• Title/Summary/Keyword: Double Inlet

Search Result 113, Processing Time 0.027 seconds

Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger (Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구)

  • ANCHEOL CHOI;SEONGWOO LEE;IK HO SHIN;SUNGWOONG CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.

Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case (십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례)

  • Kim, Dae-Yeon;Jo, Seong-Rae;Park, Seong-Dal;Jeong, Hyeon-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

A Comparison with CFD Simulation and Experiment for Steam-methane Reforming Reaction in Double pipe Continuous Reactor (이중관형 연속 반응기에서 수증기-메탄 개질반응의 실험 및 CFD 시뮬레이션)

  • Shin, Dong-Woo;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.226-236
    • /
    • 2013
  • The heat distribution and internal flow from the efficiency of actual reformer and specification variation, using the computer simulation and experiment about the steam methane reforming reaction which uses the high temperature reformer. Reaction model from steam refoemer uses the steam response model developed by Xu & Froment.As result we supposed the chemical react Steam Reforming(SR), Water Gas Shift(WGS), and Direct Steam Reforming(DSR) from the inner high temperature reformer dominates the response has dissimilar response. According to result of steam methane reforming reaction exam using high temperature reformer, we figured out when Steam Carbon Ratio(SCR) increase, number of hydrogen yield increases but methane decreases. When comparing and examining between design with one inlet and two inlet, result came out one inlet design is more outstanding at thermal distribution and internal flow, hydrogen yield in one inlet design than two inlet design.

An optimum design study of interlacing nozzle by using Computational Fluid Dynamics

  • Juraeva Makhsuda;Ryu Kyung-Jin;Kim Sang-Dug;Song Dong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.05a
    • /
    • pp.395-397
    • /
    • 2006
  • Air interlacing serves to protect the yarn against damage, strengthens inter-filament compactness or cohesion, and ensures fabric consistency. The air interlacing nozzle is used to introduce intermittent nips to a filament yarn so as to improve its performance in textile processing. The effect of various interlacing nozzle geometries on the interlacing process was studied. The geometries of interlacing nozzles with single or multiple air inlets located across the width of yarn channels are investigated. The basis case is the yarn channel, with a perpendicular main air inlet in the middle. Other cases have main air inlets, slightly inclined double sub air inlets, The yarn channel cross sectional shapes are either semicircular or rectangular shapes. The compressed impinging jet from the main air inlet hole hits the opposing bottom wall of the yarn channel, is divided into two branches, joins with the compressed air coming out from sub air inlet at the bottom and creates two free jets at both ends of the yarn channel. The compressed air movement in the cross-section consists of two opposing directional vortices. The CFD-FASTRAN flow parallel solver was used to perform steady simulations of impinging jet flow inside of the interlace nozzles. The vortical structure and the flow pattern such as pressure contour, particle traces, velocity vector plots inside of interlace nozzle geometry are discussed in this pater.

  • PDF

Experimental Study on Turbulent Characteristics of Swirling Flow in 90$^{\circ}$ Degree Circular Tube by Using a PIV Technique (PIV기법을 이용한 원헝단면을 갖는 90$^{\circ}$ 곡관내의 선회유동의 난류특성에 관한 실험적 연구)

  • Chang Tae-Hyun;Lee Hae Soo
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.2
    • /
    • pp.38-46
    • /
    • 2003
  • An experimental investigation was performed to study the turbulent characteristics of swirling flow a 90$^{\circ}C$ circular tube for Re = 10,000, 15,000 and 20,000. 2D-PIV(Particle Image Velocimetry)technique was employed to measure the fluctuation velocity field. The results include spatial distributions of mean velocity vectors, turbulence intensity and turbulence kinetic energy. The axial and radial turbulence intensities, and kinetic energy profiles show double-peak structures in the inlet region of the 90 degree bend and the profiles are disappeared along the test tube with decaying the swirl intensity.

  • PDF

Thiobacillus ferrooxidans 생물막과 화학적 방법에 의한 항화수소 처리 공정 개발

  • Jeong, Seung-Ho;Jang, Yeong-Seon;Cha, Jin-Myeong;Kim, Tae-Won;Lee, Gwang-Yeon;O, Min-Ha;Park, Don-Hui
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.423-426
    • /
    • 2002
  • A novel process for $H_2S$ gas treatment has been introduced, based on the combined action of a chemical absorption step and a biological step involving the biocatalytic activity of the bacterium Thiobacillus ferrooxidans. The aim of this study is the development of a process for $H_2S$ elimination from gas streams based on that chemical/biological method. The immobilized biomass reactor/chemical adsorption system is suitable for application of the removal of $H_2S$. A double stage reactor was used for the experimental work. The removal efficiencies of over 99% were observed in the range of inlet $H_2S$ concentration from 200 to 1,000ppm. The novel process showed the stable elimination efficiencies of over 95% under the retention time range from 20 to 40sec at the 1,000ppm of $H_2S$ inlet concentration.

  • PDF

Effect of Pressure and Stoichiometric Air Ratio on NOx Emissions in Gas-Turbine Dump Combustor with Double Cone Burner (이중원추형 모형연소기에서 압력과 공기비에 따른 NOx 배출특성)

  • Nam, Dong-Hyun;Nam, Hyun-Su;Han, Dong-Sik;Kim, Gyu-Bo;Cho, Seung-Wan;Kim, Han-Suk;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.251-257
    • /
    • 2012
  • This work presents an experimental investigation of NOx emissions according to inlet air temperature (550-660 K), stoichiometric air ratio (${\lambda}$, 1.4-2.1), and elevated pressure (2-5 bar) in a High Press Combustor (HPC) equipped with a double cone burner, which was designed by Pusan Clean Coal Center (PC3). The exhaust-gas temperature and NOx emissions were measured at the end of the combustion chamber. The NOx emissions generally decreased as a function of increasing ${\lambda}$. On the other hand, NOx emissions were influenced by ${\lambda}$, inlet air temperature and pressure of the combustion chamber. In particular, when the inlet air temperature increased, the flammability limit was extended to leaner conditions. As a result, a higher adiabatic temperature and lower NOx emissions could be achieved under these operation conditions. The NOx emissions that were governed by thermal NOx were greatly increased under elevated pressures, and slightly increased at sufficiently low fuel concentrations (${\lambda}$ >1.8).

Application of Generalized Experimental Data Correlation in Centrifugal Compressor Design (원시험 데이터 일반화를 적용한 원심압축기 설계)

  • Cho, Gyu-Sik;Kim, Jin-Han;Yang, Soo-Seok;Lee, Dae-Sung;Mileshin, Victor I.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.38-43
    • /
    • 2000
  • Recently, KARI(Korea Aerospace Research Institute, Korea) and CIAM(Central Institute of Aviation Motors, Russia) have made an effort in developing a centrifugal compressor for a small gas turbine engine as part of a collaboration program. This compressor has been designed as a sub-component for an axial-centrifugal compression system for a small turbo-shaft engine aiming adiabatic efficiency higher than 0.81. The geometrical design requirement imposes restrictions to have high inlet hub-to-tip ratio and inlet swirl flow. In this study, the compressor has been designed using the generalized experimental data established from those compressors having pressure ratio of 3.7 to 5. From this generalized empirical correlation, desirable values of design parameters could be obtained. Subsequently, quasi-3D and 3D viscous flow analyses have been performed to ensure the adopted methodology. It is expected that the centrifugal compressor provides total pressure ratio of 4.89, corrected mass flow-rate of 1.64kg/sec, and adiabatic efficiency of 0.815 with inlet hub-to-tip ratio of 0.641. These relatively high total pressure ratio and inlet hub-to-tip ratio are the main distinctive features in this design. Besides, one of the main features of this centrifugal compressor is the adoption of a double-row bladed diffuser to effectively decelerate the transonic flow leaving the impeller. The compressor has been manufactured and will be tested in the near future.

  • PDF

Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan (주기적 선회실속이 발성하는 축류홴의 3차원 유동구조)

  • Kang, Chang Sik;Shin, You Hwan;Kim, Kwang Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

Performance Analysis of a Vertical Double Pipe Heat Exchanger for Latent Heat Storage (수직이중관형 잠열축열장치의 성능분석)

  • Kim, Young-Bok;Song, Hyun-Kap
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.38-46
    • /
    • 1990
  • For the optimal design and the efficient operation of the double pipe type latent heat storage equipment, the effect of the parameters of the system were analysed. The statistical analysis showed that the theoretical and the experimental results of the volume change rate and the temperature variations were well agreed. Therefore, this theoretical model is reasonable to analyze two dimensional moving boundary problems. In the analysis of the effects of the parameters, the heat extraction fraction and the water outlet temperature of the system as function of the time were analysed depending on the initial temperature of PCM, water inlet temperature, water mass flow rate and the dimension of the inner tube.