Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발 (Development of Web-based Dosimetry Calibration Program for High Energy Radiation)

  • 신동오;신동호;김성훈;박성용;서원섭;안희경;강진오;홍성언
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.116-124
    • /
    • 2005
  • 고 에너지 광자선과 전자선의 흡수선량 결정에 대한 표준측정법은 공기커마 교정인수를 바탕으로 한 방법이 널리 사용되고 있으나 복잡한 수식과 물리적인자의 불확실성 등으로 정확도 향상에 한계가 있다. 따라서 최근 국제원자력기구와 미국의학물리학회에서 물 흡수선량을 기반으로 표준측정법을 개발하였다. 본 연구는 국제원자력기구의 IAEA TRS-398 과 미국의학물리학회의 AAPM 7e-51 물 흡수선량 표준측정법에 대한 인터넷을 기반으로 하는 선량교정 프로그램을 개발하였다. 이 프로그램은 인터넷 온라인상에서 사용할 수 있도록 C$\#$ 언어를 사용하여 각각의 표준측정법의 절차에 따라 사용자의 편의를 고려하여 개발하였다. 사용자는 인터넷을 통해 기준점에서의 두 가지 절차서에 따른 물 흡수선량을 비교할 수 있으며, 국내 각 기관에서 수행된 선량교정의 추세를 이해하고 보다 쉽게 관리할 수 있게 하였다. 웹 기반 데이터베이스를 이용하여 차후 국내 실정에 적합한 물 흡수선량 표준에 기반을 둔 표준측정법을 개발하는데 기여할 것으로 기대된다

  • PDF

방사선 내부흡수선량의 의학적 적용 (Medical Application of Radiation Internal Dosimetry)

  • 김경민;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교 (Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams)

  • 박창현;신동오;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.249-258
    • /
    • 2003
  • 흡수선량 측정의 정확성을 향상시키기 위하여 기존의 공기커마 혹은 조사선량 표준에서 물 흡수선량 표준으로 선량측정의 패러다임이 변화하고 있다. 본 연구는 기존의 프로토콜에서 물 흡수선량 기반의 프로토콜로의 전환을 모색하는 입장에서 현재 임상에서 널리 사용하고 있는 IAEA TRS­277과 물 흡수선량 표준에 토대를 두고 있는 IAEA TRS­398 및 AAPM TG­51 프로토콜에 대하여 동일한 기준깊이에서 물 흡수선량을 측정하여 상호 비교하였다. Varian 2100 C/D 선형가속기로부터의 세 종류의 전자선 에너지에 대해 PTW 30002 원통형 이온함과 Markus 및 Roos 평행평판형 이온함을 사용하여 측정하였고 $^{60}$Co에서의 공기커마 및 물 흡수선량 교정정수는 식품의약품안전청으로부터 받아 사용하였다. 공기커마 표준에 기반한 프로토콜과 물 흡수선량 표준에 기반한 프로토콜간에는 2% 이내의 차이를 보임으로써 사용자 기관에서는 자체적인 확인을 거쳐 공기커마 기반의 프로토콜에서 물 흡수전량 기반 프로토콜로의 전환을 적극 검토해 볼 필요가 있다. 물 흡수선량 기반의 프로토콜간에는 원통형 이온함의 경우 0.5% 이내에서 잘 일치하였고 평행평판형 이온함의 경우에도 고 에너지 전자선을 이용한 교차 교정을 하면 0.7% 이내에서 잘 일치하였다. 사용한 모든 프로토콜과 전자선 에너지에 대해 원통형 이온함과 평행평판형 이온함간에는 2% 이내의 차이를 보였으나 선량측정의 정확성을 향상시키기 위해 물 흡수선량 표준에 기반한 프로토콜의 권고에 따라서 하한에너지 이하의 전자선의 경우는 원통형 이온함 대신에 평행평판형 이온함을 사용함이 타당하다고 사료된다.

  • PDF

동위원소 치료 관련 방사선 흡수선량평가 (Radiation Dosimetry for Radionuclide Therapy)

  • 김은희
    • 대한핵의학회:학술대회논문집
    • /
    • 대한핵의학회 2001년도 제40차 춘계학술대회 및 연수교육
    • /
    • pp.4-10
    • /
    • 2001
  • The radionuclide therapy is a protocol for tumor control by administering radionuclides as the cytotoxic agents. Radionuclides concentrated at the site of cancerous lesion are expected to kill the cancerous cells with minimal injury to the normal tissue. The efficacy of every radionuclide treatment can be evaluated by examining the toxicity to the lesion differentiated from that to the normal tissue. Radiation dosimetry is the procedure of quantitating the energy absorbed by target volumes of interest. Dosimetric information plays an indicator of the expected radiation damage and thus the therapeutic efficacy. This paper summarizes the dosimetric aspects in radionuclide therapy in terms of radionuclides of use, radiation dosimetry methodology and considerations for each treatment in practical use.

  • PDF

Cs-137 감마선의 선량측정을 위한 TRS-398 선질인자 결정에 관한 연구 (Determination of TRS-398 Quality Factors for Cs-137 Gamma Rays in Reference Dosimetry)

  • 강상구;이동주;강영록;김정기;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.123-127
    • /
    • 2014
  • Cs-137 방사선 조사기는 방사선생물 연구 분야에서 시료에 방사선 조사장치로 널리 사용되고 있다. 이러한 방사선 조사기 사용에 있어 시료에 조사되는 흡수선량의 평가는 향상된 연구 결과를 얻기 위하여 중요하다. 국제원자력기구의 TRS-277 또는 TRS-398 같은 선량측정 프로토콜은 이러한 목적에 적합하다. 그러나 현재 가장 실용적인 선량측정 프로토콜로 알려진 TRS-398의 경우에 Cs-137 선원에 대한 선질인자가 제공되지 않는 단점이 있다. 본 연구에서는 이전에 보고된 고에너지 방사선치료용 광자선에 대한 계산방법을 이용하여 Cs-137 선원의 선질인자를 결정하였으며 15종의 파머형 전리함에 대하여 선질인자를 결정하였다. 결과로서 대상전리함에 대한 Cs-137 선원에서 선질인자는 0.998에서 1.002 범위를 보였다. 이 결과는 Cs-137 선원을 사용하는 분야에서 물흡수선량 측정과 선량계의 교정에 유용하게 사용할 수 있을 것으로 본다.

kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정 (Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers)

  • 이강규;임천일;장세경;문성록;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.53-61
    • /
    • 2005
  • 본 연구에서는 kV X-선에 대하여 원통형전리함의 선질인자를 몬테칼로 계산과 측정으로 결정하였다. 대상 X-선은 KFDA에 설치되어 있으며 에너지스펙트럼과 선질이 명시된 $60\~300kV$ 범위의 X-선(ISO-4037)이었으며, 전리함은 PTW N23333과 N30001이었다. 이론적 계산과 몬테칼로 계산으로 구한 공기커마와 공동의 흡수선량으로부터 IAEA프로토콜의 $R_{\mu}$$R_{Q,Q_{0}}$인자를 결정하였다. 두 전리함의 반응 범위는 $80\~250kV$ 영역에서 모두 $\pm3\~4\%$를 보였으나, N30001 전리함의 경우에 $110\~300kV$ 영역에서 $\pm1.7\%$로서 평탄한 특성을 보였다. 본 연구로부터 kV X-선에 대한 선량평가에 대하여 고찰할 수 있었으며, 프로토콜의 적용을 위하여 에너지의존성의 평가가 중요함을 알 수 있었다.

  • PDF

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.