• Title/Summary/Keyword: Dose calculation

Search Result 522, Processing Time 0.021 seconds

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF