• Title/Summary/Keyword: Dose reduction

Search Result 1,449, Processing Time 0.025 seconds

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis (Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량)

  • Kim, Kye-Sun;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.347-353
    • /
    • 2015
  • The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Adaptive Response Induced by Low Dose Ionizing Raditation in Human Cervical Carcinoma Cells

  • Kim, Jeong -Hee;Lee, Kyung -Jong;Cho, Chul -Koo;Yoo, Seong -Yul;Kim, Tae -Hwan;Ji, Young -Hoon;Kim, Sung -Ho
    • Archives of Pharmacal Research
    • /
    • v.18 no.6
    • /
    • pp.410-414
    • /
    • 1995
  • Adaptive response induced by low dese .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray (1-cGy) followed by high doses of r-ray irradiation (0,1,2,3,5,7 and 9Gy for chlnogenic assay or 1.5Gy for micronucleus assay) with various time intervals. Survival fractions of cells in both low dose-irradiated and unirrated groups were analyzed by clonogenic assay. Surviva fractions of low dose-irradiated in cell survival was maximum when low and high dose irradiation time interval was 4 hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enutained from survival fractions analyzed by clonogenic assay, maximum when low and high dose irradiation time interval was 4hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enumerated in both low dose-irradiated and unirradiated groups. In consiststent with the result obtained from survival fractions analyzed by clonogenic assay, maximum reduction in frquencies of micronuclei was observed when low dose radiation was given 4 hr prior to high response to subsequent high dose .gamma.-ray irradiation in human cervical carcinomal cells. Our data suggest that one of the possible mechanisms of adaptive response induced by low dose rediation is the increase in repair of DNA double strand breaks in low dose radiation-adapted cells.

  • PDF

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

Evaluation of Relative Fluoride Toxicity and Its Impact on Growth, Economic Characters and Fecundity of the Silkworm, Bombyx mori L.

  • Ramakrishna, S.;Nath, B.Surendra;Jayaprakash
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.2
    • /
    • pp.151-159
    • /
    • 2004
  • A detailed evaluation of relative toxicity of fluoride to die 5th instar larvae of PM and NB$_4$D$_2$ races of silkworm and the effects of lethal, sublethal and prevailing levels of fluoride in groundwater on the growth, economic characters and fecundity of the silkworm, Bombyx mori (Lepidoptera: Bombycidae) were studied. The feeding of mulberry, Morus alba leaves treated with lethal and sublethal doses of fluoride to PM and NB$_4$D$_2$ races of silkworms from the beginning of the 5th instar to the end of the feeding period resulted in significant reduction in growth, single cocoon weight, single shell weight, silk index, average filament length, and fecundity when compared to controls. These manges were more pronounced on exposure to lethal dose than sublethal dose and in general, the changes induced by fluoride were more striking in NB$_4$D$_2$ than PM, indicating the greater resistance of PM to higher fluoride levels. Groundwater quality in sericulturally important villages of Karnataka and Andhra Pradesh States has been studied with special reference to the presence of fluoride. On exposure to dose of prevailing levels in the waters of sericulturally important areas, die changes observed on growth, economic characters and fecundity were slightly lower when compared to controls and the decrease was found to be insignificant (P$\geq$0.05). It was concluded that, though minute dose (4.0 ppm) of fluoride did not have any toxic impact, it is toxic at higher concentrations to silkworms.

Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction (뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Effects of Radiation Dose on Mechanical Properties of Resin-Type Neutron Shielding Materials (방사선 조사선량이 수지계 중성자 차폐재의 역학적 성질에 미치는 영향)

  • Cho, Soo-Haeng;Hong, Sun-Seok;Kim, Hwan-Young;Do, Jae-Bum;Ro, Seung-Gy
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.92-98
    • /
    • 1997
  • Effects of radiation dose on mechanical properties such as tensile strength, compressive strength, flexural strength, specific gravity and changes of weight and hydrogen content of epoxy resin-type neutron shielding materials to be used for spent fuel shipping casks have been investigated. At radiation dose up to 0.5MGy, the tensile strength, compressive strength and flexural strength of the shielding materials of KNS-115A, KNS-115B and KNS-115C have been increased with increase in the radiation dose. In contract, these mechanical properties have been decreased at radiation dose above 0.5MGy. The amount of radiation dose on the materials of KNS-115A, KNS-115B and KNS-115C has not resulted in a measurable loss of specific gravity and weight of them, whereas the reduction of hydrogen content has been observed.

  • PDF