1/EpCAM}$, and negative selection double $MACS^{GFR{\alpha}1/{\alpha}-SMA}$ were identified as the optimal protocols for isolation of SSCs from mouse testicular cells. Comparison of the purification efficiencies of the optimized isolation protocols showed that, numerically, the highest purification efficiency was obtained using $MACS^{GFR{\alpha}1}$. Overall, our results indicate that $MACS^{GFR{\alpha}1}$ is an appropriate purification technique for the isolation of SSCs from mouse testicular cells.

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.

Shear Bond Strength of Zirconia and Ceramics according to Dental Zirconia Surface Treatment (치과용 지르코니아 표면처리방법에 따른 지르코니아와 전장용 도재의 결합강도 관찰)

  • Lee, Gwang-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • Purpose: The dental CAD / CAM system has been popular with the development of the digital dental industry. Zirconia is a typical material in dental CAD / CAM systems. Zirconia crowns are classified into single layer and double layer. This study is about the double layer crown of zirconia. The surface roughness, bond strength and fracture patterns of the zirconia surface were observed. Methods: Zirconia blocks were cut using a low speed cutter. Sintered to form a plate shape (6mm × 6mm × 3mm). The prepared specimens were surface treated in four ways. Surface roughness and bond strength were measured. And the fracture pattern was observed. Results: Result of surface treatment of zirconia. The surface roughness test results were as ET 2.87 ㎛, ST 2.67 ㎛, LT 2.44 ㎛, AT 2.41 ㎛, CN 2.08 ㎛ order. Bond Strength results were as LT 25.09 MPa, AT 23.27 MPa, ST 21.27 MPa, ET 21.09 MPa, CN 16.12 MPa order. Fracture patterns showed cohesive failure of 25-50% of the bond area. Conclusion: Surface roughness, bond strength and fracture pattern of the zirconia surface were observed. Etching the surface treatment of zirconia materials has been shown to affect the surface roughness. Zirconia special binder treatment has been shown to affect the bond strength improvement.

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

A Weak-lensing Study of the Double Radio Relic Galaxy Cluster Abell 1240

  • Cho, Hyejeon;Jee, Myungkook James;Finner, Kyle
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.34.1-34.1
    • /
    • 2021
  • Abell 1240 is a merging galaxy cluster hosting prominent, symmetric double radio relics. To constrain its merging history, we provide the first weak-lensing analysis of the dark matter distribution of the Abell 1240 field with Subaru/Suprime-Cam observations after robustly addressing instrumental systematics. We also investigate the cluster galaxy distributions, combining our new MMT/Hectospec observations and the spectroscopic redshifts from the literature. Both weak-lensing mass reconstruction and galaxy distribution show that Abell 1240 consists of two subclusters stretched north to south between the double radio relics. We quantify the significance of the substructures and present their mass estimates. Finally, we discuss a merging stage of Abell 1240 with the current weak-lensing results and the radio relic priors.

  • PDF