• Title/Summary/Keyword: Dose profiles

검색결과 334건 처리시간 0.023초

${\alpha}$-Lipoic acid reduced weight gain and improved the lipid profile in rats fed with high fat diet

  • Seo, Eun-Young;Ha, Ae-Wha;Kim, Woo-Kyoung
    • Nutrition Research and Practice
    • /
    • 제6권3호
    • /
    • pp.195-200
    • /
    • 2012
  • The purpose of this study was to investigate the effects of ${\alpha}$-lipoic acid on body weight and lipid profiles in Sprague-Dawley rats fed a high fat diet (HFD). After 4 weeks of feeding, rats on the HFD were divided into three groups by randomized block design; the first group received the high-fat-diet (n = 10), and the second group received the HFD administered with 0.25% ${\alpha}$-lipoic acid (0.25LA), and the third group received the high-fat diet with 0.5% ${\alpha}$-lipoic acid (0.5LA). The high fat diet with ${\alpha}$-lipoic acid supplemented groups had significantly inhibited body weight gain, compared to that in the HFD group (P < 0.05). Organ weights of rats were also significantly reduced in liver, kidney, spleen, and visible fat tissues in rats supplemented with ${\alpha}$-lipoic acid (P < 0.05). Significant differences in plasma lipid profiles, such as total lipids, total cholesterol, triglycerides, low-density lipoprotein, and high-density lipoprotein, were observed between the HFD and 0.5LA groups. The atherogenic index and the plasma high density lipoprotein-cholesterol/total cholesterol ratio improved significantly with ${\alpha}$-lipoic acid supplementation in a dose-dependent manner (P < 0.05). Total hepatic cholesterol and total lipid concentration decreased significantly in high fat fed rats supplemented with ${\alpha}$-lipoic acid in a dose-dependent manner (P < 0.05), whereas liver triglyceride content was not affected. In conclusion, ${\alpha}$-lipoic acid supplementation had a positive effect on weight gain and plasma and liver lipid profiles in rats.

Photon Beam Commissioning for Monte Carlo Dose Calculation

  • Cho, Byung-Chul;Park, Hee-Chul;Hoonsik Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.106-108
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. Monte Carlo treatment planning requires accurate beam information as input to generate accurate dose distributions. The procedures to obtain this accurate beam information are called "commissioning", which includes accelerator head modeling. In this study, we would like to investigate how much accurately Monte Carlo based dose calculations can predict the measured beam data in various conditions. The Siemens 6MV photon beam and the BEAM Monte Carlo code were used. The comparisons including the percentage depth doses and off-axis profiles of open fields and wedges, output factors will be presented.

  • PDF

Relative Bioavailability and Pharmacokinetics of Newly Designed Cyclosporin A Self-microemulsifying Formulation after Single and Multiple Doses to Dogs

  • Yang, Su-Geun;Shin, Hee-Jong
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권2호
    • /
    • pp.111-115
    • /
    • 2009
  • The pharmacokinetics of cyclosporin A (CsA) after single and multiple oral dosing of new CsA self-micro-emulsifying drug delivery system (SMEDDS) in dogs were estimated. A single dose study was performed following a two-way crossover design against six dogs with reference SMEDDS. For a multiple dose study, three dogs were allocated for each drug, and 100 mg of drug was administered daily for 6 days. Whole blood concentration of CsA was analyzed by radio-immunoassay. Both drug showed identical blood concentration profiles in both studies, and no statistical difference was detected in pharmacokinetic parameters. The relative bioavailabilities of test SMEDDS were 91.4% and 89.1%, respectively, in the single dose study and the last day of multiple dose study. Especially, multiple dose study proved the good relationship between C-0/C-2 and AUC for reference SMEDDS, which is an indispensable part of therapeutic drug monitoring. These results suggest newly formulated CsA SMEDDS possibly shows identical pharmacokinetics and pharmacodynamic behaviors in clinical trials.

몬테카를로 방법에 의한 6 MV 선형가속기의 광자 흡수선량 분포 평가에 관한 연구 (A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method)

  • 강상구;안성환;김종일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권1호
    • /
    • pp.43-50
    • /
    • 2011
  • 본 연구에서는 Geant4 시뮬레이터를 이용하여 Varian 2100C/D 선형가속기의 헤드 부분과 다엽콜리메이터를 모델링한 후 6 MV 광자 선속에 대해 선량분포 평가의 기본이 되는 물팬텀($50{\times}50{\times}50\;cm^3$) 내에서의 심부선량백분율(Percentage depth dose)과 측면선량(lateral dose)에 대해 검출기를 이용한 측정 결과와 시뮬레이션 결과를 비교 평가하였다. 시뮬레이션은 두 단계로 나누어 진행하였다. 첫 번째 단계에서 타겟을 통해 나오는 광자의 에너지 스펙트럼을 측정하였다. 다음 단계에서 셈플링한 에너지 스펙트럼에 따라 광자를 직접 팬텀에 조사하는 방식으로 수행하였다. 실험 결과 $5{\times}5 \;cm^2$$10{\times}10\;cm^2$ 조사야에서의 심부선량백분율과 16 mm, 50 mm, 100 mm에서 측정한 측면 선량 모두 측정값과 비교하여 2% 이내의 오차를 보여 임상적으로 허용범위 안의 오차를 확인하였고 다엽콜리메이터의 정확도는 1 mm 이내의 오차를 확인 할 수 있었다. 본 연구의 연구 결과를 기초로 한 계산적 방법은 오차가 많이 발생하는 비균질성 조직 내에서의 선량분포 연구와 DICOM 데이터를 적용한 선량 계산 시뮬레이션 응용에서 활용하기 위해 선행되어야 하는 기초 자료로서 활용가치가 있다고 판단된다.

茵蔯蒿湯의 랫드에서의 單回投與毒性試驗 (Single dose toxicity study of Injinhotang in rat)

  • 김상찬;변준철;박종현;지선영;변성희;이형식
    • 한방안이비인후피부과학회지
    • /
    • 제14권2호
    • /
    • pp.118-124
    • /
    • 2001
  • The single dose toxicity of Injinhotang, a herbal drug for treatment of hepatic injuries. was evaluated in Sprague-Dawley rats. Injinhotang was once administered to both sexes of rats at the dose levels of 2000, 1000, 500, 250 and 125 mg/kg for oral route. After single administration, clinical signs were observed every day for 14 days and body weights were measured 5 times including initial measurement on day 0 (the days of administration). When observation period was over, the animals were sacrificed and macroscopic examination of major organs was conducted. In addition, the histopathological profiles of these major organs were also conducted. Neither significant clinical signs nor death after administration was observed during the observation periods except for soft feces or diarrhea. In addition, no abnormal necropsy findings, changes of body weight and histopathological profiles were observed at terminal necropsy in both sexes. From these results, it is considered that $LD_{50}$ of Injinhotang is over 2000 mg/kg in oral administration in both sexes of rats.

  • PDF

Safety Evaluation of Kyungokgo-gamibang Administration Based on Hematological, Biochemical, Protein, and Lipid Profiles in Dogs

  • Song, Doo-won;Lee, Ga-won;Ro, Woong-bin;Kim, Heyong-seok;Kang, Hyun-min;Kim, Jong-won;Park, Soo-bin;Moon, Yang-seon;Na, Chang-su;Park, Hee-myung
    • 한국임상수의학회지
    • /
    • 제38권1호
    • /
    • pp.7-15
    • /
    • 2021
  • Kyungokgo-gamibang, Kyungokgo with Iksuyongjingo and Sparassis crispa, is a traditional Korean medicine used for restorative effects. This study aimed to evaluate the safety of Kyungokgo-gamibang in healthy beagle dogs. In the single-dose oral toxicity study, three beagle dogs were orally administered 2,000, 1,000, and 500 mg/kg of Kyungokgo-gamibang and were observed for 14 days. In the repeated-dose oral toxicity study, nine healthy dogs were orally administered 0.2g/kg of Kyungokgo-gamibang (n = 3, low-dose group), 1 g/kg of Kyungokgo-gamibang (n = 3, high-dose group), or normal saline (n = 3, control group) twice a day for 8 weeks. The hematological, serum biochemical, urine, protein, and lipid profiles were evaluated to investigate the adverse effects of the Kyungokgo-gamibang. During the study period, the dogs demonstrated no clinical signs and the hematological, serum biochemical, urine, protein, and lipid analyses revealed unremarkable findings. The study results suggest that Kyungokgo-gamibang can be safely administered to dogs without any adverse effects.

렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교 (Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique)

  • 허병익
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 감마나이프 방사선수술(GKRS)의 높은 정밀도와 정확성은 치료 성공을 위한 기본 요건이다. 방사선의 급격한 감소와 함께 정교한 방사선 전달 및 선량 기울기가 임상적으로 적용되어야 하므로 방사선량 측정 및 기하학적 정확성을 보장하고 감마나이프 방사선수술에서 발생할 수 있는 모든 위험 요인을 줄이기 위해서는 전용 정도관리(QA) 프로그램이 필요하다. 본 연구에서는 독립적인 검증 프로그램 가변 타원체 모형화기술(Variable Ellipsoid Modeling Technique: VEMT)을 적용해서 감마나이프 치료계획 시스템 렉셀 감마플랜의 알고리즘에 사용된 단일 샷 선량 분포의 정확성을 검증하였다. 감마나이프 퍼펙션(PFX)에 장착한 직경 160 mm의 구형 ABC 팬텀에 조사한 단일 샷의 선량 분포를 평가했다. 단일 샷의 조사는 ABC 팬텀의 중심으로 향하게 하여 x, y 및 z 축을 따라 4, 8 및 16 mm 크기의 시준기 배치가 고려되었다. 감마나이프 방사선수술에서 사용되는 감마나이프 퍼펙션 치료계획 시스템은 렉셀 감마플랜(LGP) 버전 10.1.1이 사용되었다. VEMT의 검증을 통해서 감마나이프 방사선수술의 정확성은 배가 될 것이다. 그래서 VEMT 검증 후 감마나이프 방사선수술의 정확성과 정밀성을 토대로 임상 적용이 최종적으로 수행되어야 한다. 특히 환자의 머리가 직경 160mm의 구형으로 시뮬레이션된 조건에서 50% 등선량 높이 수준의 너비, 즉 최대반값폭(FWHM)이 검토되었다. VEMT를 통해 예측된 x, y, z 축의 선량 분포에 관한 모든 데이터는 4 mm 및 8 mm 시준기 배치에 대해 z 축을 따라 최대반값폭과 반그늘(PENUMBRA)의 약간의 차이점을 제외하고는 사양 내(등선량 50%에서 1 mm 이내)에서 LGP의 선량 분포와 훌륭하게 일치했다. 최대반값폭의 최대 불일치는 모든 시준기 배치에서 2.3% 미만이었다. 반그늘의 최대 불일치는 z 축을 따라 8 mm 시준기에 대해서 0.07 mm로 주어졌다. VEMT와 LGP로 얻은 선량 분포에서 최대반값폭과 반그늘의 차이는 감마나이프 방사선수술에서 임상적 유의성을 부여하기에는 너무 작았다. 이 연구의 결과는 전 세계 감마나이프 방사선수술에 관련된 의학물리학자를 위한 참고 자료로 활용될 수 있으리라 사료된다. 따라서 우리는 LGP의 결과물에 대한 독립적인 검증방법 VEMT를 포함하는 정기 예방정비 프로그램을 통해 결정된 모든 시준기 배치에 대한 선량 분포의 유효성을 확인하고 감마나이프 방사선수술 환자에게 임상적으로 완벽한 치료를 보장할 수 있다. 그래서 VEMT의 활용은 시스템을 안전하게 검증하고 운영할 수 있는 정도관리의 한 부분이 될 것으로 기대한다.

Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인 (The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.3-17
    • /
    • 1996
  • 방사선 치료분야에서 선량 보상체가 널리 이용되고 있으나, 그 보상효과에 대한 확실한 검증 방법은 알려진 바가 거의 없다. 본 연구에서는 Missing Tissue 뿐 아니라, Internal Tissue Inhomogeneity 까지 고려한 3차원 보상체를 제작하고, Exit Beam Dose Profile의 측정값과 본 연구에서 고안한 방법으로 기대값을 구해 비교함으로써 보상체의 성능을 평가하고자 하였다. 환자정보는 CT Simulator를 사용하여 얻었고, 보상체 정보는 Render Plan 3-D Planning System을 통해 얻었다. Computer Controlled Milling Machine으로 알루미늄 보상체를 제작해서 보상체가 있는 경우와 없는 경우의 선량 프로파일을 측정하여 비교하였다. 측정은 폴리스티렌 팬톰 사이에 필름을 삽입하여 팬톰 내에서의 실제 선량 분포를 구하고, 필름 카셋트를 이용해서 Exit Beam Dose Profile 을 동시에 얻었다. Oblique Beam, Parallel Opposing Beam, Inhomogeneus Human Phantom에 대해 제작된 보상체가 각각 선량보상 효과가 잘 나타남을 볼 수 있었고, 이 연구에서의 성능확인 방법을 통해 보상체의 성능을 확인할 수 있었다.

  • PDF

Dose Calculation of Photon Beam with Wedge Filter for Radiation Therapy Planning System

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.41-41
    • /
    • 2003
  • Purpose: Even if the wedge filter is widely used for the radiation therapy to modify the photon beam intensity, the wedged photon beam dose calculation is not so easy. Radiation therapy planning systems (RTPS) have been used the empirical or semi-analytical methods such as attenuation method using wedge filter parameters or wedge filter factor obtained from measurement. However, these methods can cause serious error in penumbra region as well as in edge region. In this study, we propose the dose calculation algorithm for wedged field to minimize the error especially in the outer beam region. Materials and Method: Modified intensity by wedge filter was calculated using tissue-maximum ratio (TMR) and scatter-maximum ratio (SMR) of wedged field. Profiles of wedged and non-wedged direction was also used. The result of new dose calculation was compared with measurement and the result from attenuation method. Results: Proposed algorithm showed the good agreement with measurement in the high dose-gradient region as well as in the inner beam region. The error was decreased comparing to attenuation method. Conclusion: Although necessary beam data for the RTPS commissioning was increased, new algorithm would guarantee the improved dose calculation accuracy for wedged field. In future, this algorithm could be adopted in RTPS.

  • PDF

Induction of SOS Genes by a Low Dose of Gamma Radiation, 10 Gy, in Salmonella enterica Serovar Typhimurium

  • Lim, Sangyong;Joe, Minho;Seo, Hoseong;Kim, Dongho
    • 방사선산업학회지
    • /
    • 제7권2_3호
    • /
    • pp.109-113
    • /
    • 2013
  • In a previous study, a relatively high dose of gamma radiation (1 kGy) did not fully induce typical SOS genes such as sulA, recA, recN, and din in Salmonella Typhimurium (S. Typhimurium) (Lim et al. 2008, Gene expression profiles following high-dose exposure to gamma radiation in Salmonella enterica serovar Typhimuium. J. Radiat. Ind. 3:111-119). In this study, we examined changes in the transcriptional repertoire of S. Typhimurium after a dose of 10 Gy using DNA microarrays. It was found that more than half (~65%) of the 26 up-regulated genes belong to the SOS regulon: ten genes are typical SOS genes, and seven genes are Salmonella prophage genes, which are known to be activated by LexA cleavage. Among 29 down-regulated genes, the function of five genes with the most decreased expression is associated with carbohydrate transport and energy production. This suggests that upon exposure to gamma radiation cells may cease growing by reducing the metabolic activity, and repair DNA damage using a DNA repair system such as the SOS response system. The difference in expression of the SOS genes between a high (1 kGy) and low (10 Gy) dose of radiation shows the possibility that cells may opt for one of multiple regulatory circuits in response to the specific gamma radiation dose.