Impact of 0.35 T Magnetic Field on Dose Calculation for Non-small Cell Lung Cancer Stereotactic Radiotherapy Plans

  • Jaeman Son;Sung Young Lee;Chang Heon Choi;Jong Min Park;Jung-in Kim
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.117-123
    • /
    • 2023
  • Background: We investigated the impact of 0.35 T magnetic field on dose calculation for non-small cell lung cancer (NSCLC) stereotactic ablative radiotherapy (SABR) in the ViewRay system (ViewRay Inc.), which features a simultaneous use of magnetic resonance imaging (MRI) to guide radiotherapy for an improved targeting of tumors. Materials and Methods: Here, we present a comprehensive analysis of the effects induced by the 0.35 T magnetic field on various characteristics of SABR plans including the plan qualities and dose calculation for the planning target volume, organs at risk, and outer/inner shells. Therefore, two SABR plans were set up, one with a 0.35 T magnetic field applied during radiotherapy and another in the absence of the field. The dosimetric parameters were calculated in both cases, and the plan quality indices were evaluated using a Monte Carlo algorithm based on a treatment planning system. Results and Discussion: Our findings showed no significant impact on dose calculation under the 0.35 T magnetic field for all analyzed parameters. Nonetheless, a significant enhancement in the dose was calculated on the skin surrounding the tumor when the 0.35 T magnetic field was applied during the radiotherapy. This was attributed to the electron return effect, which results from the deviation of the electrons ejected from tissues upon radiation due to Lorentz forces. These returned electrons re-enter the tissues, causing a local dose increase in the calculated dose. Conclusion: The present study highlights the impact of the 0.35 T magnetic field used for MRI in the ViewRay system for NSCLC SABR treatment, especially on the skin surrounding the tumors.

토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석 (Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy)

  • 조강철;김주호;김훈겸;안승권;이상규;윤종원;조정희;이종석;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권4호
    • /
    • pp.327-335
    • /
    • 2013
  • 토모테라피를 이용한 3D-CRT의 임상적 적용 사례를 Helical mode와 Direct mode로 구분하여 치료목적에 따라 주 치료목적 및 보조적 치료 목적으로 적용된 사례에 대해 선량학적 평가를 시행하였고 기존의 라이낙을 이용한 기법과 종양의 발생 부위별 선량학적 분포의 차이를 비교, 분석하였다. 선량 분석은 육종, 뇌척수조사, 유방, 뇌, 췌장, 척추 전이, 상대정맥 증후군, 식도에 토모테라피를 이용한 3차원 입체조형 방사선치료로 치료받는 환자 8명을 대상으로 Helical mode와 Direct mode, 라이낙 기반 치료 기법 사이의 치료 계획 간 비교하였으며, 선량분석은 선량 체적 히스토그램과 등선량 곡선을 이용했다. Direct mode로 치료한 육종, 뇌척수 조사 환자의 경우 체적 길이에 대한 영향을 받지 않아 Junction effect 없는 선량적 결과를 보여주었고, 유방 환자는 D 99%와 D 95%의 선량에서 $49.2{\pm}0.4$ Gy와 $49.9{\pm}0.4$ Gy, V 105%와 V 110%에서 0%로 나타났다. Helical mode로 치료한 뇌, 췌장, 척추 전이 환자에서 dosimetric block을 이용해 정상조직의 선량을 효과적으로 줄일 수 있었고, 상대정맥 증후군 환자는 선량 제한(dose limitation)을 통해 방사선 치료를 재 실시해도 척수선량을 38 Gy이하로 효과적으로 제한할 수 있었다. 식도 환자에서는 기존에 다른 기법과 함께 추가조사 목적으로 사용하여 총 척수선량을 45 Gy 이하로 하고 폐의 V 20%을 20% 이하로 제한할 수 있었다. 토모테라피를 이용한 3차원 입체조형치료는 기존 선형가속기를 이용한 3차원 입체조형 방사선치료에 비해 선량적으로 제한되는 부분을 개선해주고 임상적으로 적절한 선량분포를 구현하는데 효과적인 방법 중의 하나라고 사료된다.

유방암의 접선 세기조절 방사선치료 선량 특성 분석 (Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy)

  • 윤미선;김용협;정재욱;남택근;안성자;정웅기;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.219-228
    • /
    • 2012
  • 기존의 쐐기(wedge) 필터를 사용하는 접선조사(tangential irradiation) 방식의 일반적인 유방암 방사선치료와 동일한 접선 조사야(filed)를 사용하면서 쐐기 필터를 삽입하는 대신 다엽콜리메터의 움직임을 통해 치료부위의 선량분포를 균일하게 형성토록 하는 접선 세기조절 방사선치료(tangential breast Intensity modulated radiotherapy, T-B IMRT)가 유방암치료에 적용되고 있다. 본 연구에서는 T-B IMRT치료계획에서 계산된 선량분포를 기존의 쐐기 필터를 사용한 일반적인 접선조사 방식의 치료계획과 비교하여 치료표적 및 중요장기에서의 선량분포 측면에서 T-B IMRT의 타당성을 살펴보고, 실제 T-B IMRT치료 빔 조사 시 선량 측정 및 치료계획 결과와의 오차 분석을 통해 선량 분포의 정확도를 확인하고자 하였다. 기존의 쐐기필터를 이용한 접선조사 방식으로 치료한 유방암 환자 15명을 대상으로 T-B IMRT치료계획을 세운 후, 계산된 선량분포를 비교, 분석하였다. T-B IMRT치료계획에서 치료표적 부피 내 선량분포의 균일도가 기존의 쐐기를 사용한 접선조사 방식보다 향상된 결과를 보였으며, 주변의 정상조직과 중요장기의 선량을 상대적으로 줄일 수 있음을 확인할 수 있었다. T-B IMRT의 실제 치료조사 시 선량정확도를 분석하기 위해 적합한 팬텀을 사용하여 품질보증(QA) 치료계획을 수립하였다. 원기둥 형태의 아크릴에 이온전리함을 삽입한 형태의 팬텀을 사용하여 치료계획과 실제 치료 빔 조사를 통해 측정된 절대선량 값을 비교하였으며, 평균 오차는 $0.7{\pm}1.4%$로 분석되었다. 이차원 다이오드 검출기 배열장치를 이용한 선량분포의 정확도 분석에서는 치료계획 시 계산된 선량분포와 실제 측정된 선량분포의 gamma evaluation (3%, 3 mm 기준)를 통해 평균 $97.3{\pm}2.9%$의 합격률(pass rate)로 타당성 있는 정확도를 보여주었다. 본 연구를 통해 선량분포 측면에서 기존 쐐기필터를 이용한 접선 조사방식의 방사선치료 대비 T-B IMRT의 장점을 확인할 수 있었고, T-B IMRT에 적합하게 수립된 품질보증 과정을 통해 실제 조사되는 선량의 정확도를 확인할 수 있었다.

Children's Mobile Phone Use and Dosimetry

  • Lee, Ae-Kyoung;Kwon, Jong-Hwa
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.167-172
    • /
    • 2015
  • Research results on possible effects caused by radiofrequency fields in children are limited because most of the studies published so far have focused on adults, rather than children. Mobile phone use is now widespread, even among younger children. If a biological risk due to mobile phone exposure is found, it might be greater in children because their bodies might be more sensitive to radiofrequency energy. The issue of a possible difference in sensitivity between adults and children begins with whether any difference exists physically in terms of electromagnetic absorption. This paper presents a review of recent publications on dosimetric comparisons between children and adults with respect to radiation from mobile phones. The issue of the health effects of mobile phone use is beyond the scope of the present review. Most of the dosimetry research on possible differences in power absorption between children and adults has been based on numerical modeling and analysis. The understanding of the results so far is presented and needed studies are described.

전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가 (Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy)

  • 최우근;전준철;주상규;민병준;박수연;남희림;홍채선;김민규;구범용;임도훈
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.64-71
    • /
    • 2016
  • 삼차원 프린터(3DP)를 이용하여 환자맞춤형 전자선 치료용 볼루스(patient specific customized bolus, PSCB)를 제작하는 절차를 고안하고 제안된 방법으로 제작한 PSCB의 선량 정확도를 평가했다. 치료계획장치에서 치료계획표적용적(PTV)에 적합한 전자선 빔과 조사면 크기를 선택하고 초기 선량계산을 수행했다. 계산된 선량분포를 기반으로 PSCB를 그리고 재계산을 수행했다. 수 차례 반복을 통해 최상의 PSCB를 설계하고 설계된 윤곽자료를 DICOMRT 프로토콜을 이용해 자체 제작한 변환프로그램으로 전송했다. PSCB의 윤곽자료는 자체 변환프로그램을 이용해 3DP에서 인식 가능한 파일(STL 포맷)로 변환한 후 3DP를 이용해 제작했다. PSCB의 유용성을 검증하기 위해 2명의 가상 환자(오목, 볼록 유형)를 생성했고 각각의 환자에 가상의 PTV와 정상장기(OAR)을 생성했다. 3D-PSCB 를 사용했을 때와 사용하지 않았을 때의 선량체적히스토그램(DVH)와 선량 특성을 비교했다. 3D-PSCB 제작의 정확도를 분석하기 위해 필름 선량측정을 통해 선량 정확도를 평가했다. 치료계획 결과와 필름을 이용한 선량분포를 중첩한 후 빔 중심축에서의 심부선량곡선을 구했고 감마분석(3% 선량 오차와 3 mm 거리오차)을 수행 했다. 2명의 가상환자 모두에서 PSCB를 사용한 경우 PTV 선량은 큰 차이를 보이지 않았다. PSCB를 사용할 경우 PSCB를 사용하지 않는 경우에 비해 OAR의 최대 선량, 최소선량, 평균선량은 각각 평균 9.7%, 36.6%, 28.3% 감소했다. 처방선량의 90% 선량($V_{90%}$)을 받는 OAR의 용적은 PSCB를 적용할 경우 약 99% 낮아졌다(14.40 vs $0.1cm^3$). 또한 처방선량의 80% 선량을 받는 OAR 체적도 PSCB를 사용할 경우 약 91% 줄었다(42.6 vs $3.7cm^3$). 감마분석 결과(3%, 3 mm) 오목 및 볼록 볼루스를 적용한 경우 각각 95%, 98% 통과율(pass rate)을 보였다. 3DP를 이용해 PSCB를 제작하는 절차를 정립하고 선량적 정확도를 평가해서 임상적용이 가능한 만족할 만한 결과를 얻었다. 3DP 기술의 빠른 발전에 힘입어 PSCB의 임상적용이 좀 더 쉬워지고 적용대상이 확장될 것으로 생각된다.

Evaluation of Dual-channel Compound Method for EBT3 Film Dosimetry

  • Kang, Sang-Won;Chung, Jin-Beom;Kim, Kyeong-Hyeon;Eom, Keun-Yong;Song, Changhoon;Lee, Jeong-Woo;Cho, Woong;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.16-21
    • /
    • 2017
  • This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.

동적 세기조절방사선 치료 시 선량률 변화에 따른 선량학적엽간격 변화 분석 (Analysis of dosimetric leaf gap variation on dose rate variation for dynamic IMRT)

  • 양명식;박주경;이승훈;김양수;이선영;차석용
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.47-55
    • /
    • 2016
  • 동적 세기조절방사선치료 시 선량률 변화에 따른 다엽콜리메이터의 엽의 위치를 반영하는 선량학적엽간격과 다엽콜리메이터 투과계수 변화를 분석하여 다엽콜리메이터의 정확성을 평가하고자 하였다. Millennium 120 MLC 시스템이 장착된 선형가속기의 6 MV와 10 MV X선으로 물 팬텀의 깊이 10 cm에서 CC13과 FC-65G 전리함을 이용하여 선량률을 200, 300, 400, 500, 600 MU/min으로 변화시켜 선량학적엽간격과 다엽콜리메이터 투과계수를 측정하였다. 400 MU/min의 선량률 기준으로 200, 300, 400, 500, 600 MU/min으로 선량률을 변경하여 선량학적엽간격 값을 측정한 결과, 6 MV의 경우 각각 -2.59, -1.89, 0.00, -0.58, -2.89%의 차이가 나타났고, 10 MV에서는 각각 ?2.52, -1.69, 0.00, +1.28, -1.98%의 차이가 나타났다. 다엽콜리메이터 투과계수는 두 종류의 에너지와 모든 선량률에서 약 ${\pm}1%$ 이내의 범위로 측정되었다. 본 연구는 동적 세기조절방사선치료 시 선량률 변화에 대하여 다엽콜리메이터의 선량학적엽간격과 투과계수 변화를 평가하였다. 선량률 변화에 따라서 다엽콜리메이터의 투과계수의 차이는 미미했지만, 선량학적엽간격의 차이는 큰 것으로 확인하였다. 따라서 동적 세기조절방사선치료 시 임의로 선량률을 변경하면 종양에 전달되는 선량에 많은 영향을 미치므로 치료 중에 선량률을 변화시키지 않는 것이 더욱 정확한 방사선치료 방법이라 사료된다.

  • PDF

진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적 평가 (Dosimetric Evaluation of Amplitude-based Respiratory Gating for Delivery of Volumetric Modulated Arc Therapy)

  • 이창열;김우철;김헌정;박정훈;민철기;신동오;최상현;박승우;허현도
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.127-136
    • /
    • 2015
  • 본 연구의 목적은 진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적인 평가를 하고자 한다. 이 치료를 받은 환자의 호흡 Log 파일을 획득하여 분석하였으며, 4D CT 호흡 형태의 40%~60% 위상 영상 구간 진폭을 기준으로 치료 Log 파일 호흡 진폭의 구간이 4D CT의 진폭 구간과 일치하는 호흡 형태(CBP)와 일치하지 않는 호흡 형태(IBP)로 구분하였다. 상대적인 등선량 분포는 EBT3 필름을 사용하여 측정하였으며, 절대 선량 측정은 PTW $0.6cm^3$ 이온전리함을 이용하여 측정하였다. 감마 인덱스 3%/3 mm을 적용한 환자 1, 2, 3의 CBP 호흡인 경우 각각 93.18%, 91.16%, 95.46%이며, 환자 1, 2, 3의 IBP 호흡인 경우 각각 66.77%, 48.79%, 40.36%으로 분석되었다. 또한 감마 인덱스 2%/2 mm을 적용한 환자 1, 2, 3의 CBP 호흡인 경우 각각 73.05%, 67.14%, 86.85%이며, IBP 호흡인 경우 각각 46.53%, 32.73%, 36.51%으로 분석되었다. 모든 CBP호흡인 경우의 이온전리함 측정값은 치료계획 시스템에서 계산된 값과 평균 3.5% 이내로 일치하였으며, 정적인 팬톰 조사와의 차이는 평균 2.0% 이내로 일치하였다. 환자 3의 IBP 호흡인 경우 이온전리함 측정값과 계산된 값과의 차이가 평균 56%로 큰 차이를 보였다. 이는 4D CT의 진폭 구간과 치료시의 진폭 구간의 차이가 크기 때문인 것으로 사료되며, 4D CT 모의 치료시와 환자 치료시의 진폭의 크기를 일정하게 유지하는 것이 중요하다고 판단된다.

호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석 (Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times)

  • 윤미선;김용협;정재욱;남택근;안성자;정웅기;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.87-92
    • /
    • 2015
  • 호흡연동 래피드아크 치료는 무건운 하중의 선형가속기 갠트리의 회전과 정지의 반복과정에서 갠트리 회전 재시작점의 오차와 다엽조리개의 정확한 움직임 및 갠트리 속도와 같은 래피드아크의 선량정확도를 결정하는 요소들의 오차 가능성으로 인한 선량 오류가 발생할 수 있다. 본 연구에서는 이러한 갠트리의 회전과 정지의 반복적인 동작이 호흡연동 래피드아크 치료의 정확도에 어떠한 영향을 끼치는 지 치료 시 총 회전과 정지 동작 수를 결정하는 빔조사 구간 길이의 변화를 통해 분석하였다. 총 10명의 간암 환자를 대상으로 래피드아크 치료계획을 수립하였고, RPM 호흡연동 장치와 정확한 빔조사 구간 길이를 설정하기 위해 동적 팬텀을 사용하였다. 각 래피드아크 치료계획 당 EPID를 사용한 portal dosimetry delivery quality assurance (DQA) 계획과 이차원 다이오드 검출기배열장치인 MapCHECK2를 사용한 DQA 계획을 수립하여 호흡연동 방사선 치료과정에서 누적된 선량분포의 정확도를 분석하였다. 모든 환자의 호흡주기는 4초로 설정하였고, 수립한 DQA 계획들을 호흡연동 없이 연속적으로 조사하는 것과, 1초의 빔조사 구간과 2초의 빔조사 구간, 총 3가지의 경우에 대해 실제 방사선량 측정과 감마평가를 통해 선량의 정확도를 분석하였다. Portal dosimetry DQA 경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $98.72{\pm}0.82%$ 였고, 1초의 빔조사 구간의 경우 $94.91{\pm}1.64%$, 2초의 빔조사 구간의 경우 $98.23{\pm}0.97%$이었다. MapCHECK2 DQA경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $97.80{\pm}0.91%$였고, 1초의 빔조사 구간의 경우 $95.38{\pm}1.31%$, 2초의 빔조사 구간의 경우 $97.50{\pm}0.96%$였다. 본 연구 결과를 통해 빔조사 구간의 길이가 증가하여 갠트리 정지 동작 수가 감소할수록 호흡연동 래피드아크의 선량 정확도가 증가함을 확인할 수 있었으며, 이러한 특성을 호흡연동 방사선치료 대상 환자의 선정 및 호흡방식에 대한 교육과정에 고려되어야 할 것으로 판단되었다.

Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.