• 제목/요약/키워드: Dose conversion

검색결과 244건 처리시간 0.021초

Protective Effect of Physostigmine and Neostigmine against Acute Toxicity of Parathion in Rats

  • Jun, Jung-Won;Kim, Young-Chul
    • Archives of Pharmacal Research
    • /
    • 제14권4호
    • /
    • pp.330-335
    • /
    • 1991
  • The effects of physostigmine and neostigmine on the parathin induced toxicity were examined in adult female rats. Physostigmine $(100\;{\mu}g/kg,\;ip)$ or neostigmine $(200\;{\mu}g/kg,\;ip)$ inhibited acetylcholinesterase (AChE) and cholinesterase (ChE) activities in blood, brain and lung when the enzyme activity was measured 30 min after the treatment. At the doses of two carbamates equipotent on brain AChE, neostigmine showed greater inhibition on peripheral AChE/ChE. The enzyme activity returned to normal in 120 min following the carbamates except in the lung of rats treated with neostigmine. Carbamates administered 30 min prior to parathion (2 mg/kg) antagonized the inhibition of AChE/ChE by parathion when the enzyme activity was measured 2 hr following parathion. Neostigmine showed greater protective effect on peripheral AChE/ChE. The effect of either carbamate on AChE/ChE was not significant 2 hr beyond the parathion treatment. Carbamates decreased the mortality of rats challenged with a lethal dose of parathion (4 mg/kg, ip) either when treated alone or in combination with atropine (10 mg/kg, ip). Lethal action of paraoxon (1.5 mg/ks ip), the active metabolite of parathion was also decreased by the carbamate treatment indicating that the protection was not mediated by competitive inhibition of metabolic conversion of parathion to paraoxon. The results suggest that carbamylation of the active sites may not be the sole underlying mechanism of protection provided by the carbamates.

  • PDF

Effects of surface modification of $Nafion^{(R)}$ Membrane on the Fuel Cell Performance

  • Prasanna, M.;Cho, E.A.;Ha, H.Y.;Hong, S.A.;Oh, I.H.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 추계 학술발표회 논문집
    • /
    • pp.133-138
    • /
    • 2004
  • Proton exchange membrane fuel cell (PEMFC) is considered as a clean and efficient energy conversion det ice for mobile and stationary applications. Anions all the components of the PEMFC, the interface between the electrolyte ,and electrode catalyst plays an important role in determining tile cell performance since the electrochemical reactions take place at the interface in contact with tile reactant gases. Therefore, to increase the interface area and obtain a high-performance PEMFC, surface of the electrolyte membrane was roughened by Ar$^{+}$ beam bombardment. The results imply that by modifying surface of the electrolyte membrane, platinum loading can be reduced significantly without performance loss. To optimize the surface treatment condition, effects of ion dose density on characteristics of the membrane/electrode interface were examined by measuring the cell performance, impedance spectroscopy, and cyclic voltammograms. Surface of the modified membranes were characterized using scanning electron microscopy and FT-IR.R.

  • PDF

방사선에 대한 CdTe/CdS 태양전지 특성 검토 (Property of CdTe/CdS Solar Cells on Gamma-irradiation)

  • 김지유;김화정;박해준;하장호
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.17-22
    • /
    • 2014
  • In this study, we prepared CdTe/CdS solar cells using a thermal vacuum evaporation method. In particular, $CdCl_2$ treatment was attempted using this same method at $400^{\circ}C$ for 30 min. The prepared CdTe/CdS solar cells were investigated using Fouier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FE-SEM), and a solar simulator system including light absorption properties, morphological properties, and power conversion efficiency (PCE). In addition, we investigated the gamma-irradiation treatment at dose rates of 0 Gy, 500 Gy, 1 kGy, 10 kGy, and 30 kGy. The characteristics of gamma-irradiation treatment were studied based on the same method described above. In particular, it showed increased values as 0.826% higher than the non-irradiation of 0.448% from PCE analysis.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

방사성폐기물 처분시설에서 생태계 모델의 입력데이터 선정에 대한 고찰 (Considerations on Screening for the Input Data of the Biosphere Model in the Radioactive Waste Disposal Facility)

  • 정미선;박동국;김수진;정강일
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.209-217
    • /
    • 2023
  • The biosphere has important function in the safety assessment of a radioactive waste disposal facility. A biosphere model in the safety assessment needs various input data that contain significantly inherent uncertainties. This paper reviews the effects of the input data on the radiological impact assessment from main radionuclides such as 14C and 99Tc in the biosphere model. In addition, it is confirmed that the safety criteria is met, when the conservative input data for the intake rate, soil to plant concentration ratio, and distribution coefficients of the radionuclides are applied and probabilistic analysis are conducted in the biosphere model. Nevertheless, it is required to generate site-specific input data for the confidence building and reduce excessive conservatism in the biosphere model.

양극의 경사각 효과에 따른 조사야 X-선 강도 분포 (Distribution of X-ray Strength in Exposure Field Caused by Heel Effect)

  • 장근조;김남훈;이준행;이상복
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.223-229
    • /
    • 2011
  • X선은 X선관 내 음극측 전자(electron)를 빠른 속도로 가속시킨 다음 진행하는 전자의 흐름을 저지극(target)에서 차단시킬 때 에너지의 변환을 일으켜 발생한다. 가속된 고속의 전자가 저지면에 충돌하는 실제면적을 실초점(actual focal spot)이라 하고, 실초점의 크기를 X선이 나오는 방향인 중심선(central ray)측에서 관측할 경우 축소되어 작게 보이는데 이때의 초점을 실효초점(effective focal spot)이라고 한다. X선관 방사각에 따라 음극 측의 강도가 양극 측 보다 높게 나타나 X선 강도가 균등하지 않다. 이러한 효과를 경사각 효과(heel effect)라고 하며, 경사각 효과로 인하여 환자가 받는 피폭의 정도는 양극의 각도, 즉 실효초점의 크기에 따라 달라지게 된다. 본 논문에서는 실효초점의 크기와 그에 따른 환자 피폭선량의 상관관계를 알아보고 실효초점의 크기에 따른 균질선량 분포를 위한 효과적인 조사야를 제시하고자 한다. 결론적으로 초점크기에 따라서 평균적으로 -8cm ~ 0cm 범위에서 효과적인 조사야 범위를 찾을 수 있었고, 평균 선량률은 0.019 R/min이 나왔다. 이 범위를 이용하면 환자에게는 적은 피폭선량으로 균등한 흑화도 및 해상력을 가진 영상을 얻을 수 있을 것이다.

경시적 자료의 주의력 결핍 과잉행동 장애를 종점으로 한 납의 벤치마크 용량 하한 도출 (Derivation of a benchmark dose lower bound of lead for attention deficit hyperactivity disorder using a longitudinal data set)

  • 이주형;김시연;하미나;권호장;김병수
    • 응용통계연구
    • /
    • 제29권7호
    • /
    • pp.1295-1309
    • /
    • 2016
  • 본 연구의 목적은 아동 건강에 미치는 환경의 영향을 평가하기 위하여 우리나라 환경부에서 구축한 경시적 자료인 CHEER 자료를 바탕으로 납의 벤치마크 용량 하한(BMDL)을 도출하여 Kim 등 (2014)의 결과를 재현하는 것이다. 본 연구에서는 CHEER 자료의 2005년 동집단을 사용하였는데, 벌점화 선형 스플라인을 이용한 변환공식으로 2005년 동집단의 ADHD 평가 척도를 통일하고, 경시적 자료의 특성을 반영한 두 개의 선형혼합모형을 구축하였다. 이후 구축된 모형을 바탕으로 혈중 납 농도의 BMDL을 도출하였다. 이 과정에서 Kim 등 (2014)에서 발견한 ADHD 점수의 평균으로의 회귀 현상이 재확인되었고, 2005년 동집단과 2006년 동집단의 분포 상의 특징적 차이가 발견되었다. 결과적으로 이 차이를 감안했을 때, Kim 등 (2014)과 일치적인 결과를 얻을 수 있었다.

Prostatic Artery Embolization for Lower Urinary Tract Symptoms via Transradial Versus Transfemoral Artery Access: Single-Center Technical Outcomes

  • Ryun Gil;Dong Jae Shim;Doyoung Kim;Dong Hwan Lee;Jung Jun Kim;Jung Whee Lee
    • Korean Journal of Radiology
    • /
    • 제23권5호
    • /
    • pp.548-554
    • /
    • 2022
  • Objective: To evaluate the safety and feasibility of prostatic artery embolization (PAE) via transradial access (TRA) compared with transfemoral access (TFA). Materials and Methods: This retrospective study included 53 consecutive men with lower urinary tract symptoms (LUTS) who underwent PAE between September 2018 and September 2021. Thirty-one patients (mean age ± standard deviation: 70.6 ± 8.4 years) were treated with TFA, including 14 patients treated before adopting TRA. Since December 2019, TRA has also been attempted with the procedure's selection criteria of patent carpal circulation and a height ≤ 172 cm, with 22 patients treated via TRA (69.1 ± 9.6 years). Parameters of technical success (defined as successful bilateral embolization), clinical success (defined as LUTS improvement), procedural time, radiation dose, and adverse events were compared between the two groups using the Fisher's exact test, independent sample t test, Wilcoxon signed-rank test, or Mann-Whitney test. Results: All patients received at least one-side PAE. Technical success of PAE was achieved in most patients (TRA, 21/22; TFA, 30/31; p > 0.999). No technical problem-related conversion from TRA to TFA occurred. The clinical success rate was 85% (11/13) in patients with TRA, and 89% (16/18) in patients with TFA for follow-up > 2 weeks post-PAE (median, 3 months) (p > 0.999). The median procedure time was similar in both groups (TRA, 81 minutes vs. TFA, 94 minutes; p = 0.570). No significant dose differences were found between the TRA and TFA groups in the dose-area product (median Gycm2, 95 [range, 44-255] for TRA and 84 [34-255] for TFA; p = 0.678) or cumulative air kerma (median mGy, 609 [236-1584] for TRA and 634 [217-1594] for TFA; p = 0.551). No major adverse events occurred in either of the groups. Conclusion: PAE via TRA is a safe and feasible method comparable to conventional TFA. It can be safely implemented by selecting patients with patent carpal circulation and adequate height.

전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가 (Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy)

  • 최우근;전준철;주상규;민병준;박수연;남희림;홍채선;김민규;구범용;임도훈
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.64-71
    • /
    • 2016
  • 삼차원 프린터(3DP)를 이용하여 환자맞춤형 전자선 치료용 볼루스(patient specific customized bolus, PSCB)를 제작하는 절차를 고안하고 제안된 방법으로 제작한 PSCB의 선량 정확도를 평가했다. 치료계획장치에서 치료계획표적용적(PTV)에 적합한 전자선 빔과 조사면 크기를 선택하고 초기 선량계산을 수행했다. 계산된 선량분포를 기반으로 PSCB를 그리고 재계산을 수행했다. 수 차례 반복을 통해 최상의 PSCB를 설계하고 설계된 윤곽자료를 DICOMRT 프로토콜을 이용해 자체 제작한 변환프로그램으로 전송했다. PSCB의 윤곽자료는 자체 변환프로그램을 이용해 3DP에서 인식 가능한 파일(STL 포맷)로 변환한 후 3DP를 이용해 제작했다. PSCB의 유용성을 검증하기 위해 2명의 가상 환자(오목, 볼록 유형)를 생성했고 각각의 환자에 가상의 PTV와 정상장기(OAR)을 생성했다. 3D-PSCB 를 사용했을 때와 사용하지 않았을 때의 선량체적히스토그램(DVH)와 선량 특성을 비교했다. 3D-PSCB 제작의 정확도를 분석하기 위해 필름 선량측정을 통해 선량 정확도를 평가했다. 치료계획 결과와 필름을 이용한 선량분포를 중첩한 후 빔 중심축에서의 심부선량곡선을 구했고 감마분석(3% 선량 오차와 3 mm 거리오차)을 수행 했다. 2명의 가상환자 모두에서 PSCB를 사용한 경우 PTV 선량은 큰 차이를 보이지 않았다. PSCB를 사용할 경우 PSCB를 사용하지 않는 경우에 비해 OAR의 최대 선량, 최소선량, 평균선량은 각각 평균 9.7%, 36.6%, 28.3% 감소했다. 처방선량의 90% 선량($V_{90%}$)을 받는 OAR의 용적은 PSCB를 적용할 경우 약 99% 낮아졌다(14.40 vs $0.1cm^3$). 또한 처방선량의 80% 선량을 받는 OAR 체적도 PSCB를 사용할 경우 약 91% 줄었다(42.6 vs $3.7cm^3$). 감마분석 결과(3%, 3 mm) 오목 및 볼록 볼루스를 적용한 경우 각각 95%, 98% 통과율(pass rate)을 보였다. 3DP를 이용해 PSCB를 제작하는 절차를 정립하고 선량적 정확도를 평가해서 임상적용이 가능한 만족할 만한 결과를 얻었다. 3DP 기술의 빠른 발전에 힘입어 PSCB의 임상적용이 좀 더 쉬워지고 적용대상이 확장될 것으로 생각된다.