• Title/Summary/Keyword: Double CAM

Search Result 53, Processing Time 0.022 seconds

Optimum Design of Beating Cam for High Speed Rapier Loom (고속 래피어 직기용 바듸침 캠의 최적설계)

  • Kim, Jong-Su;Kim, Dae-Won
    • 연구논문집
    • /
    • s.28
    • /
    • pp.89-100
    • /
    • 1998
  • This paper deals with the design and analysis of a beating cam. The beating device of a high speed rapier loom, weaving fabric by completion of warp-weft patterns, is driven by double cam type on the same axis. As the double cam, coupled with two cams, performs the mutual conjugate motion, the double cam must be very preciously designed for smooth. For the shape design of a double cam, an instant velocity center method is proposed. This method can determine the cam profile from the contact conditions of the cam and roller follower and the velocity relationships at the instant velocity center. And the practical applicability was verified by developing “DISKCAM of a CAD program. As the results in this paper, the shapes of two cams, which are in the conjugate motion, are designed by instant velocity center method. We applied 8-order polynominals for the beating as displace¬ment curves for shape determination of double cams. The data of displacement, velocity, and acceleration of beating cam can be used adjust in accurate operation and to develope an advanced beating device.

  • PDF

Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD/CAM double scanning technique (중증도의 치아 마모 환자를 구내 스캐너와 이중스캔을 이용해 수복한 완전구강회복 증례)

  • Yoon, Se-Na;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.

A Study on the Design of Testable CAM using MTA Code (MTA 코드를 적용한 Testable CAM 설계에 관한 연구)

  • 정장원;박노경;문대철
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.48-55
    • /
    • 1998
  • In this work, the testable CAM(Content Addressable Memory) is designed to perform the test effectively by inserting the ECC(Error Checking Circuit) inside the CAM. The designed CAM has the circuit which is capable of testing the functional faults in read, write, and match operations. In general the test circuit inserted causes the increase of total circuit area, Thus this work, utilizes the new MTA code to reduce the overhead of an area of the built-in test circuit which has a conventional parallel comparator. The designed circuit was verified using the VHDL simulator and the layout was performed using the 0.8${\mu}{\textrm}{m}$ double metal CMOS process. About 30% reduction of a circuit area wad achieved in the proposed CAM using the XOR circuit

  • PDF

A Development of Single Action Press Robot (프레스 단동로봇의 개발)

  • 허성창;황병복
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

Development of Simulation Program of Double Cam Driving System for Rapier Loom (래피어 직기용 더블 캠 구동 시스템의 시뮬레이션 프로그램 개발)

  • Kim, Jong-Su
    • 연구논문집
    • /
    • s.29
    • /
    • pp.111-121
    • /
    • 1999
  • Weft insertion and Beating mechanism which weaves fabric with completion the pattern of warp yarn and weft yarn in the high speed rapier loom is driven by cam operating method. This mechanism has 4 cams on the coaxial line for driving. These cams form a pair by two. and perform a conjugate motion with each other. By this reason, it is necessary for two pairs to realize the synchronized motion through exact and optimal design. From this viewpoint, to analysis the whole cams' movement and to realize the high speed of rapier loom, I tried to develop the computer aided simulation program. In this study, I would like to introduce the simulation program about above-mentioned 4 kinds of cam mechanism which can display the profiles of 2 pairs of cam mechanism not to speak of mutual relationships of their movement on the monitor.

  • PDF

Increased Expression of Epithelial Cell Adhesion Molecule (EpCAM) in Rat Hepatic Tumors Induced by Diethylnitrosamine

  • Kang, Jin Seok
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3627-3630
    • /
    • 2012
  • The epithelial cell adhesion molecule (EpCAM) is a pan-epithelial differentiation antigen that is expressed on almost all carcinomas. However, a role in rat liver carcinogenesis has never been reported previously. Thus, its expression was investigated herein in rat liver tumors induced by diethylnitrosamine (DEN). Twenty male 5-week-old F344 rats were used in this experiment. Mini-osmotic pumps containing doses of 47.5 mg of DEN were inserted into the abdominal cavity of each animal to initiate liver carcinogenesis. All animals were sacrificed at 26 weeks after DEN treatment. At necropsy, hepatic masses were processed for histopathological examination, which revealed forty-four hepatocellular adenomas (HCAs) and twenty hepatocellular carcinomas (HCC). Tumors were immunohistochemically analyzed for EpCAM, proliferating cell nuclear antigen (PCNA) and co-localization of the two. EpCAM expression was mainly detected in hepatic tumor cells, showing a cytoplasmic staining pattern. However, expression was also slightly observed in normally-appearing surrounding hepatic cells. PCNA expression was highly detected in tumor cells, showing nuclear staining. Double staining of EpCAM and PCNA in tumors showed many cells with co-localization. Taken together, EpCAM and PCNA expression were increased in DEN-induced tumors and many tumor cells showed co-expression. It is suggested that EpCAM may increase during DEN-induced tumors, possibly associated with cell proliferation.

DIFFERENTIAL TIME-SERIES CCD PHOTOMETRY OF BL CAMELOPARDALIS (BL Camelopardals의 CCD 시계열 차등광전측광)

  • 김철희;심은정
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.241-254
    • /
    • 1999
  • Differential time-series observations of BL Camelopardalis classified as a double mode SX Phoenicis type variable were secured with a charge coupled device. The observed photometric data was reduced using the IRAF Package and the differential magnitudes were obtained through aperture photometry. The periods of BL Cam were analyzed with the Generalized Least-Square Method by Vanicek (1971) and the Fourier Decomposition Method. It was found that the first and second period of BL Cam were 0.0391 day respectively which lead the period ratio of P1/P0=0.81. This period ratio is much different from 0.78 determined by other investigators and also much more larger than that of other double-mode SX Phe type variables. In addition, this period ratio is much different from the value expected from the relation between the metallicity and period ratio. From these results, it can be confirmed that BL Cam is the most extreme case among all double-mode SX Phe type variables.

  • PDF

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.